Lennox International Inc Merit CBX25UH Series, Lennox Air Handler Maintenance, Cabinet Insulation

Page 13

second heat sequencer can be connected with the first sequencer to W1 on the thermostat. They may also be connected to a second heating stage W2 on the thermostat subbase.

EMERGENCY HEAT (HEATING HEAT PUMP)

If the selector switch on the thermostat is set to the emergency heat position, the heat pump will be locked out of the heating circuit, and all heating will be electric heat (if applicable). A jumper should be placed between W2 and E on the thermostat subbase so that the electric heat control will transfer to the first‐stage heat on the thermostat. This will allow the indoor blower to cycle on and off with the electric heat when the fan switch is in the AUTO position.

Maintenance

IMPORTANT

Do not operate system without a filter. A filter is required to protect the coil, blower, and internal parts from exces­ sive dirt and dust. The filter is placed in the return duct by the installer.

SInspect air filters at least once a month and replace or clean as required. Dirty filters are the most common cause of inadequate heating or cooling performance.

SReplace disposable filters. Cleanable filters can be cleaned by soaking in mild detergent and rinsing with cold water.

SInstall new/clean filters with the arrows on the side pointing in the direction of airflow. Do not replace a cleanable (high velocity) filter with a disposable (low velocity) filter unless return air system is properly sized for it.

SIf water should start coming from the secondary drain line, a problem exists which should be investigated and corrected. Contact a qualified service technician.

Cabinet Insulation

IMPORTANT

DAMAGED INSULATION MUST BE REPAIRED OR REPLACED before the unit is put back into operation. In­ sulation loses its insulating value when wet, damaged, separated or torn.

Matt‐ or foil-faced insulation is installed in indoor equipment to provide a barrier between outside air conditions (surrounding ambient temperature and humidity) and the varying conditions inside the unit. If the insulation barrier is damaged (wet, ripped, torn or separated from the cabinet walls), the surrounding ambient air will affect the inside surface temperature of the cabinet. The temperature/humidity difference between the inside and outside of the cabinet can cause condensation on the inside or outside of the cabinet which leads to sheet metal corrosion and subsequently, component failure.

REPAIRING DAMAGED INSULATION

Areas of condensation on the cabinet surface are an indication that the insulation is in need of repair.

If the insulation in need of repair is otherwise in good condition, the insulation should be cut in an X pattern, peeled open, glued with an appropriate all-purpose glue and placed back against the cabinet surface, being careful to not overly compress the insulation so the insulation can retain its original thickness. If such repair is not possible, replace the insulation. If using foil‐faced insulation, any cut, tear, or separations in the insulation surface must be taped with a similar foil-faced tape.

GLUE -make sure there is full coverage of glue on the metal or insulation so there are no areas where air pockets may form which can lead to sweating.

1.CUT INSULATION IN X PATTERN

2.APPLY GLUE

3.PRESS GLUED TABS AGAINST CABINET

Figure 15. Repairing Insulation

Page 13

CBX25UH SERIES

Image 13
Contents Shipping and Packing List Table of ContentsGeneral AIR Flow CBX25UH Unit Dimensions inches mmRequirements Installation ClearancesRefrigerant Metering Device InstallationUpflow Application Horizontal ApplicationsRemove two screws securing the blow-off prevention RIGHT-HAND AIR DischargeOverflow Drain Line Condensate DrainDuct System and Filters Install Condensate DrainSloping the Drain Test Condensate DrainInstalling Duct System Connecting Refrigerant LinesSealing the Unit Volt Conversion Electrical ConnectionsChange Blower Speed Airflow Cooling Blower SpeedChanging Blower Speed Operation Check-out ProceduresRepairing Damaged Insulation MaintenanceCabinet Insulation Emergency Heat Heating Heat PumpStart-Up and Performance Checklist Upflow Configuration Start-Up and Performance Checklist Horizontal Configuration

Merit CBX25UH Series, Lennox Air Handler specifications

Lennox International Inc is a leading provider of innovative HVAC systems, and among its standout products is the Merit CBX25UH Series, an advanced air handler designed to enhance indoor comfort while ensuring energy efficiency. This series is specifically designed for use with the Lennox cooling and heating systems, making it an ideal choice for homeowners seeking versatile climate control solutions.

One of the primary features of the Merit CBX25UH Series is its multi-position installation capability, allowing it to be configured for upflow, downflow, or horizontal airflow. This flexibility makes it suitable for a wide range of home layouts and needs. The series is designed for use with a variety of Lennox outdoor units, ensuring seamless integration into existing HVAC systems.

The air handler is equipped with a high-efficiency blower motor that optimizes airflow, enhancing indoor comfort while minimizing energy consumption. This variable-speed blower motor not only operates quietly but also adjusts airflow based on the specific heating or cooling demands of the home. This feature significantly improves energy efficiency, helping homeowners save on utility bills while reducing their environmental impact.

Another key technology in the Merit CBX25UH Series is its SmartLynx™ communicating technology, which allows for efficient communication between the air handler and other HVAC components. This advanced communication ensures that the system operates at peak performance, providing consistent and reliable heating and cooling throughout the space.

The CBX25UH also boasts a durable cabinet that offers excellent insulation, minimizing energy loss and enhancing overall system efficiency. The cabinet's design reduces noise levels, contributing to a more peaceful indoor environment. Additionally, the air handler features a robust filtration system that helps maintain indoor air quality by capturing dust and allergens, ensuring a healthier living space.

Lastly, the Merit CBX25UH Series is backed by Lennox’s renowned reliability and quality. Homeowners can have peace of mind knowing they are investing in a product designed to deliver dependable performance for years to come. Overall, the Merit CBX25UH Series is a top choice for those seeking a powerful, efficient, and flexible air handling solution within their HVAC system.