Starting the Engine (HONDA)

1.Place the engine fuel valve lever (See Figure 6) to the “ON” position.

Figure 6. Engine Fuel Valve Lever (ON Position)

2.Move the throttle lever (See Figure 7) away from the slow position, about 1/3 of the way toward the fast position.

3.Place the choke lever (See Figure 8) in the “CLOSED” position if starting a cold engine.

Figure 8. Engine Choke Lever (Closed)

4.Place the choke lever (See Figure 9) in the “OPEN” position if starting a warm engine or the temperature is warm.

Figure 9. Engine Choke Lever (Open)

5.Place the engine ON/OFF switch (See Figure 10) in the “ON” position.

Figure 7. Throttle Lever (1/3 Start Position)

Figure 10. Engine ON/OFF Switch (ON Position)

QP205SLT/QPT205SLT CENTRIFUGAL PUMP • operation and parts manual — rev. #1 (10/11/10) — page 17

Image 17
Contents Model QP205SLT/QPT205SLT Proposition 65 warning Page QP205SLT/QPT205SLT Table of ContentsChoose from three easy options Safety Information General Safety Always ensure pump is on level ground before use Safety InformationSafety Information SPECIFICATIONS/DIMENSIONS Pump Specifications Engine General information Drain Plug Remove this plug to drain water from the pump Pump componentsINITIAL Servicing Basic engineBefore Starting InspectionEngine Oil Check Fuel CheckHoses and Clamps SET-UPStarting the Engine Honda OperationEmergency Shutdown Stopping the Engine Normal ShutdownPump Vacuum Test Maintenance pumpAdjusting Impeller Clearance Maintenance pump Engine Maintenance Maintenance engineWeekly MaintenanceDaily Pump Storage Preparation for long-term storageSymptom Possible Cause Solution TroubleshootingTroubleshooting Engine Air cleaner dirty? Clean or replace air cleaner Page No. Column Explanation of Code in Remarks ColumnPaRT No. Column QTY. ColumnSuggested Spare Parts Pump Assembly Suction COVER, NPT CasingCheck Valve QP205SLT onlyPump Assembly Lock Washer M8 Bolt M8X20Bolt M8X50 Not Sold SeparatelyHonda GX240K1PMT2/GX240U1PMT2 air cleaner dual assy GROMMET, AIR Cleaner COVER, AIR Cleaner DualCOLLAR, AIR Cleaner Collar B, AIR CleanerHonda GX240K1PMT2/GX240U1PMT2 camshaft assy Includes Item W/# SPRING, Weight ReturnROD, Push ARM, Valve RockerHonda GX240K1PMT2/GX240U1PMT2 carburetor assy Valve SET, Float Includes Item W/ +Float SET Includes Item 4AHonda GX240K1PMT2/GX240U1PMT2 carburetor assy SPACER, Carburetor PLATE, Lever SettingGASKET, Carburetor GASKET, InsulatorHonda GX240K1PMT2/GX240U1PMT2 control assy ARM, Governor SPRING, Control AdjustingROD, Governor SPRING, GovernorHonda GX240K1PMT2/GX240U1PMT2 crankcase cover assy HOLDER, Governor Weight WEIGHT, GovernorPIN, Governor Weight GASKET, Case CoverHonda GX240K1PMT2/GX240U1PMT2 crankshaft assy KEY, Special Woodruff Honda GX240K1PMT2/GX240U1PMT2 cylinder barrel assy NUT, Flange 10MM Switch ASSEMBLY, OIL LevelRING, 14MM NOK PIN, Lock 10MMHonda GX240K1PMT2/GX240U1PMT2 cylinder head assy GUIDE, Exhaust Valve OS OPT GUIDE, Valve OS OptionalCLIP, Valve Guide GASKET, Cylinder HeadHonda GX240K1PMT2/GX240U1PMT2 fan cover assy CLIP, Wire Harness Switch ASSY., Engine StopCLIP, Tube COVER, FAN *NH1* BlackHonda GX240K1PMT2/GX240U1PMT2 flywheel assy FAN, Cooling FLYWHEEL, CompletePULLEY, Starter Screen Grid NUT, Special 16MMHonda GX240K1PMT2/GX240U1PMT2 fuel tank assy JOINT, Fuel Tank RUBBER, Supporter 107MMTANK, Fuel *NH1* Black GASKET, Fuel Filler CAPHonda GX240K1PMT2/GX240U1PMT2 ignition coil assy Coil ASSY., Ignition WIRE, Stop Switch 370 MMGROMMET, Cord CLIP, HarnessHonda GX240K1PMT2/GX240U1PMT2 muffler assy PIPE, Exhaust Muffler SilentGASKET, Exhaust Pipe FLANGE, BaffleHonda GX240K1PMT2/GX240U1PMT2 piston assy BOLT, Connecting ROD ROD ASSY., ConnectingRing SET, Piston STD Ring SET, PistonHonda GX240K1PMT2/GX240U1PMT2 recoil starter assy RACHET, Starter PULLEY, Recoil StarterSPRING, Friction SPRING, Starter ReturnHonda GX240K1PMT2/GX240U1PMT2 gASKET KIT 061A1ZE2040 Honda GX240K1PMT2/GX240U1PMT2 Labels Assy MARK, Choke Orange MARK, Throttle IndicationMARK, Choke Gray LABEL, CautionFreight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

QPT205SLT, QP205SLT specifications

The Multiquip QPT205SLT and QP205SLT are robust generators designed to provide reliable power solutions for a variety of applications, including construction sites, outdoor events, and emergency power needs. Known for their durability and user-friendly features, these models stand out in the competitive generator market.

One of the main features of both the QPT205SLT and QP205SLT is their powerful engine. Equipped with a reliable four-stroke engine, these generators deliver a peak output of 20 kW, making them suitable for demanding power requirements. This output capability allows users to run multiple tools and appliances simultaneously without compromising performance. The generators are also designed to be fuel-efficient, offering extended run times that reduce the need for frequent refueling.

Another characteristic that sets these models apart is their portability. The QPT205SLT and QP205SLT feature a compact design coupled with sturdy wheels and a folding handle, enabling easy transportation across various terrains. Whether moving from job site to job site or simply relocating within a more limited space, the mobility of these generators is a significant advantage.

In terms of technology, Multiquip has incorporated advanced noise-reduction systems in both models. The generators are equipped with sound-attenuated enclosures that help minimize operational noise, making them suitable for use in noise-sensitive environments. The low noise levels not only enhance user comfort but also comply with local regulations regarding noise emissions.

Safety features are also prominent in these generators. Both the QPT205SLT and QP205SLT come with protective covers and automatic shut-off systems that prevent overheating and ensure safe operation. Furthermore, they include circuit breakers that offer an additional layer of protection against electrical overloads.

The user interface of the QPT205SLT and QP205SLT is designed for simplicity. With easy-to-read gauges and intuitive controls, operators can monitor fuel levels, output voltage, and other critical parameters without hassle. This user-centric design makes it accessible for both seasoned professionals and those less experienced with generator operation.

Overall, the Multiquip QPT205SLT and QP205SLT are engineered to meet the needs of various users looking for reliable, efficient, and portable power solutions. Their combination of power, portability, noise reduction, and safety features makes them a top choice for professionals across many industries.