Raypak 1505, 2005 Xtreme Pumping, Cold Water Run System, 000,000 $26,243 $22,039 $20,712 $16,898

Page 6

Xtreme Pumping

 

25 meters X 25 meters X 1-1/2 meters deep

 

 

 

 

 

 

 

 

 

Annual Fuel Usage

 

BTUH

 

 

 

 

Efficiencies

 

 

 

 

 

 

 

 

 

68%

78%

82%

97%

2,000,000

$26,243

$22,039

$20,712

$16,898

 

Using one 2,000,000 BTUH Heater

 

 

 

 

 

 

 

 

 

50 meters X 25 meters X 2 meters deep

 

 

 

 

 

 

 

 

 

Annual Fuel Usage

 

 

 

 

 

 

 

BTUH

 

Efficiencies

 

 

 

 

 

 

 

 

 

68%

78%

82%

97%

4,000,000

$80,653

$66,424

$62,047

$49,756

Using two 2,000,000 BTUH Heater

The annual fuel usage is based on maintaining an indoor swimming pool at 80ºF for 6 months of the year and using a fuel cost of $1.00 per therm.

How to use the table below:

1.Select the desired temperature of the pool water.

2.Determine the mean (average) temperature of the month in which the pool will be used.

3.Subtract the mean temperature from the desired swimming temperature. The difference is the temperature rise.

4.Calculate the surface area of the pool in square feet.

5.Under the column headed by the temperature rise, determined in Step 3, find the number closest to, but not less than, the pool surface area from Step 4. The left-hand column will give you the correct model heater.

Sizing Formula

BTUH INPUT REQUIRED = (Pool Surface Area square feet) X (Temperature Rise) X (15) This formula is based upon a 1º to 1-1/4º F temperature rise per hour and an average 3-1/2 MPH wind velocity.

Where high-wind conditions exist, select one size larger than determined by the formula.

Rapid Heating

For 1-1/2ºF rise per hour: Increase BTUH input by 50%.

For 2ºF rise per hour: Increase BTUH input by 100%.

Always select a heater equal to or larger than the requirement. Over-sizing generally reduces fuel costs.

Cold Water Run System

The XTherm comes standard with a state-of- the-art Cold Water Run system factory mounted and plumbed. Raypak’s Cold Water Run system provides constant protection against condensation in the primary heat exchanger. The system utilizes a variable speed pump to inject just the right amount of water from the main system loop into the heater to maintain the optimum inlet temperature. This allows the full capacity of the heater to be utilized to meet the system load, while at the same time continuously maintaining the optimum inlet water temperature to prevent condensation in the primary heat exchanger. All of this keeps the condensate were it belongs, in the stainless steel secondary heat exchanger.

6

Image 6
Contents Page Xtreme Performance 97%thermal efficiencyVent Pressure Switch Low Voltage Wiring TerminalFlow Switch Combustion Air FanCan be installed indoor or outdoors Xtreme VersatilityXtremely Small Footprint For propane gas, all models are 1-1/4 NPT000,000 $26,243 $22,039 $20,712 $16,898 Xtreme PumpingCold Water Run System 000,000 $80,653 $66,424 $62,047 $49,756Diagnostic Information Simple ServiceabilityOn-Board Diagnostic Center Xtreme ControlGAS
Related manuals
Manual 12 pages 19.26 Kb

2005, 1505 specifications

Raypak is a prominent name in the heating industry, known for its innovative and efficient heating solutions for residential and commercial applications. The models 2005, 1005, and 1505 are notable offerings from Raypak, each designed to provide reliable performance, energy efficiency, and user-friendly operation.

The Raypak 2005 model stands out for its robust construction and high efficiency. It utilizes advanced technology to ensure consistent heating and reliability. With a high-capacity output, the 2005 is ideal for larger pools and spa applications, efficiently maintaining desired temperatures even during colder months. Its digital control system allows for precise temperature settings, enabling users to customize their heating needs effectively.

The 1005 model is an excellent choice for medium-sized pools and spas, offering a perfect balance of power and energy efficiency. One of its key features is the ability to operate quietly, making it suitable for residential areas where noise can be a concern. The 1005 employs a reliable gas burning system that maximizes fuel efficiency and provides fast heating. Its compact design also makes it easy to install, saving space while delivering exceptional performance.

The Raypak 1505 model is designed for versatility, catering to a wide range of heating requirements. One of its standout characteristics is its corrosion-resistant heat exchanger, which ensures long-lasting performance even in harsh environments. The 1505 also incorporates a user-friendly digital interface, allowing for easy operation and monitoring of temperature settings. It supports both natural gas and propane, providing flexibility to users based on their energy source preferences.

All three models—the 2005, 1005, and 1505—benefit from Raypak's commitment to energy efficiency. They are designed to meet stringent environmental standards while minimizing operational costs for the user. Additionally, their reliable safety features, such as pressure switches and safety valves, ensure safe operation across various conditions.

In summary, Raypak's 2005, 1005, and 1505 models exhibit a combination of efficiency, durability, and user-friendliness. With their advanced technologies and adaptable designs, these heaters are suitable for a wide array of heating applications, providing users with reliable solutions for their heating needs. Whether for residential or commercial use, Raypak's commitment to quality and innovation makes these models excellent choices for anyone seeking dependable heating solutions.