ADJUSTMENTS
Always disconnect the appliance from the electricity main before making any adjustments. All seals must be replaced by the technician at the end of any adjustments or regulations.
Our burners do not require primary air adjustment.
9) TAPS
"Reduced rate" adjustment
-Switch on the burner and turn the relative knob to the "Reduced rate" position (small flame fig.12).
-Remove knob "M" (fig. 12) of the tap, which is simply pressed on to its rod.
-Insert a small screwdriver "D" into hole "C" (fig. 12) and turn the throttle screw to the right or left until
the burner flame has been adequately regulated to the "Reduced rate" position.
Check that the flame does not go out when the knob is sharply switched from the "Full on" to the "Reduced rate" position.
It is understood that only burners operating with G20 gas should be subjected to the above mentioned adjustments. The screw must be fully locked when the burners operate with G30 or G31 (turn clockwise).
FIG. 12
9