NEVER run engine without air cleaner. Severe engine damage may occur.

ALWAYS read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using pump.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

NEVER leave the pump unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

NEVER pump volatile, explosive, flammable or low flash point fluids.These fluids could ignite or explode.

NEVER operate the pump in an explosive atmosphere.

Before starting the pump, check that the clean-out cover is securely fasten.

ALWAYS ensure pump is on level ground before use.

Become familiar with the components of the pump before operating.

ALWAYS replace any worn or damaged warning decals.

NEVER pump corrosive chemicals or water containing toxic substances. These fluids could create serious health and environmental hazards. Contact local authorities for assistance.

NEVER open the priming plug when pump is hot. Hot water inside could be pressurized much like the radiator of an automobile. Allow pump to cool to the touch before loosening plug. The possibility exists of scalding, resulting in severe bodily harm.

NEVER open the pump housing during operation or start the pump with the clean-out cover removed. The rotating impeller inside the pump can cut or sever objects caught in it.

NEVER block or restrict flow from discharge hose. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat.

ALWAYS fill the pump casing with water before starting the engine. Failure to maintain water inside the pump housing will cause severe damage to the pump.

In winter drain water from pump housing to prevent freezing.

Maintenance Safety:

NEVER lubricate components or attempt service on a running machine.

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

Dispose of hazardous waste properly. Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

TRANSPORTING

ALWAYS shutdown engine before transporting.

Tighten fuel tank cap securely and close fuel cock to prevent fuel from spilling.

Drain fuel when transporting pump over long distances or bad roads.

ALWAYS tie down the pump during transportation by securing the pump's guard frame with rope.

EMERGENCIES

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest first aid kit.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in case of an emergency.

NEVER disconnect any "emergency or safety devices". These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death! Disconnection of any of these devices will void all warranties.

QP-402H CENTRIFUGAL PUMP — OPERATION AND PARTS MANUAL— REV. #1 (04/02/08) — PAGE 9

Image 9
Contents Model QP-402H Centrifugal Pump Proposition 65WARNING Page Table of Contents Ordering parts has never been easier Parts Ordering ProceduresFor Your Safety and the Safety of Others QP-402H Safety Message Alert SymbolsAlways wear approved eye and hearing protection QP-402H Safety Message Alert SymbolsQP-402H Rules for Safe Operation QP-402H Rules for Safe Operation Maintenance SafetyQP-402H SPECIFICATIONS/DIMENSIONS Pump Specifications PumpQP-402H SPECIFICATIONS/DIMENSIONS Engine Specifications EnginesApplication QP-402H General InformationQP-402H Pump Components Plastic TRUCK-BED Liner QP-402H RefuelingInitial Servicing QP-402H Basic EnginePre-Inspection Engine QP-402H PRE-INSPECTION EngineQP-402H PRE-SETUP Pump QP-402H Initial START-UP Engine Normal Shutdown QP-402H Initial START-UP EnginePump Vacuum Test QP-402H Maintenance PumpQP-402H Maintenance Pump Engine Maintenance Schedule QP-402H Maintenance EngineDaily QP-402H Maintenance EnginePump Storage QP-402H Preparation for Long -TERM StoragePage Engine Troubleshooting QP-402H Troubleshooting EngineEngine Troubleshooting QP-402H Troubleshooting ENGINE/PUMPQP-402H Explanation of Code in Remarks Column Sample Parts ListQP-402H Suggested Spare Parts Pump Assy QP-402H Pump AssySuction Cover CasingVolute Casing BaseAIR Cleaner Dual Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. AIR Cleaner Dual AssyCOLLAR, AIR Cleaner GROMMET, AIR CleanerCollar B, AIR Cleaner GASKET, ElbowCamshaft Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Camshaft AssyHonda GX240K1PMT2/GX240U1PMT2 ENG. Camshaft Assy Carburetor Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Carburetor AssyHonda GX240K1PMT2/GX240U1PMT2 ENG. Carburetor Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Carburetor Assy SPACER, Carburetor PLATE, Lever SettingGASKET, Carburetor GASKET, InsulatorControl Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Control AssyHonda GX240K1PMT2/GX240U1PMT2 ENG. Control Assy Crankcase Cover Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Crankcase CVR. AssyHOLDER, Governor Weight WEIGHT, GovernorPIN, Governor Weight GASKET, Case CoverCrankshaft Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Crankshaft Assy90741ZE2000 Honda GX240K1PMT2/GX240U1PMT2 ENG. Crankshaft AssyCylinder Barrel Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Cylinder Barrel AssyRING, 14MM NOK NUT, Flange 10MMPIN, Lock 10MM SHAFT, Governor ARMCylinder Head Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Cylinder Head AssyHonda GX240K1PMT2/GX240U1PMT2 ENG. Cylinder Head Assy FAN Cover Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. FAN Cover AssyHonda GX240K1PMT2/GX240U1PMT2 ENG. FAN Cover Assy Flywheel Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Flywheel AssyFLYWHEEL, Complete Honda GX240K1PMT2/GX240U1PMT2 ENG. Flywheel AssyFAN, Cooling NUT, Special 16MMFuel Tank Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Fueltank AssyHonda GX240K1PMT2/GX240U1PMT2 ENG. Fueltank Assy Ignition Coil Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Ignition Coil AssyHonda GX240K1PMT2/GX240U1PMT2 ENG. Ignition Coil Assy WIRE, Stop Switch 370 MMCoil ASSY., Ignition GROMMET, CordMuffler Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Muffler Assy Piston Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Piston AssyBOLT, Connecting ROD ROD ASSY., ConnectingRing SET, Piston STD Ring SET, PistonRecoil Starter Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Recoil Starter AssyHonda GX240K1PMT2/GX240U1PMT2 ENG. Recoil Starter Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Gasket KIT Assy 061A1ZE2040 Honda GX240K1PMT2/GX240U1PMT2 ENG. Gasket KIT AssyLabels Assy Honda GX240K1PMT2/GX240U1PMT2 ENG. Labels AssyMARK, Choke Orange MARK, Throttle IndicationMARK, Choke Gray LABEL, CautionFreight Policy Terms and Conditions of Sale PartsPage Heres HOW to GET Help

qp-402h specifications

The Multiquip QP-402H is a powerful, versatile piece of construction equipment designed for a range of applications, particularly in the construction and operational sectors. Known for its durability and efficiency, the QP-402H is a part of Multiquip’s extensive portfolio of equipment that adheres to the high standards of reliability and performance.

One of the standout features of the QP-402H is its robust Honda GX160 engine, which delivers superior power and performance. The engine is designed for optimal fuel efficiency, allowing operators to maximize their productivity while minimizing operational costs. This machine is engineered to handle a wide variety of tasks, from producing high-quality concrete to powering various construction tools, making it an invaluable asset on job sites.

In terms of design, the QP-402H features a heavy-duty construction, which ensures its longevity even under strenuous working conditions. The unit is equipped with an advanced compressor system that provides consistent air supply for up to four pneumatic tools simultaneously. This multi-tool capability significantly enhances productivity on the job site, allowing crews to work more efficiently without having to wait for equipment to become available.

The QP-402H incorporates sophisticated technologies to ensure user-friendly operation. Its intuitive controls are designed to be easily accessible, enabling operators to quickly adjust settings and manage functions with minimal effort. Additionally, the compact design of the unit allows for easy transportation and maneuverability, making it a suitable choice for both large scale and tight-space projects.

Another notable characteristic of the QP-402H is its low noise level, which is increasingly important in urban environments where noise regulations are strict. This quiet operation ensures that tasks can be completed with minimal disruption, promoting better relations with surrounding communities.

Safety is a primary consideration in the design of the Multiquip QP-402H. The machine is equipped with various safety features, including a protective cage for the engine and secure fastenings for operational stability. These features contribute to a safer working environment for operators and personnel on-site.

In conclusion, the Multiquip QP-402H stands out as a reliable, efficient, and versatile solution in the realm of construction equipment. Its powerful engine, user-friendly technologies, robust construction, and safety features make it an ideal choice for professionals who require high-performance equipment that can handle varied demands in challenging environments.