7. GROUNDING INSTRUCTIONS

!WARNING

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance — if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current, to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

This appliance is for use on a nominal 120-volt circuit and has a grounding attachment plug that looks like the plug illustrated below. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adapter should be used with this appliance.

1.Using pliers, install both crimp connectors (included) to low voltage wire (18 gauge minimum, 2-conductor, model 376, not included).

2.Connect low voltage wire to tabs located on outside of the power unit.

3.The power unit is equipped with a 6-foot grounded cord. Plug cord into 120-volt grounded receptacle.

 

 

CRIMP CONNECTORS

 

POWER UNIT

LOW VOLTAGE TABS

 

 

POWER

OVERCURRENT

PROTECTOR BUTTON

 

CORD

 

GROUNDED

 

 

 

 

OUTLET BOX

INLET

 

GROUNDED

LEADS

 

 

OUTLETS

 

 

MODEL 376 (18/2)

 

GROUNDING PIN

 

 

LOW VOLTAGE WIRE

 

 

 

 

TO

 

 

OTHER

 

 

INLETS

AE0032

 

 

INLET

INLET

INLET

NOTE: INLET LEADS TO BE CONNECTED TO POWER UNIT LOW VOLTAGE TABS USING CRIMP CONNECTORS (INCLUDED) AND LOW VOLTAGE HARNESS.

- 8 -

Image 8
Contents Central Vacuum Power Unit Model NO. SFDB-DCImportant Safety Instruc Operation Detailed ViewWhen to Change BAG BAG ReplacementRemoving Filter Reinstalling FilterSecondary Filter Mounting Power Unit Power Unit InstallationLocating the Power Unit Power Unit Installation CONT’D Grounding Instructions Troubleshooting Guide Removed CenterProduct specifications subject to change without notice Aspiradora Central Modelo N. SFDB-DCAdvertencia Funcionamiento Ilustración DetalladaMomento DE Cambiar EL Saco Sustitución DEL SacoPara Volver a Instalar EL Filtro Filtro SecundarioPara Retirar EL Filtro Montaje DE LA Unidad DE Potencia Instalación DE LA Unidad DE PotenciaUbicación DE LA Unidad DE Potencia Instalación DE LA Unidad DE Potencia continuación Instrucciones Para LA Conexión a Tierra AdvertanciaGuía Para LA Solución DE Problemas Problema Causas Posibles Soluciones PosiblesGarantía Limitada DE UN AÑO