Premier Fire Alarm Control Panel user manual Panel Indications & Controls, General Controls

Page 5

PREMIER SX USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

4. PANEL INDICATIONS & CONTROLS

FIRE / ZONES

1

2

3

4

5

POWER

SUPPLY FLT

 

 

 

FLT

 

 

 

 

 

 

GEN-FIRE

 

DEL ZONAL FAULT / DISABLEMENT / TEST

 

 

1

2

3

4

5

GEN-FAULT

SYSTEM FLT

GEN-S/C

 

 

 

 

STOP-START

SILENCE

RESET

SCROLL /

 

 

 

6

6

7

7

8

8

OFF

CONTROLS ENABLED

1

 

2

 

3

 

4

 

ENGINEER

GEN-ZONE TEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLT TONE

 

 

/ LED TEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GEN-DISABLEMENT DELAY

OVERRIDE

Two levels of control are available to the User(s) of this Fire Alarm Panel.

4.1 GENERAL CONTROLS

When the Panel is in its Normal state, the indicator lights on the front of the enclosure give a comprehensive overview of the System’s current status. Any Fire and Fault conditions are clearly displayed, and any disablements highlighted. For detailed descriptions of what each indicator means, please refer to the table on the opposite page.

The only functions that can be performed by the User when the Panel is in its Normal state are:

Overriding any Delays, which may have been programmed into the Panel by pressing the Sounder Override button.

Putting the Panel into the Accessed state – see below.

4.2ACCESSED CONTROL (AVAILABLE TO AUTHORISED USERS ONLY)

To avoid unauthorised changes to critical parts of the Fire Alarm System, controls such as silencing the Sounders, resetting an Alarm condition and implementing Disablements are only accessible via a secure method of entry which puts the panel into the Accessed state.

To put the Panel into the Accessed State: Turn the key to the control enable position (please note the key should not be removed when in this position). To leave the Accessed state, turn the key back to the off position.

Information on how to used the accessed control can be found on Pages 8 to 11 of this User Manual.

Approved Document No: GLT.MAN-102

PAGE 5

Issue: 1.3 Authorised: GH

Date: 9/6/2004

 

Image 5
Contents Page Purpose of a Fire Alarm SYSTEM……………………………………………… Purpose of a Fire Alarm System Fire Alarm Control Panel Safety IssuesDaily Inspection Responsible person mustGeneral Controls Accessed Control Available to Authorised Users onlyPanel Indications & Controls LED Condition Panel Status Fire Condition HOW the Premier SX Indicates AN Alarm Fire / ZonesBuilding evacuation procedure should now be followed Different Types of Fault Fault ConditionSounder Fault Earth FaultReasons for Disabling Certain Parts of a Fire Alarm System DisablementsTo Disable a Zone AND/OR External Sounders To Enable a Zone AND/OR External SoundersWhat is a Sounder Delay Using Sounder DelaysFire Zone Information Fire Alarm System SummaryFire Alarm LOG Book Maintenance Work False Alarms ALL Events Other than Maintenance Work or False Alarms Commissioning the SYSTEM, Including P.S.E DESIGN, Installation & Commissioning CertificatesName in block letters Installation & Commissioning Recommendations Address Address Address