Troubleshooting
Problem |
|
Motor will not start | SOLUTION: A,B |
Low/Surging pressure or no water flow | SOLUTION: C,D,E,F,G,H |
No chemical injection | SOLUTION: I,J,K,L |
Cause | Solution |
A- Tripped GFCI cord | Reset GFCI cord |
B- Tripped motor relay | Reset motor |
C- Insufficient water supply | See water supply section of this manual |
D- Plugged pump inlet filter | See maintenance section of this manual |
E- Wrong nozzle | Make sure high pressure nozzle is being used |
F- Plugged nozzle | Remove nozzle, check for blockage |
G- Worn nozzle | Replace nozzle |
H- Leak in pressure hose | Replace pressure hose |
I- Wrong nozzle | Make sure chemical nozzle is being used |
J- Back pressure from extra long discharge hose | Try shorter hose |
K- Leak in chemical siphon hose | Replace hose – use hose clamps if necessary |
L- Chemical strainer not submerged | Make sure strainer is completely submerged |
The manufacturer reserves the right to make improvements in design and/or changes in specifications at any time without incurring any obligation to install them on units previously sold.
Any Questions, Comments, Problems or Parts Orders
Call NorthStar Customer Service
19