Teka EX/60 4G AI FUND manual Servicing, Replacing HOT Plate Parts, Greasing the taps see

Page 11

SERVICING

Always disconnect the appliance from the electricity and gas mains before proceeding with any servicing operation.

11) REPLACING HOT PLATE PARTS

Replacement of the components housed inside the appliance: remove the trivets and the burners from the upper part of the working table; remove the fixing screws "V" of the burner (fig. 14) and the knobs fixed by pressure with the hans, in order to take off the appliance.

After having carried out the above listed operations, the burners (fig.15), taps (fig. 16) and electrical components can all be replaced (fig. 17). It is advisable to change seal "D" whenever a tap is replaced to ensure a perfect tightness.

Greasing the taps (see fig. 18 - 19)

If a tap becomes stiff to operate, it must be immediately greased in compliance with the following instructions:

-Remove the tap.

-Clean the cone and its housing using a cloth soaked in diluent.

-Lightly spread the cone with the relative grease.

-Fit the cone back in place, operate it several times and then remove it again. Eliminate any excess grease and check that the gas ducts have not become clogged.

-Fit all parts back in place, complying with the demounting order in reverse.

-Ceck the tightness by using soapy water. The use of the flame is prohibited.

To facilitate the servicing technician's task, here is a chart with the types and sections of the powering cables and the ratings of the electrical components.

FIG. 14

FIG. 15

FIG. 16

FIG. 17

FIG. 18

FIG. 19

11

Image 11
Contents Instructions Manual Description of the HOT Plates Burners HOW to USE the BurnersUSE AIR Inlet see Installation Chapter Paragraphs 5 HOT Plate CleaningFixing the HOT Plate InstallationTechnical Information For the Installer Installing the HOT PlateGAS Connection Important Installation InstructionsRoom Ventilation Location and AerationElectrical Connection Taps AdjustmentsOur burners do not require primary air adjustment Reduced rate adjustmentBurner Arrangement on the HOT Plate ConversionsReplacing the Injectors Greasing the taps see ServicingReplacing HOT Plate Parts Cable Types and Sections Technical Data on the Data Label Mark Model Series Technical Assistence and Spare PartsKüchentechnik