TROUBLESHOOTING

BSP5500L Generator

TROUBLESHOOTING

Problem

Cause

Solution

 

1.

Circuit breaker is open.

1.

Reset circuit breaker.

Engine is running, but

2.

Poor connection or defective cord set.

2.

Check and repair.

3.

Connected device is bad.

3.

Connect another device that is in good

no AC output is

 

 

 

condition.

available.

 

 

 

4.

Fault in generator.

4.

Contact Briggs and Stratton service

 

 

 

 

 

facility.

 

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

 

2.

Generator is overloaded.

2.

See “Don’t Overload the Generator” on

Engine runs good but

 

 

 

page 8.

bogs down when

3.

Engine speed is too slow.

3.

Contact Briggs and Stratton service

loads are connected.

 

 

 

facility.

 

4.

Shorted generator circuit.

4.

Contact Briggs and Stratton service

 

 

 

 

facility.

 

1.

Rocker switch set to “Off”.

1.

Set switch to “On”.

 

2.

Fuel valve is in the “Closed” position.

2.

Turn fuel valve to the “Open” position.

 

3.

Low oil level.

3.

Fill crankcase to proper level.

 

4.

Dirty air cleaner.

4.

Clean or replace air cleaner.

 

5.

Out of gasoline.

5.

Fill fuel tank.

 

6.

Stale gasoline.

6.

Drain gas tank and fill with fresh fuel.

Engine will not start;

7.

Spark plug wire not connected to

7.

Connect wire to spark plug.

 

spark plug.

 

 

or starts and runs

8.

Bad spark plug.

8.

Replace spark plug.

rough.

9.

Water in gasoline.

9.

Drain gas tank; fill with fresh fuel.

 

10.

Overchoking.

10.

Set choke to “Off” position.

 

11.

Excessively rich fuel mixture.

11.

Contact Briggs and Stratton service

 

 

 

 

facility.

 

12.

Intake valve stuck open or closed.

12.

Contact Briggs and Stratton service

 

 

 

 

facility.

 

13.

Engine has lost compression.

13.

Contact Briggs and Stratton service

 

 

 

 

facility.

Engine shuts down

1.

Out of gasoline.

1.

Fill fuel tank.

2.

Fault in engine.

2.

Contact Briggs and Stratton service

during operation.

 

 

 

facility.

 

 

 

 

 

1.

Load is too high.

1.

See “Don’t Overload the Generator” on

Engine lacks power.

 

 

 

page 8.

 

2.

Dirty air filter.

2.

Replace air filter.

 

 

 

 

 

 

1.

Choke is opened too soon.

1.

Move choke to halfway position till engine

Engine “hunts” or

 

 

 

runs smoothly.

falters.

2.

Carburetor is running too rich or too

2.

Contact Briggs and Stratton service

 

 

lean.

 

facility.

11

Page 11
Image 11
Briggs & Stratton bsp5500l owner manual Troubleshooting, Problem, Cause, Solution, BSP5500L Generator