Pump Oil Change

Comet BXD 1617E PumpCat 3DX25GSI Pump Maintenance and Storage

Pump Oil Change

1.) Place a suitable container below the pump to catch the used oil, then remove the oil fill cap and oil drain plug.

2.) Allow the used oil to drain completely, then reinstall the drain plug and tighten securely.

3.) Please dispose of used oil in a manner that is compatible with the environment. We suggest you take used oil in a sealed container to your local recycling center or service station for reclamation. Do not throw it in the trash, pour it on the ground or down the drain.

4.) With the pump in a level position, fill to the halfway point on the oil sight glass (see pump oil capacities below). For Comet pumps use Universal Tractor Transmission Oil or Mobil 1 15W50 synthetic oil. For Cat pumps use SAE30 non-detergent oil or Cat Pump Oil Item# 22158.

Comet BXD 1617E Pump

Cat 3DX25GSI Pump

Cat 2DX20ES Pump

fill cap

fill cap

fill cap

 

 

sight glass

sight glass

sight glass

drain plug

 

drain plug

drain plug

Oil capacity: 4.3oz. (.13L)

Oil capacity: 8.5 oz. (.25L)

Oil capacity: 8.5 oz. (.25L)

 

 