Multiquip S-500 manual Series SUB. Pump Safety Message Alert Symbols

Page 5

S-500 SERIES SUB. PUMP — SAFETY MESSAGE ALERT SYMBOLS

FOR YOUR SAFETY AND THE SAFETY OF OTHERS!

Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others.

This Owner's Manual has been developed to provide complete instructions for the safe and efficient

NOTEoperation of the Multiquip

Model S-500 Series Submersible Pumps. Before using these pumps, ensure that the operating individual has read and understands all instructions in this manual.

SAFETY MESSAGE ALERT SYMBOLS

The three (3) Safety Messages shown below will inform you about potential hazards that could injure you or others. The Safety Messages specifically address the level of exposure to the operator, and are preceded by one of three words: DANGER, WARNING, or CAUTION.

HAZARD SYMBOLS

Rotating Parts

NEVER operate equipment with covers, or guards removed. Keep fingers, hands, hair and clothing away from all moving parts to prevent injury.

Accidental Starting

ALWAYS place the power source circuit breaker or ON/OFF switch in the OFF position, when the pump is not in use.

Sight and Hearing hazard

DANGER

You WILL be KILLED or SERIOUSLY injured if you DO NOT follow directions.

WARNING

You CAN be KILLED or SERIOUSLY injured if you DO NOT follow directions.

CAUTION

You CAN be INJURED if you DO NOT follow directions.

Potential hazards associated with the S-500 series submersible pumps operation will be referenced with Hazard Symbols which appear throughout this manual, and will be referenced in conjunction with Safety Message Alert Symbols.

ALWAYS wear approved eye and hearing protection, if required.

Respiratory Hazard

ALWAYS wear approved respiratory protection, if required.

Equipment Damage Messages

Other important messages are provided throughout this manual to help prevent damage to your submersible pump, other property, or the surrounding environment.

This submersible pump, other property, or the surrounding

NOTEenvironment could be damaged if you do not follow instructions.

S-500 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #0 (10/01/04) — PAGE 5

Image 5
Contents Submersible Pumps Model S-500 Series Heres HOW to GET Help Series SUB. Pump Table of Contents When ordering parts Please supply the following information Series SUB. Pump Parts Ordering ProceduresFor Your Safety and the Safety of Others Series SUB. Pump Safety Message Alert SymbolsSeries SUB. Pump Rules for Safe Operation General SafetyEmergencies Maintenance Safety500P, S-500UL Dimensions Series SUB. Pump DimensionsSpecifications Series SUB. Pump SpecificationsIntroduction Control Box Installation WarningsSeries SUB. Pump General Information Submersible Pump Components Series SUB. Pump ComponentsFloat Switch Theory Series SUB. Pump Float SwitchesDesign Features How It WorksMounting The Float Switch Series SUB. Pump Float Switch PIGGY-BACKFloat Switch Control Box CB3 Series SUB. Pump Float Switch Control BOXSeries SUB. Pump Operation Pump Power Connections Piggy-Back Cord OnlyHose Connections Attaching Lifting RopeSingle-Phase Power Installation Input Series SUB. PUMP- Control BOX InstallationPower Cord Requirements Connecting Dual float Switch SW-1WOP To Control BoxConnecting AC Power to the Pump Series SUB. PUMP- Control BOX InstallationConnecting AC Power to the Control Box Pump Shut-Down/Clean-up Series SUB. Pump CLEAN-UPChecking Hydraulic Oil Series SUB. Pump MaintenancePump Troubleshooting Series SUB. Pump -TROUBLESHOOTINGPump Performance Curves Series SUB. Pump Performance CurvesControl BOX Wiring Diagram Series SUB. Pump Wiring DiagramsPage Series SUB. Pump Explanation of Code in Remarks How to read the marks and remarks used in this parts500P/UL Submersible Pump 1 to 3 Units Series SUB. Pump Suggested Spare Parts500P, S-500UL, S-500CE Submersible Pump Assy 500P/UL/CE Electric Submersible Pump AssyPart Name QTY Remark 500P/UL/CE Electric Submersible Pump Assy Bolt 500P/UL Electric Motor Assy Part Name 500CE Electric Motor Assy 157-1 020S500CE1571 Effective October 1, 2002 Terms and Conditions of Sale Parts Page Your Local Dealer is

S-500 specifications

The Multiquip S-500 is a robust and versatile power source designed for a variety of construction and industrial applications. This silent diesel generator has gained popularity due to its exceptional performance, durability, and advanced features. Built with the needs of contractors and businesses in mind, the S-500 provides a reliable solution for energy generation on job sites, events, and emergency power situations.

One of the standout features of the Multiquip S-500 is its powerful Kubota diesel engine. This engine is engineered for efficiency, delivering an output of 500 kVA, making it suitable for heavy-duty tasks. The S-500 is designed to operate under challenging conditions, ensuring that it can handle the demands of any project while providing a steady stream of power.

Performance is further enhanced by the advanced control panel, which features digital monitoring technology. This intuitive interface allows users to easily track performance metrics, including voltage, frequency, and operating hours. Additionally, it supports remote monitoring capabilities, enabling users to manage the generator from a distance and ensuring proactive maintenance.

The S-500 also emphasizes fuel efficiency. Equipped with a large, integrated fuel tank, it allows for extended operation times between refueling, reducing downtime and operational costs. Furthermore, its design minimizes emissions, adhering to stringent environmental regulations, making it an eco-friendly option for users concerned about sustainability.

Durability is another hallmark of the Multiquip S-500. Constructed with high-quality materials and featuring a weather-resistant enclosure, this generator withstands the rigors of outdoor use. Coupled with a solid transport frame, it is easy to move and set up in any location.

Safety features are integral to the S-500’s design, with auto-shutdown capabilities for low oil pressure, overloading, and overheating. These precautions ensure that users can operate the generator with confidence, reducing the risk of equipment damage and promoting a safer work environment.

In summary, the Multiquip S-500 is a powerful, efficient, and durable generator optimized for demanding applications. With advanced technologies and user-friendly controls, it meets the needs of modern contractors and businesses while providing a reliable source of power wherever it’s needed. Whether for construction, events, or emergency backup, the S-500 stands as a testament to Multiquip's commitment to quality and innovation in power generation.