State of the art European combustion technology

11

1. Control Panel

Fully enclosed controls and wiring protect against damage or vandalism. Cabinet design affords easy access to controls for installation and service.

2. Temp-Tracker Mod Control

This factory-mounted multi-function control delivers precise load-tracking with selectable mode displays that are easy to access and read.

3.Universal Diagnostics Board

12LEDs monitor up to 22 safety circuits and store up to 256 fault codes.

4.Weather-Proof Jacket

Heavy gauge galvanized steel with

a UV-resistant Polytuf powder coat finish is impervious to weather and corrosion.

5. Combustion Air Fan

Cast aluminum, non-sparking construction.

6. Vent Pressure Switch

Monitors vent pressure and provides safe shut down if back pressure is excessive.

7. Minimum Clearance Requirements

Only one inch of side clearance is required from combustible surfaces.

8. Vertical Heat Exchanger

Cylindrical, multi-pass heat exchanger captures all radiant energy, eliminating the need for heavy refractory.

9. Rugged All-Bronze Headers

The proven choice for all applications.

10. Tube Sheet Construction

Eliminates the repair & maintenance problems associated with rolled-tube construction. Easy, cost-effective component replacement.

11. Viewing Port

Allows easy burner inspection.

Optional Equipment

Cold Water Solutions

Cold Water Start – For applications that require reliable protection against harmful con- densation caused by frequent, extended, cold water start-ups. Raypak’s Cold Water Start pro- tection system utilizes a proportional three- way valve to bypass water from the boiler out- let to the inlet during start-up, when the sys-

tem return water temperature is below the minimum acceptable level. (See Cat. #1000.19)

Cold Water Run – For applications requir- ing constant condensation protection. Raypak’s Cold Water Run system utilizes a variable- speed pump to inject just the right amount of water from the main system loop into the boil- er to maintain the optimum inlet temperature. This approach allows the full capacity of the boiler to be utilized to meet the system load,

while at the same time continuously maintaining the optimum inlet water temperature to prevent condensation. (See Cat. #1000.19)

Multi Boiler Solutions

Y-200 Boiler Sequencer – Provides addi- tional functionality for multiple-boiler installa- tions. Controls up to 8 MVB boilers with full PID logic. LonMark certified interface ensures seamless compatibility with LonWorks Building Management Systems (BMS)

(See Cat. #5100.22)

TempTracker Mod+ – Controls up to 16 Raypak MVBs with P or PID logic. Automatic or manually selectable lead-lag boiler operation. TempTracker Mod+ monitors and displays sup- ply water temperatures on all applications including outdoor temperature when outdoor reset mode is selected. (See Cat. # 5100.22)

3

Image 3
Contents Models 504 thru Flexibility Key FeaturesRaypak’s Next Generation Modulating Boiler True ModulationSee Cat. #5100.22 Cold Water SolutionsMulti Boiler Solutions State of the art European combustion technologyWater Heaters Smallest Installed FootprintModel Amps Heater From Combustible For Service SideSoft HardGPM Simple ServiceabilityIgnition control Service diagnostic panel Burner on/off Pump on/off LED status panelOr PID logic TempTracker ModCold Water Run On/Off SwitchBoilers Status Display Lights

503 thru 2003, 504 thru 2004 specifications

Raypak, a well-known manufacturer in the HVAC and pool heating industry, has been at the forefront of innovation with their models 503 through 2003 and 504 through 2004. These models are recognized for their dependability, efficiency, and advanced features that cater to both residential and commercial applications.

One of the primary characteristics of the Raypak models 503 and 504 is their robust construction. Built with durability in mind, these heaters use high-quality materials that withstand varying weather conditions, ensuring longevity and reduced maintenance costs. The exterior casing is designed to resist corrosion, a common issue in humid environments, thereby enhancing the unit's lifespan.

Energy efficiency is another standout feature of the Raypak 503 and 504 models. These units integrate advanced heating technologies that utilize less energy while providing ample heating power. The proprietary heat exchanger design maximizes thermal transfer, ensuring that more of the energy consumed is effectively used for heating purposes. This not only contributes to lower utility bills but also aligns with growing environmental concerns regarding energy consumption.

In terms of technology, the Raypak models incorporate user-friendly digital controls that simplify the operation of the heater. These controls allow users to set precise temperatures and monitor system performance easily. Additionally, the built-in diagnostics feature alerts users to any issues, facilitating prompt maintenance and reducing downtime.

The compact design of these models is another benefit that does not go unnoticed. They can be installed in tight spaces, making them ideal for residential properties with limited room for large heating units. This flexibility in installation allows homeowners and contractors to optimize available space without sacrificing heating performance.

Moreover, both the 503 and 504 models come with a range of safety features. These include automatic water temperature limit controls and built-in freeze protection, which are essential for preventing damage during cold weather.

In summary, Raypak's 503 from 2003 and 504 from 2004 models showcase a blend of durability, energy efficiency, advanced technologies, and user-friendly features. They represent a commitment to providing high-quality heating solutions that meet the demands of modern consumers and businesses alike. With a focus on reliability and performance, Raypak continues to set benchmarks in the heating industry.