PUMP COMPONENTS
Figure 2 shows a typical application using the QP2E centrifugal pump. Please note that this pump is intended for the removal of clean water.
Figure 2. QP2E Pump Application
1.Pump — A
2.Fill Cap — Prior to operation, the pump casing should be fi lled with water. Remove this cap to add water to the pump. After the initial prime, a suffi cient amount of water will be retained in the casing so that the operator will not need to
If the casing is dry or has insuffi cient water, the pump will have difficulty in priming which could lead to premature mechanical seal wear thus causing damage to the pump.
3.Discharge Port — Connect a
4.Worm Clamp — Used to secure the hose to the inlet and outlet ports on the pump. Use two clamps to secure the hose on the inlet side of the pump.
5.Discharge Hose — Connect this flexible rubber hose to the discharge port on the pump. Make sure that the hose lays fl at and is not kinked. Use only recommended type discharge hose. Contact Multiquip parts department for ordering information.
6.Suction Port — Connect a
7.Suction Hose — Connect this fl exible rubber hose to the suction port on the pump. Make sure that the hose lays flat and is not kinked. Use only recommended type suction hose. Contact Multiquip Parts Department for ordering information.
8.Drain Plug — Remove this plug to drain water from the pump.
9.Strainer — Always attach a strainer to bottom side of the suction hose to prevent large objects and debris from entering the pump. Strainer should be positioned so that it will remain completely under water. Running the pump with the strainer above water for long periods can damage pump.