Maytag LMDV-33 SERIES manual Wiring Diagrams, Millivolt Wiring Diagram, Warranty Replacement Parts

Page 13

WIRING DIAGRAMS

Electronic Wiring Diagram (Honeywell) Showing Blower Wiring for Optional FBK-100, FBK-200 & FBK-250 Kits

 

 

Wiring diagrams are provided here for refer-

 

 

 

 

 

 

 

 

 

 

Schematic Representation Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ence purposes only. This information is also

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall Mounted Blower Speed Control Switch or

provided on schematics attached directly to the

 

 

 

 

 

Auxiliary View A

 

 

 

 

 

ON/OFF Switch for Blower Kit (optional)

appliance on a pullout panel located within the

 

 

 

 

 

J-Box Wiring when

Relay Module C/W FBK-250 only. Plug blower

 

 

 

 

 

 

 

 

 

 

using unit mounted

 

 

 

 

 

control compartment.

 

 

 

 

 

relay module.

 

into J-Box receptacle for FBK-100 or FBK-200

 

 

 

 

 

 

 

 

 

 

 

application. View A for J-Box wiring.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet Box Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

120VAC

 

 

 

 

 

 

Ground Screw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120

BK

 

 

 

 

 

 

 

 

 

G

Optional Blower

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

VAC

 

W

 

 

Label all wires prior to discon-

Junction Box

 

 

 

 

 

 

*OFF/ON Switch

 

 

 

 

nection when servicing con-

 

 

 

 

 

Pilot Burner

(Integral with

 

 

G

BK

trols. Wiring errors can cause

Assembly

Gas Valve)

Break off Tab

 

R

 

 

 

 

improper and dangerous appli-

 

Honeywell

 

 

 

 

ance operation.

 

Hot side

Junction

 

White Wire

 

Electronic

 

 

of Outlet

Box

 

to Opposite

 

 

Gas

 

 

 

Side (neutral)

 

 

Valve

 

 

 

 

Millivolt Wiring Diagram

 

 

 

 

 

 

 

 

Igniter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Leave the OFF/ON switch, which is

 

 

 

 

 

 

 

 

Connector

 

 

 

 

 

 

 

 

 

 

 

GROUND

integral with the gas valve, in the ON

Schematic Representation Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transformer

 

 

position.

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** Optional Control Switches: Wall

If any of the original wire as supplied must

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch, Wall Thermostat or Remote

 

 

 

 

 

BK

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

Control Receiver.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

24 V

 

 

 

 

 

 

120 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be replaced, it must be replaced with Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

Secondary

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Primary

AWM 105o C - 18 gage wire.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. If any of the original wire as supplied

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

must be replaced, use Type AWM 105°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK = BLACK

BL = BLUE

- 18 gage wire ONLY.

 

 

 

 

 

Optional Control Switch

BK

 

 

 

 

2. 120 VAC, 60 Hz - Less than 3 Amps.

 

 

 

 

 

 

 

 

 

 

R = RED

W = WHITE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

Caution: label all wires prior to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G = GREEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

disconnection when servicing controls.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field Wired

 

 

TH TP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring errors can cause improper and

 

TP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dangerous operation.

 

 

 

 

 

Figure 17

 

 

 

 

 

 

 

 

 

Wired

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermopile

TH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARRANTY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPLACEMENT PARTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Optional Switch

 

 

Your gas appliance is covered by a limited twenty

 

 

 

A complete parts list is found at the end of

 

 

Field Wired

 

year warranty. You will find a copy of the war-

 

 

 

this manual. Use only parts supplied from the

 

 

 

ranty accompanying this manual. Please read

 

 

 

manufacturer.

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory

 

the warranty to be familiar with its coverage.

 

 

 

 

 

 

Normally, all parts should be ordered through

 

 

 

 

 

 

 

 

 

 

Wired

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Retain this manual. File it with your other docu-

 

 

 

your Lennox distributor or dealer. Parts will be

Standard OFF/ON Switch

 

 

 

 

 

shipped at prevailing prices at time of order.

 

 

ments for future reference.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*OptionalKitsInstalled-OFF/ONwallswitch,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When ordering repair parts, always give the

wall thermostat or remote control receiver.

 

PRODUCT REFERENCE INFORMATION

 

 

 

 

 

 

 

 

 

 

 

 

 

following information:

Note: Turn the appliance-mounted OFF/ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

We recommend that you record the following im-

 

 

 

1. The model number of the appliance.

burner control switch to the OFF position if

 

 

 

 

any of these kits are installed.

 

 

portant information about your fireplace. Please

 

 

 

2. The serial number of the appliance.

 

 

 

 

contact your Lennox dealer for any questions

 

 

 

3. The part number.

Figure 16

 

 

or concerns. For the number of your nearest

 

 

 

4. The description of the part.

 

 

 

 

Lennox dealer, please call 800-731-8101

 

 

 

 

 

 

5. The quantity required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. The installation date of the appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you encounter any problems or have any ques-

Your Fireplace's Model Number

 

 

________________________________________

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tions concerning the installation or application

Your Fireplace's Serial Number

 

 

________________________________________

 

 

 

 

 

 

 

of this system, please contact your distributor,

 

 

 

 

 

 

 

 

 

or Lennox directly:

The Date On Which Your Fireplace Was

Installed___________________________

 

 

 

 

 

 

LENNOX HEARTH PRODUCTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Type of Gas Your Fireplace Uses

____________________________________

 

 

 

 

 

 

 

1110 West Taft Avenue

 

 

 

 

 

 

 

Orange, CA 92865

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Your Dealer's Name ________________________________________________

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

 

 

 

 

 

 

 

 

 

Image 13
Contents 875,028M REV. C 06/2005 Retain These Instructions For Future ReferenceLMDV-3530 Model Shown Listing Agency OTL Report No -F-31-5Congratulations Table of ContentsBurn-in Period Gas PressureInlet Gas Supply Pressure All models Fuel # Minimum Maximum SeriesOFF/ON switch Reinstalling Control Compartment DoorOperation and Care of Your Appliance Control ValveSee Maintenance Schedule, MaintenanceSIT Millivolt Gas Valve Front Glass Enclosure Panel, Removal and Installation Installing Glass Enclosure Panels Remove the top louver assembly by pulling it up and outRemoving Glass Enclosure Panels See FigureLMDV-4035 Install as Follows Placement of Glowing EmbersGlowing Embers ReferenceCatalog Number H3366 LOG SETCatalog Number H3365 Model LMDV-4035Air Shutter Adjustment Guidelines Burner AdjustmentsFlame Appearance and sooting Qualified Technicians onlyElectronic Pilot Assembly Ensurefrontglasspanelisinplace and sealed during adjustmentMillivolt Wiring Diagram Wiring DiagramsWarranty Replacement Parts Your Fireplaces Model NumberProduct Reference Information Accessory ComponentsWall Thermostat Accessory Components Screen Heat Guard Kit Polished Brass Piece Trim KitPolished Brass & Brushed Stainless Louvers Kits Polished Brass & Brushed Stainless 2-Piece Door Frame KitsWhat to do if YOU Smell GAS To Turn OFF GAS to ApplianceTo on What to do if YOU Smell GAS Lighting Instructions ElectronicLighting Instructions To Shut OFFMaintenance Task Accomplishing Person Procedure Maintenance ScheduleWhile HOT Symptom Possible Causes Corrective Action TroubleshootingTroubleshooting Procedure Electronic Ignition System Gas Controls SIT Millivolt Replacement Parts ListGas Controls Honeywell Millivolt Gas Controls Honeywell ElectronicLMDV-4035 LMDVT-3328 & LMDVR-3530 Replacement PartsWest Taft Avenue Orange, CA 24 P/N 875,028M REV. C 06/2005

LMDV-35 SERIES, LMDV-33 SERIES, LMDV-40 SERIES specifications

The Maytag LMDV-33, LMDV-40, and LMDV-35 series of commercial laundry machines are designed for high-efficiency laundering in various contexts, from laundromats to on-premise laundry operations. These series are crafted with innovative technologies and features that maximize productivity while ensuring reliability, performance, and user satisfaction.

One of the standout features of these machines is their Energy Star certification, which highlights their energy-efficient design. By utilizing advanced washing technologies and optimized programs, they minimize water and electricity consumption without compromising on cleaning effectiveness. This makes them an environmentally conscious choice for businesses aiming to reduce their operational costs and carbon footprint.

The LMDV series offers a range of capacities, enabling operators to choose the machine that best fits their specific laundry demands. The LMDV-33 is designed for smaller loads, while the LMDV-40 and LMDV-35 cater to medium and larger capacities. This flexibility allows businesses to scale their operations effectively while ensuring that laundry is processed efficiently within a suitable time frame.

Built with durability in mind, these machines feature a robust construction that withstands the rigors of constant use. The stainless-steel tub and door are resistant to wear and tear, contributing to a longer lifespan. The advanced suspension system minimizes vibrations, allowing for quieter operation—a crucial advantage in commercial settings.

One of the technological highlights of the Maytag LMDV series is the intuitive control panel. With user-friendly digital displays and pre-set cycles, operators can easily select the appropriate settings for various fabric types and soil levels. This streamlines the laundry process and contributes to a higher level of operational efficiency.

Safety features, such as an automatic door lock during operation, are also integral to these machines. This ensures that operators can run their laundry without the worry of accidental interruptions. Additionally, the machines are designed with easy maintenance in mind, featuring accessible components that simplify routine servicing.

In summary, the Maytag LMDV-33, LMDV-40, and LMDV-35 series represent a commitment to excellence in commercial laundry solutions. With their energy efficiency, robust construction, intuitive controls, and safety features, these machines stand out as reliable investments for businesses looking to enhance their laundry operations. Adopting these advanced machines not only elevates laundry standards but also contributes to overall operational success.