Johnson Controls 22 SEER installation manual Section Xxiii Indoor and Outdoor Units Error Codes

Page 31

898841-UIM-B-0113

SECTION XXIII: INDOOR AND OUTDOOR UNITS ERROR CODES

This section identifies error codes that appear on the front panel of the indoor unit or outdoor unit control. Many of the error codes will automatically clear themselves when the error no longer exists. However some error codes may require disconnecting power to the system at the unit disconnect switch or circuit breaker in order to clear them and to resume normal system operation.

*The temperature readout (either temperature setpoint or indoor ambient) will be replaced by an error code if there is a malfunction. If multiple errors are detected, the display will alternate between each error code.

NOTE:

No history is kept on past error codes.

72

HEATINDICATOR

COOLINDICATOR

TEMPERATURE*

RUN

DEHUMIDIFY MODE

INFRARED SIGNAL RECEIVER

FIGURE 65: Indoor Unit Front Panel Indicators

GREEN LED

YELLOW LED

RED LED

FIGURE 66: Control Board

Johnson Controls Unitary Products

31

Image 31
Contents UIM-B-0113 Models 22 SeerList Section II SafetySection I General Section III Shipping and PackagingAssembled Outdoor Unit Section V Selecting Installation LocationIndoor Unit see for Installation Dimensions Remote ControlCondensate Drainage Requirement Heat Pump only Outdoor Unit see for Installation DimensionsPower Supply and INDOOR/OUTDOOR Wire Connection Section VI SpecificationsHeat Pumps Heat Pump Electrical SpecificationsMax. Fuse Size time delay a Section VII Refrigerant Line SET Requirements32.8 Max Distance Length 49.2 UIM-B-0113 Refrigerant Line Set RequirementsConnection Pipe length 24.6 24.6 Connection Pipe GasSection Viii Unit Dimensions Wall Hole Drilling Section XI Indoor Unit WiringInstalling the Wall Mounting Bracket ConnectionsBlue Section XII Pipe Forming and Drain PipingPipe Forming WhiteLeft or Left Rear Piping Right or Right Rear PipingRear or Downward Piping Flaring Work Section Xiii Flaring Work and Piping ConnectionsDrain Piping Drain Hose JunctionFt lb Section XIV Indoor Unit InstallationSection XV Outdoor Unit Installation Slab or Roof Mounting18K & 24k Section XVI Outdoor Unit Wiring ConnectionsSecuring Outdoor Unit to Slab or Frame 9K & 12K208-230V Systems 30 & 36 Kbtu Refrigerant Piping ConnectionsIndoor Unit Connection Outdoor Unit ConnectionInsulation and Taping Service ValvesLeak Test Leak Test and EvacuationAIR Purging with Vaccum Pump Adding Refrigerant for Longer Line SETSection Xviii Test Operation Section XX MaintenanceSection XIX Emergency Operation Cleaning and Maintenance Section Xxii Typical Unit Wiring Diagram18K & 24K 115V Indoor Air Conditioners 18K & 24K Indoor Air Conditioners 18K Indoor Air Conditioners 24K Indoor Air Conditioners 09K & 12K 115V Outdoor Heat Pumps 18K & 24K 115V Heat Pumps 18K & 24K Indoor Heat Pumps 18K Indoor Heat Pumps 24K Indoor Heat Pumps 30K Indoor Heat Pumps 36K Indoor Heat Pumps Johnson Controls Unitary Products Indoor Unit Front Panel Indicators Section Xxiii Indoor and Outdoor Units Error CodesError Codes 09K 12K Indoor Unit Error CodesDisplay Method of Indoor Unit UIM-B-0113 Error Codes 09K 12KDuring cooling and drying 150VAC, turn on the unit after IPM OFF 3S Indicator has 3 kinds of display Display Method of Outdoor Display Method of Indoor Unit Error Codes 18K 24KWill stop operation IPM Temperature Blink Indoor fan will operate UIM-B-0113 Error Codes 30K 36K While operation frequency Ductless Splits Technical Train Min Showing during min. cooling or On 0.25s Operation, compressor will Ductless Splits Technical Train AC175V During heating operation Wiring terminal 4V is loos York International Corp York Drive Norman, OK

22 SEER specifications

Johnson Controls has long been a leader in the heating, ventilation, and air conditioning (HVAC) industry, consistently pushing the boundaries of energy efficiency and comfort. One of their standout offerings is the 22 SEER (Seasonal Energy Efficiency Ratio) air conditioning system, which boasts advanced technologies designed to deliver optimal performance while minimizing energy consumption.

At the heart of the Johnson Controls 22 SEER system is its innovative compressor technology. The variable-speed compressor allows for precise temperature control by adjusting the cooling output according to the specific demands of your space. This means that instead of constantly turning on and off, the system can operate at lower speeds for longer periods, ensuring even cooling and reducing energy bills.

In addition to the compressor, the 22 SEER unit employs high-efficiency coils and a superior refrigeration system that work in tandem to enhance performance. These components are designed to maximize heat transfer, enabling the system to cool your home more effectively and efficiently.

Another notable feature of the Johnson Controls 22 SEER system is its smart technology integration. With a focus on convenience and energy management, these units often come equipped with Wi-Fi connectivity, allowing homeowners to control their HVAC systems remotely using a smartphone app. This capability enhances user experience by enabling real-time monitoring and scheduling, ultimately leading to smarter energy use.

The design of the units also reflects an emphasis on quiet operation. Noise reduction technologies, including sound-dampening features, ensure that the system operates quietly in the background, enhancing indoor comfort without disruptive sounds.

Durability is another standout characteristic of the Johnson Controls 22 SEER systems. These units are built with high-quality materials and rigorous testing standards, ensuring they can withstand harsh weather conditions and provide reliable performance over the years.

Moreover, the 22 SEER air conditioning systems contribute to environmental sustainability. By using less energy, they not only lower utility costs but also reduce the carbon footprint of homes, aligning with growing consumer preferences for eco-friendly solutions.

Overall, the Johnson Controls 22 SEER air conditioning system represents a significant leap forward in HVAC technology. Its blend of efficiency, innovative features, and user-friendly technologies makes it an ideal choice for environmentally-conscious homeowners seeking comfort without compromise. Whether upgrading an existing system or investing in a new one, the 22 SEER unit stands out as a prime example of luxury, efficiency, and sustainability in the HVAC market.