Raypak 503 thru 2003, 504 thru 2004 manual TempTracker Mod, Or PID logic

Page 7

Cat. I*

84%

TempTracker Mod

Raypak’s MVB comes standard with TempTracker Mod. This control can be used for space heating and hot water supply with six application-specific modes to meet various applica- tions, including outdoor reset for heating systems. The control monitors and displays inlet and outlet temperatures on all applications as well as monitor outdoor temperature when an outdoor reset mode is selected. Only Raypak’s TempTracker Mod allows for a user definable outdoor reset slope. Boiler adjustable limits prevent over cycling, saving energy and extending the life of the boiler. Your MVB is never down with a sensor failure thanks to Raypak’s exclusive TempTracker software. It can operate with as little as one function- ing sensor, keeping you up and running until service arrives.

• P or PID logic

0-10VDC Setpoint/Direct Drive Input

4-20ma output

-Standard on MVB Cat. I

• Building management direct control

-Coming soon on MVB Cat. IV

• LCD Display

 

MVB

 

 

 

 

 

 

Recovery Rates (GPH)

 

 

 

 

 

 

Input

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

 

500

5,091

2,545

1,697

1,273

1,018

848

727

636

566

509

463

424

392

364

339

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

750

7,636

3,818

2,545

1,909

1,527

1,273

1,091

955

848

764

694

636

587

545

509

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1100

11,200

5,600

3,733

2,800

2,240

1,867

1,600

1,400

1,244

1,120

1,018

933

862

800

747

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500

15,273

7,636

5,091

3,818

3,055

2,545

2,182

1,909

1,697

1,527

1,388

1,273

1,175

1,091

1018

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1999

20,353

10,177

6,784

5,088

4,071

3,392

2,908

2,544

2,261

2,035

1,850

1,850

1,566

1,454

1,357

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cat. I*

84%

85%

Cat. IV

87%

MVB

 

 

 

 

 

 

Recovery Rates (GPH)

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

 

500

5,091

2,545

1,697

1,273

1,018

848

727

636

566

509

463

424

392

364

339

750

7,636

3,818

2,545

1,909

1,527

1,273

1,091

955

848

764

694

636

587

545

509

1045

10,640

5,320

3,547

2,660

2,128

1,773

1,520

1,330

1,182

1,064

967

887

818

760

709

1425

14,682

7,341

4,894

3,670

2,936

2,447

2,097

1,835

1,631

1,468

1,335

1,223

1,129

1,049

979

1900

19,576

9,788

6,525

4,894

3,915

3,263

2,797

2,447

2,175

1,958

1,780

1,631

1,506

1,398

1,305

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MVB

 

 

 

 

 

 

Recovery Rates (GPH)

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

 

500

5,273

2,636

1,758

1,318

1,055

879

753

659

586

527

479

439

406

377

352

750

7,909

3,955

2,636

1,977

1,582

1,318

1,130

989

879

791

719

659

608

565

527

999

10,535

5,267

3,512

2,634

2,107

1,756

1,505

1,317

1,171

1,053

958

878

810

752

702

1250

13,182

6,591

4,394

3,295

2,636

2,197

1,883

1,648

1,465

1,318

1,198

1,098

1,014

942

879

1500

15,818

7,909

5,273

3,955

3,164

2,636

2,260

1,977

1,758

1,582

1,438

1,318

1,217

1,130

1,055

1750

18,455

9,227

6,152

4,614

3,691

3,076

2,636

2,307

2,051

1,845

1,678

1,538

1,420

1,318

1,230

1999

21,080

10,540

7,027

5,270

4,216

3,513

3,011

2,635

2,342

2,108

1,916

1,757

1,622

1,506

1,405

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Image 7
Contents Models 504 thru Flexibility Key FeaturesRaypak’s Next Generation Modulating Boiler True ModulationSee Cat. #5100.22 Cold Water SolutionsMulti Boiler Solutions State of the art European combustion technologyWater Heaters Smallest Installed FootprintModel Amps Heater From Combustible For Service SideSoft HardGPM Simple ServiceabilityIgnition control Service diagnostic panel Burner on/off Pump on/off LED status panelOr PID logic TempTracker ModCold Water Run On/Off SwitchBoilers Status Display Lights

503 thru 2003, 504 thru 2004 specifications

Raypak, a well-known manufacturer in the HVAC and pool heating industry, has been at the forefront of innovation with their models 503 through 2003 and 504 through 2004. These models are recognized for their dependability, efficiency, and advanced features that cater to both residential and commercial applications.

One of the primary characteristics of the Raypak models 503 and 504 is their robust construction. Built with durability in mind, these heaters use high-quality materials that withstand varying weather conditions, ensuring longevity and reduced maintenance costs. The exterior casing is designed to resist corrosion, a common issue in humid environments, thereby enhancing the unit's lifespan.

Energy efficiency is another standout feature of the Raypak 503 and 504 models. These units integrate advanced heating technologies that utilize less energy while providing ample heating power. The proprietary heat exchanger design maximizes thermal transfer, ensuring that more of the energy consumed is effectively used for heating purposes. This not only contributes to lower utility bills but also aligns with growing environmental concerns regarding energy consumption.

In terms of technology, the Raypak models incorporate user-friendly digital controls that simplify the operation of the heater. These controls allow users to set precise temperatures and monitor system performance easily. Additionally, the built-in diagnostics feature alerts users to any issues, facilitating prompt maintenance and reducing downtime.

The compact design of these models is another benefit that does not go unnoticed. They can be installed in tight spaces, making them ideal for residential properties with limited room for large heating units. This flexibility in installation allows homeowners and contractors to optimize available space without sacrificing heating performance.

Moreover, both the 503 and 504 models come with a range of safety features. These include automatic water temperature limit controls and built-in freeze protection, which are essential for preventing damage during cold weather.

In summary, Raypak's 503 from 2003 and 504 from 2004 models showcase a blend of durability, energy efficiency, advanced technologies, and user-friendly features. They represent a commitment to providing high-quality heating solutions that meet the demands of modern consumers and businesses alike. With a focus on reliability and performance, Raypak continues to set benchmarks in the heating industry.