Lennox International Inc Lennox Air Handler Condensate Drain, Overflow Drain Line

Page 6

HORIZONTAL RIGHT

HORIZONTAL LEFT

 

REMOVE 2 SCREWS

(FACTORY DEFAULT)

 

SECURING BLOW OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PREVENTION BRACKET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROTATE BRACKET TO THIS

POSITION AND REINSTALL

Figure 8. Blow-Off Prevention Plate

Condensate Drain

IMPORTANT

On units of this type, where the blower “draws” rather than “blows” air through the coil, traps must be installed in the con­ densate drain lines (primary and auxiliary, if used). Traps prevent the blower from drawing air through the drain lines into the air supply.

ABOVE

FINISHED

SPACE?

NO

OVERFLOW DRAIN LINE

ALWAYS RUN AN OVERFLOW DRAIN LINE. IF NOT POSSIBLE TO ROUTE OVERFLOW DRAIN LINE, INSTALL LOW VOLTAGE OVERFLOW SWITCH KIT. WIRE KIT TO SHUT DOWN COMPRESSOR PER INSTRUCTIONS.

LENNOX #

X3169

COMPACT OVERFLOW SWITCH WITH 3/4” FEMALE SLIP INLET AND MALE ADAPTER, TWO PART DESIGN FOR USE WHERE OBSTRUCTIONS PREVENT DIRECT THREADING

 

VENT MUST EXTEND

 

 

 

ABOVE HEIGHT OF

 

 

 

COIL DRAIN PAN BY

 

 

TWO INCHES (51MM)

VENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLEAN OUT

 

 

 

PRESS IN

 

 

(DO NOT GLUE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR HANDLER DRAIN PAN

MAIN

1” X 3/4” X 3/4”

 

DRAIN

REDUCING

OVERFLOW

 

TEE WITH

 

PLUG

DRAIN

 

 

 

YES

NOTE — WHEN A AIR HANDLER IS LOCATED ABOVE A FINISHED SPACE THE SECONDARY DRAIN PAN MUST HAVE A LARGER FOOTPRINT THAN THE AIR HANDLER.

SECONDARY

DRAIN PAN

WHEN A COIL IS LOCATED ABOVE A FINISHED SPACE, A 3/4” (19.1MM) SECONDARY DRAIN LINE MUST BE:

SCONNECTED TO SECONDARY DRAIN PAN OR

SCONNECTED TO THE OVERFLOW DRAIN OUTLET OF THE AIR HANDLER DRAIN PAN.

LENNOX1 P-TRAP

49P66, J-TRAP #

91P90 OR ANY

PVC SCH 40 P- OR

J-TRAP 3/4”2” (51MM)

TRAPS MUST BE DEEP ENOUGH TO OFFSET MAXIMUM STATIC DIFFERENCES — GENERALLY, TWO INCHES (51MM).

1LENNOX P-TRAP 49P66 REQUIRES A LARGER INSTALLATION SPACE THAN THE J-TRAP 91P90.

2PIPE NIPPLE PROVIDED IN BAG ASSEMBLY - SCH 80, 3/4” I. D. X 5” - 34K7401 (1): CUT THE PIPE IN HALF AND USE IT TO ROUTE THE MAIN DRAIN.

TRAP DEPTH

TO APPROVED

 

 

DRAIN

 

FOR NEGATIVE PRESSURE COILS (BLOWER

DRAIN LINE SHOULD

AFTER COIL) TRAPS ARE REQUIRED ON ALL

SLOPE A MINIMUM OF

DRAIN LINES CONNECTED TO COIL.

ONE

INCH

PER

10

 

 

FEET

(25MM

PER

3

 

METERS)

 

 

Figure 9. Typical Main and Overflow Drain

Page 6

Image 6
Contents Table of Contents Shipping and Packing ListGeneral CBX25UH Unit Dimensions inches mm AIR FlowInstallation Clearances RequirementsUpflow Application InstallationRefrigerant Metering Device Horizontal ApplicationsRIGHT-HAND AIR Discharge Remove two screws securing the blow-off preventionCondensate Drain Overflow Drain LineSloping the Drain Install Condensate DrainDuct System and Filters Test Condensate DrainConnecting Refrigerant Lines Installing Duct SystemSealing the Unit Electrical Connections Volt ConversionAirflow Cooling Blower Speed Change Blower SpeedChanging Blower Speed Check-out Procedures OperationCabinet Insulation MaintenanceRepairing Damaged Insulation Emergency Heat Heating Heat PumpStart-Up and Performance Checklist Upflow Configuration Start-Up and Performance Checklist Horizontal Configuration

Merit CBX25UH Series, Lennox Air Handler specifications

Lennox International Inc is a leading provider of innovative HVAC systems, and among its standout products is the Merit CBX25UH Series, an advanced air handler designed to enhance indoor comfort while ensuring energy efficiency. This series is specifically designed for use with the Lennox cooling and heating systems, making it an ideal choice for homeowners seeking versatile climate control solutions.

One of the primary features of the Merit CBX25UH Series is its multi-position installation capability, allowing it to be configured for upflow, downflow, or horizontal airflow. This flexibility makes it suitable for a wide range of home layouts and needs. The series is designed for use with a variety of Lennox outdoor units, ensuring seamless integration into existing HVAC systems.

The air handler is equipped with a high-efficiency blower motor that optimizes airflow, enhancing indoor comfort while minimizing energy consumption. This variable-speed blower motor not only operates quietly but also adjusts airflow based on the specific heating or cooling demands of the home. This feature significantly improves energy efficiency, helping homeowners save on utility bills while reducing their environmental impact.

Another key technology in the Merit CBX25UH Series is its SmartLynx™ communicating technology, which allows for efficient communication between the air handler and other HVAC components. This advanced communication ensures that the system operates at peak performance, providing consistent and reliable heating and cooling throughout the space.

The CBX25UH also boasts a durable cabinet that offers excellent insulation, minimizing energy loss and enhancing overall system efficiency. The cabinet's design reduces noise levels, contributing to a more peaceful indoor environment. Additionally, the air handler features a robust filtration system that helps maintain indoor air quality by capturing dust and allergens, ensuring a healthier living space.

Lastly, the Merit CBX25UH Series is backed by Lennox’s renowned reliability and quality. Homeowners can have peace of mind knowing they are investing in a product designed to deliver dependable performance for years to come. Overall, the Merit CBX25UH Series is a top choice for those seeking a powerful, efficient, and flexible air handling solution within their HVAC system.