Maytag LMDV-40 SERIES Lighting Instructions Electronic, What to do if YOU Smell GAS, To Shut OFF

Page 18

LIGHTING INSTRUCTIONS — ELECTRONIC

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A. When lighting the appliance, follow these instructions exactly.

B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If your gas supplier cannot be reached, call the fire department.

C.Use only your hand to turn the gas control lever. Never use tools. If the lever will not turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this Page.

2.Turn remote wall switch to “OFF.”

3.Open lower control compartment door.

4.Verify main line shut-off valve is open.

Honeywell Electronic Gas Control Valve

ON / OFF Switch

CONTROL

OFF ON

N

 

 

I

IGNITER

 

 

 

 

ISP

Front View

5.Turn the OFF/ON switch to “OFF”. Do not force.

6.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this Page. If you do not smell gas, go to the next step.

7.Turn the OFF/ON switch to “ON”. Do not force.

8.Turn “ON” all electrical power to appliance (remote wall or appliance switch).

9.Close lower control compartment door.

TO SHUT OFF

1.Turn off all electrical power to the appliance (remote wall switch).

18

TO TURN OFF GAS TO APPLIANCE

1.

For complete shut-down, turn remote wall switch to

3. Turn the OFF/ON switch to “OFF”. Do not force.

 

“OFF.”

4.

Close the main line shut-off valve.

2.

Open lower control compartment door.

5.

Close lower control compartment door.

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Image 18
Contents LMDV-3530 Model Shown Retain These Instructions For Future Reference875,028M REV. C 06/2005 Listing Agency OTL Report No -F-31-5Table of Contents CongratulationsInlet Gas Supply Pressure All models Fuel # Minimum Maximum Gas PressureBurn-in Period SeriesOperation and Care of Your Appliance Reinstalling Control Compartment DoorOFF/ON switch Control ValveMaintenance See Maintenance Schedule,SIT Millivolt Gas Valve Front Glass Enclosure Panel, Removal and Installation Removing Glass Enclosure Panels Remove the top louver assembly by pulling it up and outInstalling Glass Enclosure Panels See FigureGlowing Embers Placement of Glowing EmbersLMDV-4035 Install as Follows ReferenceLOG SET Catalog Number H3366Model LMDV-4035 Catalog Number H3365Flame Appearance and sooting Burner AdjustmentsAir Shutter Adjustment Guidelines Qualified Technicians onlyEnsurefrontglasspanelisinplace and sealed during adjustment Electronic Pilot AssemblyWarranty Replacement Parts Wiring DiagramsMillivolt Wiring Diagram Your Fireplaces Model NumberAccessory Components Product Reference InformationWall Thermostat Accessory Components Polished Brass & Brushed Stainless Louvers Kits Polished Brass Piece Trim KitScreen Heat Guard Kit Polished Brass & Brushed Stainless 2-Piece Door Frame KitsTo Turn OFF GAS to Appliance What to do if YOU Smell GASTo on Lighting Instructions Lighting Instructions ElectronicWhat to do if YOU Smell GAS To Shut OFFMaintenance Schedule Maintenance Task Accomplishing Person ProcedureWhile HOT Troubleshooting Symptom Possible Causes Corrective ActionTroubleshooting Procedure Electronic Ignition System Gas Controls Honeywell Millivolt Replacement Parts ListGas Controls SIT Millivolt Gas Controls Honeywell ElectronicReplacement Parts LMDV-4035 LMDVT-3328 & LMDVR-353024 P/N 875,028M REV. C 06/2005 West Taft Avenue Orange, CA

LMDV-35 SERIES, LMDV-33 SERIES, LMDV-40 SERIES specifications

The Maytag LMDV-33, LMDV-40, and LMDV-35 series of commercial laundry machines are designed for high-efficiency laundering in various contexts, from laundromats to on-premise laundry operations. These series are crafted with innovative technologies and features that maximize productivity while ensuring reliability, performance, and user satisfaction.

One of the standout features of these machines is their Energy Star certification, which highlights their energy-efficient design. By utilizing advanced washing technologies and optimized programs, they minimize water and electricity consumption without compromising on cleaning effectiveness. This makes them an environmentally conscious choice for businesses aiming to reduce their operational costs and carbon footprint.

The LMDV series offers a range of capacities, enabling operators to choose the machine that best fits their specific laundry demands. The LMDV-33 is designed for smaller loads, while the LMDV-40 and LMDV-35 cater to medium and larger capacities. This flexibility allows businesses to scale their operations effectively while ensuring that laundry is processed efficiently within a suitable time frame.

Built with durability in mind, these machines feature a robust construction that withstands the rigors of constant use. The stainless-steel tub and door are resistant to wear and tear, contributing to a longer lifespan. The advanced suspension system minimizes vibrations, allowing for quieter operation—a crucial advantage in commercial settings.

One of the technological highlights of the Maytag LMDV series is the intuitive control panel. With user-friendly digital displays and pre-set cycles, operators can easily select the appropriate settings for various fabric types and soil levels. This streamlines the laundry process and contributes to a higher level of operational efficiency.

Safety features, such as an automatic door lock during operation, are also integral to these machines. This ensures that operators can run their laundry without the worry of accidental interruptions. Additionally, the machines are designed with easy maintenance in mind, featuring accessible components that simplify routine servicing.

In summary, the Maytag LMDV-33, LMDV-40, and LMDV-35 series represent a commitment to excellence in commercial laundry solutions. With their energy efficiency, robust construction, intuitive controls, and safety features, these machines stand out as reliable investments for businesses looking to enhance their laundry operations. Adopting these advanced machines not only elevates laundry standards but also contributes to overall operational success.