Johnson Controls 22 SEER installation manual Section VI Specifications

Page 5

898841-UIM-B-0113

DRAIN-WATER HOLE

BOTTOM FRAME

DRAIN PLUG

DRAIN CONNECTOR

HOSE (available commerially, inner dia. 0.63”)

FIGURE 4: Condensate Drainage

SECTION VI: SPECIFICATIONS

POWER SUPPLY AND INDOOR/OUTDOOR WIRE CONNECTION

The system should be powered from a dedicated circuit.

Wiring work should be based on applicable technical standards.

Wiring connections should be made following the provided diagrams.

Make sure all electrical connections are securely tightened.

TABLE 3: Air Conditioner Electrical Specifications

Solid conductor AWG14 or stranded conductor AWG14 are the MINI- MUM allowable wire sizes. There are some applications that will require larger gauge conductors depending on the voltage and amperage rat- ings on the data plate and the distance that the conductors will be routed. It is the installing contractor's responsibility to properly size the electrical conductors for the equipment and for the application.

All of the indoor units and outdoor units should have the electrical con- ductors sized using the National Electrical Code (NEC) and the local authority having jurisdiction whichever is more stringent. If the equip- ment is installed outside of the United States, all local codes within the country of origin must be followed.

The Ductless indoor units must have a minimum of 14 gauge, 600 volt double insulated copper conductors. The conductors for the indoor unit can be either solid or stranded copper. When possible the indoor unit should have stranded wire for the communication to ensure proper communication between the indoor and outdoor unit(s).

The Ductless outdoor units must have a minimum of 12 gauge, 600 volt double insulated copper conductors with the exception of the fol- lowing models: DHPM30CSM42Q1, DHPM36CSM42Q1, and DCPM36CSM42Q1, which require 10 gauge wire. The conductors for the outdoor unit should be solid or stranded copper conductors.

NOTICE

The listed wire sizes are only minimum requirements, as previously stated, the conductors for both indoor and outdoor units must be sized using the NEC and local authority having jurisdiction.

INDOOR UNIT

Air Conditioners

 

DCPM09NWM42Q1

DCPM09NWM41Q1

DCPM12NWM42Q1

DCPM12NWM41Q1

Power Supply (V, Phase, Hz)

208/230V/1

115V/1

208/230V/1

115V/1

Min. Circuit Ampacity

10

16

10

16

Fan Motor (F.L.A)

 

0.2

0.38

0.2

0.38

 

 

 

INDOOR UNIT

 

 

Air Conditioners

 

DCPM18NWM42Q1

DCPM24NWM42Q1

DCPM36NWM42Q1

 

Power Supply (V, Phase, Hz)

208/230V/1/60HZ

208/230V/1/60HZ

208/230V/1/60HZ

 

Min. Circuit Ampacity

16

16

17

 

Fan Motor (F.L.A)

 

0.28

0.24

0.4

 

 

 

 

OUTDOOR UNIT

 

 

Air Conditioners

 

DCPM09CSM42Q1

DCPM09CSM41Q1

DCPM12CSM42Q1

DCPM12CSM41Q1

Power Supply (V, Phase, Hz)

208/230V/1

115V/1

208/230V/1

115V/1

Max. Fuse Size (time delay) (A)

15

25

15

25

Min. Circuit Ampacity

10

16

10

16

Fan Motor (F.L.A)

 

0.14

0.17

0.14

0.17

Compressor

R.L.A

6.21

12.23

5.34

12.43

L.R.A

13.8

33

13.8

33

 

 

 

 

OUTDOOR UNIT

 

 

Air Conditioners

 

DCPM18CSM42Q1

DCPM24CSM42Q1

DCPM36CSM42Q1

 

Power Supply (V, Phase, Hz)

208/230V/1/60HZ

208/230V/1/60HZ

208/230V/1/60HZ

 

Max. Fuse Size (time delay) (A)

20

20

25

 

Min. Circuit Ampacity

16

16

17

 

Fan Motor (F.L.A)

 

0.32

1.1

0.45

 

Compressor

R.L.A

9.35

10.45

12.66

 

L.R.A

/

/

/

 

 

 

Johnson Controls Unitary Products

5

Image 5
Contents UIM-B-0113 Models 22 SeerSection I General Section II SafetySection III Shipping and Packaging ListIndoor Unit see for Installation Dimensions Section V Selecting Installation LocationRemote Control Assembled Outdoor UnitCondensate Drainage Requirement Heat Pump only Outdoor Unit see for Installation DimensionsPower Supply and INDOOR/OUTDOOR Wire Connection Section VI SpecificationsMax. Fuse Size time delay a Heat Pump Electrical SpecificationsSection VII Refrigerant Line SET Requirements Heat PumpsConnection Pipe length 24.6 UIM-B-0113 Refrigerant Line Set Requirements24.6 Connection Pipe Gas 32.8 Max Distance Length 49.2Section Viii Unit Dimensions Installing the Wall Mounting Bracket Section XI Indoor Unit WiringConnections Wall Hole DrillingPipe Forming Section XII Pipe Forming and Drain PipingWhite BlueRear or Downward Piping Right or Right Rear PipingLeft or Left Rear Piping Drain Piping Section Xiii Flaring Work and Piping ConnectionsDrain Hose Junction Flaring WorkSection XV Outdoor Unit Installation Section XIV Indoor Unit InstallationSlab or Roof Mounting Ft lbSecuring Outdoor Unit to Slab or Frame Section XVI Outdoor Unit Wiring Connections9K & 12K 18K & 24kIndoor Unit Connection Refrigerant Piping ConnectionsOutdoor Unit Connection 208-230V Systems 30 & 36 KbtuInsulation and Taping Service ValvesAIR Purging with Vaccum Pump Leak Test and EvacuationAdding Refrigerant for Longer Line SET Leak TestSection XIX Emergency Operation Section XX MaintenanceSection Xviii Test Operation Cleaning and Maintenance Section Xxii Typical Unit Wiring Diagram18K & 24K 115V Indoor Air Conditioners 18K & 24K Indoor Air Conditioners 18K Indoor Air Conditioners 24K Indoor Air Conditioners 09K & 12K 115V Outdoor Heat Pumps 18K & 24K 115V Heat Pumps 18K & 24K Indoor Heat Pumps 18K Indoor Heat Pumps 24K Indoor Heat Pumps 30K Indoor Heat Pumps 36K Indoor Heat Pumps Johnson Controls Unitary Products Indoor Unit Front Panel Indicators Section Xxiii Indoor and Outdoor Units Error CodesError Codes 09K 12K Indoor Unit Error CodesDisplay Method of Indoor Unit UIM-B-0113 Error Codes 09K 12KDuring cooling and drying 150VAC, turn on the unit after IPM OFF 3S Indicator has 3 kinds of display Display Method of Outdoor Display Method of Indoor Unit Error Codes 18K 24KWill stop operation IPM Temperature Blink Indoor fan will operate UIM-B-0113 Error Codes 30K 36K While operation frequency Ductless Splits Technical Train Min Showing during min. cooling or On 0.25s Operation, compressor will Ductless Splits Technical Train AC175V During heating operation Wiring terminal 4V is loos York International Corp York Drive Norman, OK

22 SEER specifications

Johnson Controls has long been a leader in the heating, ventilation, and air conditioning (HVAC) industry, consistently pushing the boundaries of energy efficiency and comfort. One of their standout offerings is the 22 SEER (Seasonal Energy Efficiency Ratio) air conditioning system, which boasts advanced technologies designed to deliver optimal performance while minimizing energy consumption.

At the heart of the Johnson Controls 22 SEER system is its innovative compressor technology. The variable-speed compressor allows for precise temperature control by adjusting the cooling output according to the specific demands of your space. This means that instead of constantly turning on and off, the system can operate at lower speeds for longer periods, ensuring even cooling and reducing energy bills.

In addition to the compressor, the 22 SEER unit employs high-efficiency coils and a superior refrigeration system that work in tandem to enhance performance. These components are designed to maximize heat transfer, enabling the system to cool your home more effectively and efficiently.

Another notable feature of the Johnson Controls 22 SEER system is its smart technology integration. With a focus on convenience and energy management, these units often come equipped with Wi-Fi connectivity, allowing homeowners to control their HVAC systems remotely using a smartphone app. This capability enhances user experience by enabling real-time monitoring and scheduling, ultimately leading to smarter energy use.

The design of the units also reflects an emphasis on quiet operation. Noise reduction technologies, including sound-dampening features, ensure that the system operates quietly in the background, enhancing indoor comfort without disruptive sounds.

Durability is another standout characteristic of the Johnson Controls 22 SEER systems. These units are built with high-quality materials and rigorous testing standards, ensuring they can withstand harsh weather conditions and provide reliable performance over the years.

Moreover, the 22 SEER air conditioning systems contribute to environmental sustainability. By using less energy, they not only lower utility costs but also reduce the carbon footprint of homes, aligning with growing consumer preferences for eco-friendly solutions.

Overall, the Johnson Controls 22 SEER air conditioning system represents a significant leap forward in HVAC technology. Its blend of efficiency, innovative features, and user-friendly technologies makes it an ideal choice for environmentally-conscious homeowners seeking comfort without compromise. Whether upgrading an existing system or investing in a new one, the 22 SEER unit stands out as a prime example of luxury, efficiency, and sustainability in the HVAC market.