6. POWER UNIT INSTALLATION
6.1 LOCATING THE POWER UNIT
•Locate the power unit away from the general living area in an accessible location for cleaning and maintenance.
•Locate the power unit within 6 feet of a grounded electrical outlet. The power unit requires a 120 VAC power source.
•Do not locate the power unit close to a source of extreme heat (i.e.: water
heater) or in an area with a high ambient temperature (i.e.: attic, furnace room).
•Do not locate the power unit where the temperature can drop below 0°C (32°F).
•If the power unit is located in a closet or a small utility room, make sure the area is
NOTE: Refer to NuTone website for information on tubing installation | |||
(www.nutone.com). |
|
| |
6.2 MOUNTING POWER UNIT |
|
| |
CAUTION | MINIMUM WALL CLEARANCE | ||
Make sure to assemble the wall mounting | DIMENSIONS |
| |
|
| ||
bracket with the screws directly onto a | 14" MIN. | ||
wall stud for a solid installation. | |||
PVC TUBING STRAP |
| ||
|
| ||
1. Carefully remove debris pail from power | INLET | INLET | |
unit. Make sure bag is properly installed in |
| EXHAUST | |
power unit. Remove accessories and | TOP VIEW |
| |
installation kit. Securely reinstall pail. |
|
| |
2. Install the |
|
| |
power unit and press firmly (do not glue). |
|
| |
Remove the plastic cap from the inlet | CEILING |
| |
opening only if your installation requires the | 12" MINIMUM TO CEILING |
| |
connection into both inlets. |
| ||
WALL BRACKET | |||
| |||
| EXHAUST | ||
|
| ||
DO NOT GLUE |
|
| |
|
| 12" | |
REMOVE | INLET | INLET | |
PLASTIC CAP | |||
(IF NEED BE) | 30" |
| |
| 50" |
| |
AO0034 |
|
| |
3. Install mounting bracket on a wall stud within | FRONT VIEW |
| |
6 feet of a grounded electrical outlet, at the |
|
| |
distances specified on illustration beside. | 18" MINIMUM ABOVE FLOOR | ||
Ensure that wall between mounting bracket |
|
| |
and inlet is straight and leveled. |
|
| |
| FLOOR |
| |
| AD0043A |
| |
- 6 - |
|
|