Multiquip QPT205SLT, QP205SLT manual General Safety

Page 7

SAFETY INFORMATION

GENERAL SAFETY

„DO NOT operate or service this equipment before reading the entire manual. The equipment is to be operated by trained and qualified personnel only! The equipment is

for industrial use only.

„This equipment should not be operated by persons under 18 years of age.

„NEVER operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, hearing protection, steel-toed boots and other protective devices required by the job.

„ NEVER operate this equipment when not feeling well due to fatigue, illness or when under medication.

„NEVER operate this equipment under the influence of drugs or alcohol.

„NEVER disconnect any “emergency or safety devices.”These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death! Disconnection of any of these devices will void all warranties.

„NEVER use accessories or attachments that are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.

„Manufacturer does not assume responsibility for any accident due to equipment modifications. Unauthorized equipment modification will void all warranties.

„Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.

„ALWAYS check the equipment for loosened threads or bolts before starting.

„NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing engine or pump. Never

operate the engine with heat shields or guards removed.

„ALWAYS allow the engine to cool before adding fuel or performing service and maintenance functions. Contact with hot components can cause serious burns.

„NEVER operate this equipment in any enclosed or narrow area where free flow of the air is restricted. The engine of this equipment requires an adequate free flow of cooling air. If the air flow is restricted it will cause serious damage to the equipment or

engine and may cause injury to people and property. The

engine fuel exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause death if inhaled.

„ALWAYS refuel in a well-ventilated area, away from sparks and open flames. DO NOT fill the fuel tank while the engine is running or hot. DO NOT overfill tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system. Store fuel in approved containers.

„ALWAYS use extreme caution when working with flammable liquids.When refueling, stop the engine and allow it to cool.

„DO NOT smoke around or near the equipment. Fire or explosion could result

from fuel vapors, or if fuel is spilled on a hot engine.

„NEVER operate the equipment in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

„ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

QP205SLT/QPT205SLT CENTRIFUGAL PUMP • operation and parts manual — rev. #1 (10/11/10) — page 7

Image 7
Contents Model QP205SLT/QPT205SLT Proposition 65 warning Page QP205SLT/QPT205SLT Table of ContentsChoose from three easy options Safety Information General Safety Always ensure pump is on level ground before use Safety InformationSafety Information SPECIFICATIONS/DIMENSIONS Pump Specifications Engine General information Drain Plug Remove this plug to drain water from the pump Pump componentsINITIAL Servicing Basic engineFuel Check InspectionBefore Starting Engine Oil CheckHoses and Clamps SET-UPStarting the Engine Honda OperationEmergency Shutdown Stopping the Engine Normal ShutdownAdjusting Impeller Clearance Maintenance pumpPump Vacuum Test Maintenance pump Engine Maintenance Maintenance engineDaily MaintenanceWeekly Pump Storage Preparation for long-term storageSymptom Possible Cause Solution TroubleshootingTroubleshooting Engine Air cleaner dirty? Clean or replace air cleaner Page QTY. Column Explanation of Code in Remarks ColumnNo. Column PaRT No. ColumnSuggested Spare Parts Pump Assembly QP205SLT only CasingSuction COVER, NPT Check ValvePump Assembly Not Sold Separately Bolt M8X20Lock Washer M8 Bolt M8X50Honda GX240K1PMT2/GX240U1PMT2 air cleaner dual assy Collar B, AIR Cleaner COVER, AIR Cleaner DualGROMMET, AIR Cleaner COLLAR, AIR CleanerHonda GX240K1PMT2/GX240U1PMT2 camshaft assy ARM, Valve Rocker SPRING, Weight ReturnIncludes Item W/# ROD, PushHonda GX240K1PMT2/GX240U1PMT2 carburetor assy Includes Item 4A Includes Item W/ +Valve SET, Float Float SETHonda GX240K1PMT2/GX240U1PMT2 carburetor assy GASKET, Insulator PLATE, Lever SettingSPACER, Carburetor GASKET, CarburetorHonda GX240K1PMT2/GX240U1PMT2 control assy SPRING, Governor SPRING, Control AdjustingARM, Governor ROD, GovernorHonda GX240K1PMT2/GX240U1PMT2 crankcase cover assy GASKET, Case Cover WEIGHT, GovernorHOLDER, Governor Weight PIN, Governor WeightHonda GX240K1PMT2/GX240U1PMT2 crankshaft assy KEY, Special Woodruff Honda GX240K1PMT2/GX240U1PMT2 cylinder barrel assy PIN, Lock 10MM Switch ASSEMBLY, OIL LevelNUT, Flange 10MM RING, 14MM NOKHonda GX240K1PMT2/GX240U1PMT2 cylinder head assy GASKET, Cylinder Head GUIDE, Valve OS OptionalGUIDE, Exhaust Valve OS OPT CLIP, Valve GuideHonda GX240K1PMT2/GX240U1PMT2 fan cover assy COVER, FAN *NH1* Black Switch ASSY., Engine StopCLIP, Wire Harness CLIP, TubeHonda GX240K1PMT2/GX240U1PMT2 flywheel assy NUT, Special 16MM FLYWHEEL, CompleteFAN, Cooling PULLEY, Starter Screen GridHonda GX240K1PMT2/GX240U1PMT2 fuel tank assy GASKET, Fuel Filler CAP RUBBER, Supporter 107MMJOINT, Fuel Tank TANK, Fuel *NH1* BlackHonda GX240K1PMT2/GX240U1PMT2 ignition coil assy CLIP, Harness WIRE, Stop Switch 370 MMCoil ASSY., Ignition GROMMET, CordHonda GX240K1PMT2/GX240U1PMT2 muffler assy FLANGE, Baffle Muffler SilentPIPE, Exhaust GASKET, Exhaust PipeHonda GX240K1PMT2/GX240U1PMT2 piston assy Ring SET, Piston ROD ASSY., ConnectingBOLT, Connecting ROD Ring SET, Piston STDHonda GX240K1PMT2/GX240U1PMT2 recoil starter assy SPRING, Starter Return PULLEY, Recoil StarterRACHET, Starter SPRING, FrictionHonda GX240K1PMT2/GX240U1PMT2 gASKET KIT 061A1ZE2040 Honda GX240K1PMT2/GX240U1PMT2 Labels Assy LABEL, Caution MARK, Throttle IndicationMARK, Choke Orange MARK, Choke GrayFreight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

QPT205SLT, QP205SLT specifications

The Multiquip QPT205SLT and QP205SLT are robust generators designed to provide reliable power solutions for a variety of applications, including construction sites, outdoor events, and emergency power needs. Known for their durability and user-friendly features, these models stand out in the competitive generator market.

One of the main features of both the QPT205SLT and QP205SLT is their powerful engine. Equipped with a reliable four-stroke engine, these generators deliver a peak output of 20 kW, making them suitable for demanding power requirements. This output capability allows users to run multiple tools and appliances simultaneously without compromising performance. The generators are also designed to be fuel-efficient, offering extended run times that reduce the need for frequent refueling.

Another characteristic that sets these models apart is their portability. The QPT205SLT and QP205SLT feature a compact design coupled with sturdy wheels and a folding handle, enabling easy transportation across various terrains. Whether moving from job site to job site or simply relocating within a more limited space, the mobility of these generators is a significant advantage.

In terms of technology, Multiquip has incorporated advanced noise-reduction systems in both models. The generators are equipped with sound-attenuated enclosures that help minimize operational noise, making them suitable for use in noise-sensitive environments. The low noise levels not only enhance user comfort but also comply with local regulations regarding noise emissions.

Safety features are also prominent in these generators. Both the QPT205SLT and QP205SLT come with protective covers and automatic shut-off systems that prevent overheating and ensure safe operation. Furthermore, they include circuit breakers that offer an additional layer of protection against electrical overloads.

The user interface of the QPT205SLT and QP205SLT is designed for simplicity. With easy-to-read gauges and intuitive controls, operators can monitor fuel levels, output voltage, and other critical parameters without hassle. This user-centric design makes it accessible for both seasoned professionals and those less experienced with generator operation.

Overall, the Multiquip QPT205SLT and QP205SLT are engineered to meet the needs of various users looking for reliable, efficient, and portable power solutions. Their combination of power, portability, noise reduction, and safety features makes them a top choice for professionals across many industries.