S-500 SERIES SUB. PUMP OPERATION

Hose Connections

1.Connect a 2-inch hose to the discharge port on the pump as shown in Figure 8. Make sure that the hose is attached correctly to the discharge port.

Pump Power Connections (Piggy-Back Cord Only)

1.Make sure the circuit breaker supplying power to the pump is in the OFF position.

2.Connect the float switch or switches to the AC power receptacle as shown in Figure 6.

Attaching Lifting Rope

1.Attach a suitable lifting cable (rope) to the carrying handle (Figure 8) on the pump and lower the pump into place. For applications where there is an excessive amount of mud, grit or silt, the use of a support platform is desirable. When pumping water from swimming pool type applications where thereislittleornodebris,thesupportplatformisnotrequired.

Figure 9. Submersible Pump Upright Position

(Incorrect)

3.If all of the pump's electrical requirements have been met, place thecircuit breaker or powerON/OFF switchintheON position.

4.Wait a few seconds and water should begin to flow from the discharge hose.

5.If water is not flowing from the discharge hose or not flowing freely after a few minutes, remove the power from the pump and check the system for leaks.

6.To stop the pump from pumping, place the circuit breaker or ON/OFF switch in the OFF position.

DANGER

NEVER! grab or touch a live power cord (Figure 10). DO NOT stand in water when connecting the pump's power cord into a voltage source. The possibility exists of electrical shock, electrocution and possibly death!

WET

HANDS

Figure 8. Submersible Pump Upright Position

(Correct)

2.Make sure the pump is always placed in an upright position, nottilted(Figure9).Neverpositionthepumpdirectlyonasoft, loose bottom. Remember to attain maximum pumping ca- pacity and prevent excessive wear, position the pump so it will not burrow itself into sand or clay.

POWER

CORD

(POWER ON)

Figure 10. Power Cord (Wet Hands)

S-500 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #0 (10/01/04) — PAGE 15

Image 15
Contents Submersible Pumps Model S-500 Series Heres HOW to GET Help Series SUB. Pump Table of Contents When ordering parts Please supply the following information Series SUB. Pump Parts Ordering ProceduresFor Your Safety and the Safety of Others Series SUB. Pump Safety Message Alert SymbolsSeries SUB. Pump Rules for Safe Operation General SafetyEmergencies Maintenance Safety500P, S-500UL Dimensions Series SUB. Pump DimensionsSpecifications Series SUB. Pump SpecificationsControl Box Installation Warnings Series SUB. Pump General InformationIntroduction Submersible Pump Components Series SUB. Pump ComponentsHow It Works Series SUB. Pump Float SwitchesFloat Switch Theory Design FeaturesSeries SUB. Pump Float Switch PIGGY-BACK Float SwitchMounting The Float Switch Control Box CB3 Series SUB. Pump Float Switch Control BOXAttaching Lifting Rope Pump Power Connections Piggy-Back Cord OnlySeries SUB. Pump Operation Hose ConnectionsConnecting Dual float Switch SW-1WOP To Control Box Series SUB. PUMP- Control BOX InstallationSingle-Phase Power Installation Input Power Cord RequirementsSeries SUB. PUMP- Control BOX Installation Connecting AC Power to the Control BoxConnecting AC Power to the Pump Pump Shut-Down/Clean-up Series SUB. Pump CLEAN-UPChecking Hydraulic Oil Series SUB. Pump MaintenancePump Troubleshooting Series SUB. Pump -TROUBLESHOOTINGPump Performance Curves Series SUB. Pump Performance CurvesControl BOX Wiring Diagram Series SUB. Pump Wiring DiagramsPage Series SUB. Pump Explanation of Code in Remarks How to read the marks and remarks used in this parts500P/UL Submersible Pump 1 to 3 Units Series SUB. Pump Suggested Spare Parts500P, S-500UL, S-500CE Submersible Pump Assy 500P/UL/CE Electric Submersible Pump AssyPart Name QTY Remark 500P/UL/CE Electric Submersible Pump Assy Bolt 500P/UL Electric Motor Assy Part Name 500CE Electric Motor Assy 157-1 020S500CE1571 Effective October 1, 2002 Terms and Conditions of Sale Parts Page Your Local Dealer is

S-500 specifications

The Multiquip S-500 is a robust and versatile power source designed for a variety of construction and industrial applications. This silent diesel generator has gained popularity due to its exceptional performance, durability, and advanced features. Built with the needs of contractors and businesses in mind, the S-500 provides a reliable solution for energy generation on job sites, events, and emergency power situations.

One of the standout features of the Multiquip S-500 is its powerful Kubota diesel engine. This engine is engineered for efficiency, delivering an output of 500 kVA, making it suitable for heavy-duty tasks. The S-500 is designed to operate under challenging conditions, ensuring that it can handle the demands of any project while providing a steady stream of power.

Performance is further enhanced by the advanced control panel, which features digital monitoring technology. This intuitive interface allows users to easily track performance metrics, including voltage, frequency, and operating hours. Additionally, it supports remote monitoring capabilities, enabling users to manage the generator from a distance and ensuring proactive maintenance.

The S-500 also emphasizes fuel efficiency. Equipped with a large, integrated fuel tank, it allows for extended operation times between refueling, reducing downtime and operational costs. Furthermore, its design minimizes emissions, adhering to stringent environmental regulations, making it an eco-friendly option for users concerned about sustainability.

Durability is another hallmark of the Multiquip S-500. Constructed with high-quality materials and featuring a weather-resistant enclosure, this generator withstands the rigors of outdoor use. Coupled with a solid transport frame, it is easy to move and set up in any location.

Safety features are integral to the S-500’s design, with auto-shutdown capabilities for low oil pressure, overloading, and overheating. These precautions ensure that users can operate the generator with confidence, reducing the risk of equipment damage and promoting a safer work environment.

In summary, the Multiquip S-500 is a powerful, efficient, and durable generator optimized for demanding applications. With advanced technologies and user-friendly controls, it meets the needs of modern contractors and businesses while providing a reliable source of power wherever it’s needed. Whether for construction, events, or emergency backup, the S-500 stands as a testament to Multiquip's commitment to quality and innovation in power generation.