Multiquip Qp-2TE manual QP- 2TE Pump Components, Water

Page 15

QP- 2TE — PUMP COMPONENTS

Figure 2 shows a typical application using the QP- 2TE Trash pump. Please note that this pump is intended for the removal of clean water and water containing some debris and solids. Maximum size of solids should not exceed 1.0 inch (25 mm) in diameter. DO NOT set strainer on bottom of water bed. Placing the strainer above the water bed will prevent the pump from drawing in excessive amounts of sand and foreign debris.

Figure 2. QP- 2TE Pump Application

1.

Pump – The model QP- 2TE is a 2-inch trash pump used

 

in general dewatering applications. Typical dewatering

 

applications consist of manholes, septic tanks, fast and

 

slow seepage ditch water, silt water, mud water and muck

 

water.

2.

Fill Cap – Prior to operation, the pump casing should be

 

filled with water.Remove this cap to add water to the pump.

 

After the initial prime, a sufficient amount of water will be

 

retained in the casing so that the operator will not need to

 

re-prime later.

 

If the casing is dry or has insufficient water, the pump will

 

have difficulty in priming which could lead to premature

 

mechanical seal wear thus causing damage to the pump.

3.

Discharge Port – Connect a 2-inch discharge hose to this

 

port.

4.

Worm Clamp – Used to secure the hose to the inlet and

 

outlet ports on the pump. Use two clamps to secure the

 

hose on the inlet side of the pump.

5.

Discharge Hose – Connect this flexible rubber hose to

 

the discharge port on the pump. Make sure that the hose

lays flat and is not kinked. Use only recommended type discharge hose. Contact Multiquip Parts Department for ordering information.

6. Suction Port – Connect a 2-inch inlet hose to this port. Use two worm clamps to secure the hose.

7. Suction Hose – Connect this flexible rubber hose to the suction portion the pump. Make sure that the hose lays flat and is not kinked. Use only recommended type suction hose. Contact Multiquip Parts Department for ordering information.

8. Clean-out Cover Handles To gain access to the pump's clean-out area, grip both handles, then pull to remove cover. Make sure both locking knobs have been released before attempting to remove clean-out cover.

9. Drain Plug – Remove this plug to drain water from the pump.

10. Clean-out Cover – Remove cover to gain access to the clean-out area.

11. Locking Knobs – Turn both knobs clockwise to secure clean-out cover, turn counterclockwise to release cover.

12. Strainer – Always attach a strainer to the bottom side of the suction hose to prevent large objects and debris from entering the pump. Strainer should be positioned so that it will remain completely under water.Running the pump with the strainer above water for long periods can damage pump.

QP- 2TE TRASH PUMP — OPERATION AND PARTS MANUAL — REV. #1 (08/10/10) — PAGE 15

Image 15
Contents Model QP-2TE Proposition 65WARNING Page QP- 2TE Table of Contents Ordering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationGeneral Safety Engine Safety Fuel Safety Transporting Safety Page Specifications Pump QP- 2TE SPECIFICATIONS/DIMENSIONS PumpSpecifications Engine Application QP- 2TE General InformationWater QP- 2TE Pump ComponentsPlastic TRUCK-BED Liner QP- 2TE RefuelingInitial Servicing QP- 2TE Basic EngineBefore Starting QP- 2TE PRE-INSPECTION EngineRead safety instructions at the beginning of manual QP- 2TE PRE-SETUP PumpStarting the Engine Robin engine QP- 2TE Initial START-UP EngineQP- 2TE Initial START-UP Engine Pump Vacuum Test QP- 2TE Maintenance PumpQP- 2TE Maintenance Pump Engine Maintenance Schedule QP- 2TE Maintenance EngineQP- 2TE Maintenance Engine Pump Storage QP- 2TE Preparation for Long -TERM StoragePage Engine Troubleshooting QP- 2TE Troubleshooting EngineQP- 2TE Troubleshooting ENGINE/PUMP QP- 2TE Explanation of Code in Remarks Column QP- 2TETRASH Pump 1TO 3 Units Robin EX170D50021 Engine QP- 2TE Suggested Spare PartsQP- 2TE Pump Assy Part Name QTY Remarks QP- 2TE Pump Assy Bolt SET with Spring Washer Suction COVERM8 X QP 2TE Pump AssyRobin EX170D50021 ENGINE- Crankcase Assy Part Name QTY Remarks Robin EX170D50021 ENGINE- Crankshaft and Piston Assy Robin EX170D50021 ENGINE- Crankshaft and Piston Assy Robin EX170D50021 ENGINE- Governor Assy Part Name QTY. Remarks Robin EX170D50021 ENGINE- Intake Exhaust Assy PIN, CAM Shaft Robin EX170D50021 Engine AIR Cleaner Assy Base CP Robin EX170D50021 Engine Cooling and Starting Assy Robin EX170D50021 ENGINE- Cooling and Starting Assy Robin EX170D50021 Engine Carburetor Assy Throttle Valve Robin EX170D50021 Engine Flywheel Assy Part Name QTY Robin EX170D50021 ENGINE- Electric Device Assy OIL Sensor CP Robin EX170D50021 ENGINE- Fueltank Assy Fuel Tank CP Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

Qp-2TE specifications

The Multiquip QP-2TE is a highly regarded option in the realm of portable generators, designed to meet the demands of both commercial and residential applications. Renowned for its reliability and performance, the QP-2TE delivers exceptional power in a compact and user-friendly package.

At the heart of the Multiquip QP-2TE is a durable, high-performance engine that provides 2,000 watts of surge power and 1,600 watts of continuous power. This robust power output is more than sufficient for running essential equipment such as power tools, lighting, and even small appliances. The generator comes equipped with an easy-to-read fuel gauge, allowing users to monitor fuel levels at a glance, ensuring they can operate without interruptions.

The QP-2TE features a versatile power panel with multiple outlets. It includes both 120V and 12V DC outlets, enabling users to connect various devices simultaneously. The inclusion of a 120V, 20A duplex outlet adds to the generator's versatility, allowing it to power multiple tools at once or provide temporary power to an entire campsite. The generator's lightweight construction, weighing only around 45 pounds, ensures portability, making it suitable for outdoor events, job sites, or emergency backup power.

Technologically speaking, the QP-2TE integrates advanced features such as low oil shutdown and circuit protection. These safety mechanisms are crucial as they prevent damage to the engine and connected devices during operation, ensuring longevity and reliability. Its efficient cooling system also aids in preventing overheating, allowing the generator to function optimally for extended periods.

Another standout characteristic of the Multiquip QP-2TE is its whisper-quiet operation. Designed with noise reduction features, it operates at a remarkably low decibel level, making it ideal for use in residential neighborhoods or campgrounds where noise restrictions might be in place. Its fuel-efficient operation enhances its appeal, allowing users to maximize run time on a single tank of gas.

In summary, the Multiquip QP-2TE is a powerful, portable generator that combines rugged durability with advanced safety features and quiet operation. Its versatility, lightweight design, and efficient power output make it an excellent choice for those seeking reliable energy solutions in various settings. Whether for emergency power, outdoor activities, or job site operations, the QP-2TE stands out as a premium option in the portable generator market.