Multiquip QPT205SLT, QP205SLT Maintenance pump, Pump Vacuum Test, Adjusting Impeller Clearance

Page 19

maintenance (pump)

Pump Vacuum Test

CAUTION

DO NOT attempt to start the engine unless the pump has previously been primed with water. Severe pump damage will occur if pump has not been primed.

To perform the pump vacuum test do the following:

1.Remove the pump fill cap (See Figure 2), and fill the pump with water.

2.Start the engine as outlined in the initial start-up section, and wait for the pump to begin pumping.

3.As shown in Figure 17, place a water hose inside the discharge opening of the pump, and turn on the water. This flow of water into the discharge opening will prevent the pump from running dry.

4.Place the Pump Vacuum Tester (P/N 7000030) over the pump suction (inlet) opening (See Figure 17) with the vacuum gauge facing upwards. It may be necessary to apply a small amount of water around the rubber seal of the vacuum tester to make a good suction fit.

5.Check and make sure that there are no air leaks between the vacuum tester and the inlet port on the pump. If air leaks are present reseat vacuum tester.

6.Run the pump for a few minutes while monitoring the vacuum gauge. If the gauge indicates a reading between -25 and -20 in. Hg. (inches of mercury) then it can be assumed that the pump is working correctly.

NOTICE

25 in. Hg (inches of mercury) translates into 25 feet of lift at sea level.

7.If the vacuum tester gauge indicates a reading below -20 in. Hg, it can then be assumed that the pump is not functioning correctly, and corrective action needs to be taken.

8.To test the flapper valve, shutdown the engine. The vacuum tester should remain attached to the pump suction inlet port by vacuum.This indicates the pump's flapper valve is seating properly to hold water in the suction hose when the engine is stopped.This prevents backflow and allows for faster priming when the engine is restarted.

Adjusting Impeller Clearance

1.If it is necessary to replace impeller or volute, be sure clearance between impeller and volute is adjusted correctly.

2.The impeller should be as close to the volute as possible without rubbing against it. Clearance is adjusted by adding or removing shims from behind the impeller.

3.Check clearance between impeller and insert by slowly pulling starter rope to turn impeller. Remove spark plug to make it easier to turn impeller.

NOTICE

QP205SLT Only - It is important not to remove too many shims or the clearance between the impeller and volute will become too wide and pump performance will be reduced. Remember as the impeller wears down, additional shims may be required to maintain the clearance between the impeller and insert.

4.Check the impeller every six months for wear, and for clearance between the impeller face and the volute. Also check the shaft seal for wear, as well as the shaft sleeve.

CAUTION

The impeller may develop sharp edges. Use extreme care when checking the impeller to prevent being cut.

QP205SLT/QPT205SLT CENTRIFUGAL PUMP • operation and parts manual — rev. #1 (10/11/10) — page 19

Image 19
Contents Model QP205SLT/QPT205SLT Proposition 65 warning Page QP205SLT/QPT205SLT Table of ContentsChoose from three easy options Safety Information General Safety Always ensure pump is on level ground before use Safety InformationSafety Information SPECIFICATIONS/DIMENSIONS Pump Specifications Engine General information Drain Plug Remove this plug to drain water from the pump Pump componentsINITIAL Servicing Basic engineFuel Check InspectionBefore Starting Engine Oil CheckHoses and Clamps SET-UPStarting the Engine Honda OperationEmergency Shutdown Stopping the Engine Normal ShutdownAdjusting Impeller Clearance Maintenance pumpPump Vacuum Test Maintenance pump Engine Maintenance Maintenance engineDaily MaintenanceWeekly Pump Storage Preparation for long-term storageSymptom Possible Cause Solution TroubleshootingTroubleshooting Engine Air cleaner dirty? Clean or replace air cleaner Page QTY. Column Explanation of Code in Remarks ColumnNo. Column PaRT No. ColumnSuggested Spare Parts Pump Assembly QP205SLT only CasingSuction COVER, NPT Check ValvePump Assembly Not Sold Separately Bolt M8X20Lock Washer M8 Bolt M8X50Honda GX240K1PMT2/GX240U1PMT2 air cleaner dual assy Collar B, AIR Cleaner COVER, AIR Cleaner DualGROMMET, AIR Cleaner COLLAR, AIR CleanerHonda GX240K1PMT2/GX240U1PMT2 camshaft assy ARM, Valve Rocker SPRING, Weight ReturnIncludes Item W/# ROD, PushHonda GX240K1PMT2/GX240U1PMT2 carburetor assy Includes Item 4A Includes Item W/ +Valve SET, Float Float SETHonda GX240K1PMT2/GX240U1PMT2 carburetor assy GASKET, Insulator PLATE, Lever SettingSPACER, Carburetor GASKET, CarburetorHonda GX240K1PMT2/GX240U1PMT2 control assy SPRING, Governor SPRING, Control AdjustingARM, Governor ROD, GovernorHonda GX240K1PMT2/GX240U1PMT2 crankcase cover assy GASKET, Case Cover WEIGHT, GovernorHOLDER, Governor Weight PIN, Governor WeightHonda GX240K1PMT2/GX240U1PMT2 crankshaft assy KEY, Special Woodruff Honda GX240K1PMT2/GX240U1PMT2 cylinder barrel assy PIN, Lock 10MM Switch ASSEMBLY, OIL LevelNUT, Flange 10MM RING, 14MM NOKHonda GX240K1PMT2/GX240U1PMT2 cylinder head assy GASKET, Cylinder Head GUIDE, Valve OS OptionalGUIDE, Exhaust Valve OS OPT CLIP, Valve GuideHonda GX240K1PMT2/GX240U1PMT2 fan cover assy COVER, FAN *NH1* Black Switch ASSY., Engine StopCLIP, Wire Harness CLIP, TubeHonda GX240K1PMT2/GX240U1PMT2 flywheel assy NUT, Special 16MM FLYWHEEL, CompleteFAN, Cooling PULLEY, Starter Screen GridHonda GX240K1PMT2/GX240U1PMT2 fuel tank assy GASKET, Fuel Filler CAP RUBBER, Supporter 107MMJOINT, Fuel Tank TANK, Fuel *NH1* BlackHonda GX240K1PMT2/GX240U1PMT2 ignition coil assy CLIP, Harness WIRE, Stop Switch 370 MMCoil ASSY., Ignition GROMMET, CordHonda GX240K1PMT2/GX240U1PMT2 muffler assy FLANGE, Baffle Muffler SilentPIPE, Exhaust GASKET, Exhaust PipeHonda GX240K1PMT2/GX240U1PMT2 piston assy Ring SET, Piston ROD ASSY., ConnectingBOLT, Connecting ROD Ring SET, Piston STDHonda GX240K1PMT2/GX240U1PMT2 recoil starter assy SPRING, Starter Return PULLEY, Recoil StarterRACHET, Starter SPRING, FrictionHonda GX240K1PMT2/GX240U1PMT2 gASKET KIT 061A1ZE2040 Honda GX240K1PMT2/GX240U1PMT2 Labels Assy LABEL, Caution MARK, Throttle IndicationMARK, Choke Orange MARK, Choke GrayFreight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

QPT205SLT, QP205SLT specifications

The Multiquip QPT205SLT and QP205SLT are robust generators designed to provide reliable power solutions for a variety of applications, including construction sites, outdoor events, and emergency power needs. Known for their durability and user-friendly features, these models stand out in the competitive generator market.

One of the main features of both the QPT205SLT and QP205SLT is their powerful engine. Equipped with a reliable four-stroke engine, these generators deliver a peak output of 20 kW, making them suitable for demanding power requirements. This output capability allows users to run multiple tools and appliances simultaneously without compromising performance. The generators are also designed to be fuel-efficient, offering extended run times that reduce the need for frequent refueling.

Another characteristic that sets these models apart is their portability. The QPT205SLT and QP205SLT feature a compact design coupled with sturdy wheels and a folding handle, enabling easy transportation across various terrains. Whether moving from job site to job site or simply relocating within a more limited space, the mobility of these generators is a significant advantage.

In terms of technology, Multiquip has incorporated advanced noise-reduction systems in both models. The generators are equipped with sound-attenuated enclosures that help minimize operational noise, making them suitable for use in noise-sensitive environments. The low noise levels not only enhance user comfort but also comply with local regulations regarding noise emissions.

Safety features are also prominent in these generators. Both the QPT205SLT and QP205SLT come with protective covers and automatic shut-off systems that prevent overheating and ensure safe operation. Furthermore, they include circuit breakers that offer an additional layer of protection against electrical overloads.

The user interface of the QPT205SLT and QP205SLT is designed for simplicity. With easy-to-read gauges and intuitive controls, operators can monitor fuel levels, output voltage, and other critical parameters without hassle. This user-centric design makes it accessible for both seasoned professionals and those less experienced with generator operation.

Overall, the Multiquip QPT205SLT and QP205SLT are engineered to meet the needs of various users looking for reliable, efficient, and portable power solutions. Their combination of power, portability, noise reduction, and safety features makes them a top choice for professionals across many industries.