INSTALL VERMICULITE, VOLCANIC STONE, GLOWING EMBERS AND LOGS

1.Remove the front glass enclosure panel (see Removing Glass Enclosure Panels on this page).

2.Carefully remove the old logs, embers volcanic stone and vermiculite from the firebox. Handle logs carefully to prevent breakage.

3.Install Vermiculite - Place some vermiculite on the firebox floor around the burner (the entire bag of vermiculite will NOT be used). See Figures 8 & 9. DO NOT PLACE ANY VERMICULITE ON THE BURNER. Mound up a portion of the vermiculite in front of the burner.

4.Install decorative volcanic stone - Sprinkle the decorative volcanic stone (dark colored) on top of the vermiculite (light colored) in a pleasing pattern (see Figures 8 & 9).

5.Placement of Glowing Embers -

Separate the Embers (rockwool) into pieces about the size of a quarter (see Figure 7). Keep the pieces fluffed up, not matted. Distribute these pieces over the surface of the burner, as shown in Figures 8 & 9. Do not use more than is necessary. Ensure that the main burner slots remain uncovered by the ember material.

Note: This appliance is provided with enough Glowing Embers for several applications, do not use all that is in a new bag at one time. For bestglowingeffect,replacetheembermaterial annually.

6.Placement of Logs and Twigs -

All logs that have locating notches or slots to help ensure that they are properly positioned. All top logs that rest on lower logs, do so over notches, indents or pins. Proper twig placement is critical to prevent sooting. Twigs shouldbeplacedinthegapsbetweentheflame peaks and should be positioned so they do not impinge the flames.

LMDV-3328 & LMDV-3530 - Install as Follows

Carefully position the ceramic fiber logs and twigs over the burner as shown in Figure 8. Logs should be placed in the order shown and per the following instructions.

1. Place the rear log (A) as shown. Position the 2 notches on the bottom of the log over the 2 corresponding locating brackets against the back wall of firebox.

2. Place the left log (B) as shown. The notch on the bottom of the log should fit over the corresponding locating bracket.

3. Place the right log (E) as shown. The hole on the back of the log should fit over the corresponding pin on the rear log (A). Make sure that the log is positioned so it aligns to the sides of the gas ports on the corner of the burner.

4. Place the left center log (C) as shown. The forked end of the log fits into the cor- responding notch on rear log (A). The slot on the other end (bottom) of log fits over the corresponding locating bracket on the sub-floor.

5. Place the right center log (D) as shown. One end of the log fits into the corresponding indent on the right log (E). The slot on the other end (bottom) of log fits over the corresponding locating bracket on the sub- floor.

LMDV-4035 - Install as Follows

Carefully position the ceramic fiber logs and twigs over the burner as shown in Figure 9. Logs should be placed in the order shown and per the following instructions.

1.Position the center log (C) onto the 2 cor- responding location pins on the burner.

2. Place the rear log (A) as shown. Position the 2 notches on the bottom of the log over the 2 corresponding locating brackets against the back wall of firebox.

3. Place the left log (B) as shown. The notch on the bottom of the log should fit over the corresponding locating bracket.

4. Place the right log (E) as shown. The notch on the bottom of the log should fit over the corresponding locating bracket. Make sure that the log is positioned so it aligns to the sides of the gas ports on the corner of the burner.

5. Place the center front log (D) as shown. The slot in the bottom of the log fits over the corresponding location bracket on the sub-floor.

WARNING

DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

WARNING

The size and position of the log set was engineered to give the appliance a safe, reliable and attractive flame pattern. Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion, soot- ing, and poor flame quality.

WARNING

This appliance is not designed to burn wood. Any attempt to do so could cause irreparable damage to appliance and prove hazardous to your safety.

WARNING

If logs are not installed according totheloginstallationinstructions, flameimpingementandimproper combustioncouldoccurandresult in soot and/or excessive produc- tion of carbon monoxide (CO), a colorless, odorless, toxic gas.

Glowing Embers

Separate into Quarter

Size (separate) Pieces

Bag of Glowing

Embers (rockwool)

Figure 7

REFERENCE

Firebox Accessories / Parts

Cat. No.

Model No.

Description

 

 

 

88L53

FGE

Bag of Glowing Embers

 

 

(1 oz. rockwool)

 

 

 

42363

 

Vermiculite, Bag (2 liters)

 

 

 

80L42

FDVS

Bag of Decorative

Volcanic Stone

 

 

 

 

 

Table 8

Image 8
Contents Retain These Instructions For Future Reference 875,028M REV. C 06/2005LMDV-3530 Model Shown Listing Agency OTL Report No -F-31-5Table of Contents CongratulationsGas Pressure Burn-in PeriodInlet Gas Supply Pressure All models Fuel # Minimum Maximum SeriesReinstalling Control Compartment Door OFF/ON switchOperation and Care of Your Appliance Control ValveSIT Millivolt Gas Valve MaintenanceSee Maintenance Schedule, Front Glass Enclosure Panel, Removal and Installation Remove the top louver assembly by pulling it up and out Installing Glass Enclosure PanelsRemoving Glass Enclosure Panels See FigurePlacement of Glowing Embers LMDV-4035 Install as FollowsGlowing Embers ReferenceLOG SET Catalog Number H3366Model LMDV-4035 Catalog Number H3365Burner Adjustments Air Shutter Adjustment GuidelinesFlame Appearance and sooting Qualified Technicians onlyEnsurefrontglasspanelisinplace and sealed during adjustment Electronic Pilot AssemblyWiring Diagrams Millivolt Wiring DiagramWarranty Replacement Parts Your Fireplaces Model NumberWall Thermostat Accessory ComponentsProduct Reference Information Accessory Components Polished Brass Piece Trim Kit Screen Heat Guard KitPolished Brass & Brushed Stainless Louvers Kits Polished Brass & Brushed Stainless 2-Piece Door Frame KitsTo on To Turn OFF GAS to ApplianceWhat to do if YOU Smell GAS Lighting Instructions Electronic What to do if YOU Smell GASLighting Instructions To Shut OFFWhile HOT Maintenance ScheduleMaintenance Task Accomplishing Person Procedure Troubleshooting Symptom Possible Causes Corrective ActionTroubleshooting Procedure Electronic Ignition System Replacement Parts List Gas Controls SIT MillivoltGas Controls Honeywell Millivolt Gas Controls Honeywell ElectronicReplacement Parts LMDV-4035 LMDVT-3328 & LMDVR-353024 P/N 875,028M REV. C 06/2005 West Taft Avenue Orange, CA

LMDV-35 SERIES, LMDV-33 SERIES, LMDV-40 SERIES specifications

The Maytag LMDV-33, LMDV-40, and LMDV-35 series of commercial laundry machines are designed for high-efficiency laundering in various contexts, from laundromats to on-premise laundry operations. These series are crafted with innovative technologies and features that maximize productivity while ensuring reliability, performance, and user satisfaction.

One of the standout features of these machines is their Energy Star certification, which highlights their energy-efficient design. By utilizing advanced washing technologies and optimized programs, they minimize water and electricity consumption without compromising on cleaning effectiveness. This makes them an environmentally conscious choice for businesses aiming to reduce their operational costs and carbon footprint.

The LMDV series offers a range of capacities, enabling operators to choose the machine that best fits their specific laundry demands. The LMDV-33 is designed for smaller loads, while the LMDV-40 and LMDV-35 cater to medium and larger capacities. This flexibility allows businesses to scale their operations effectively while ensuring that laundry is processed efficiently within a suitable time frame.

Built with durability in mind, these machines feature a robust construction that withstands the rigors of constant use. The stainless-steel tub and door are resistant to wear and tear, contributing to a longer lifespan. The advanced suspension system minimizes vibrations, allowing for quieter operation—a crucial advantage in commercial settings.

One of the technological highlights of the Maytag LMDV series is the intuitive control panel. With user-friendly digital displays and pre-set cycles, operators can easily select the appropriate settings for various fabric types and soil levels. This streamlines the laundry process and contributes to a higher level of operational efficiency.

Safety features, such as an automatic door lock during operation, are also integral to these machines. This ensures that operators can run their laundry without the worry of accidental interruptions. Additionally, the machines are designed with easy maintenance in mind, featuring accessible components that simplify routine servicing.

In summary, the Maytag LMDV-33, LMDV-40, and LMDV-35 series represent a commitment to excellence in commercial laundry solutions. With their energy efficiency, robust construction, intuitive controls, and safety features, these machines stand out as reliable investments for businesses looking to enhance their laundry operations. Adopting these advanced machines not only elevates laundry standards but also contributes to overall operational success.