Check the electrical supply to be sure that it meets the values specified on the unit nameplate and wiring label.

Power wiring, control (low voltage) wiring, disconnect switches and over current protection must be supplied by the installer. Wire size should be sized per NEC requirements.

All field wiring must USE COPPER CONDUCTORS ONLY and be in accordance with Local, National, Fire, Safety & Electrical Codes. This unit must be grounded with a separate ground wire in accor- dance with the above codes.

The complete connection diagram and schematic wiring label is located on the inside surface of the unit service access panel.

FIELD CONNECTIONS POWER WIRING

1.Install the proper size weatherproof disconnect switch outdoors and within sight of the unit.

2.Remove the screws at the top and sides of the corner cover. Slide corner cover down and remove from unit.

3.Run power wiring from the disconnect switch to the unit.

4.Route wires from disconnect through power wiring opening pro- vided and into the unit control box as shown in Figure 6.

5.Install the proper size time-delay fuses or circuit breaker, and make the power supply connections.

CONTACTOR

GROUND

LUG

LOW

VOLTAGE

BOX

REVERSIBLE HIGH

 

“FINGERED”

DUAL

BUSHING

VOLTAGE CONDUIT PLATE

RUN/FAN

 

 

 

 

CAPACITOR

 

FIGURE 7: Outdoor Unit Control Box

FIELD CONNECTIONS CONTROL WIRING

1.Route low voltage wiring into bottom of control box as shown in Figure 6. Make low voltage wiring connections inside the low volt- age box per Figures 7-9.

2.The complete connection diagram and schematic wiring label is located on the inside surface of the unit service access panel.

3.Replace the corner cover removed in Step 2.

4.All field wiring to be in accordance with national electrical codes (NEC) and/or local-city codes.

NOTE: A Start Assist Kit is available and recommended for long line set applications or in areas of known low voltage problems.

5.Mount the thermostat about 5 ft. above the floor, where it will be exposed to normal room air circulation. Do not place it on an out- side wall or where it is exposed to the radiant effect from exposed glass or appliances, drafts from outside doors or supply air grilles.

6.Route the 24-volt control wiring (NEC Class 2) from the outdoor unit to the indoor unit and thermostat.

NOTE: To eliminate erratic operation, seal the hole in the wall at the thermostat with permagum or equivalent to prevent air drafts affecting the operation of in the thermostat.

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-1-60

24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2)

POWER WIRING

CONTROL WIRING

FACTORY WIRING

FURNACE OR AIR HANDLER TERMINAL BLOCK

GND.

LUG

CONTACTOR TERMINALS

COIL

*TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.

C Y R G W

Y R G W

*

CONDENSING UNIT

ROOM THERMOSTAT

 

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

FIGURE 8: Typical Field Wiring (Air Handler / Electrical Heat)

6

Johnson Controls Unitary Products

Image 6
Contents List of Figures Section II SafetyList of Sections List of TablesSection III Unit Installation Precautions During Brazing Service Valve Precautions During Line InstallationPrecautions During Brazing of Lines Piping ConnectionsSection IV Orifice Installation Tions During Brazing Service ValveSection VII System Charge Section V Installations Requiring AN ADD-ON TXV KITSection VI Evacuation Subcooling Charging Method Mixed Match CoilsSection Viii Electrical Connections Field Connections Power WiringField Connections Control Wiring General Information & GroundingThermostat PSC Single Stage AC 1AID Models AIR Handler AIR ConditionerAIR AC 1BThermostat AIR Handler ConditionerAC 5D PSC AIR Furnace ConditionerAC 5E PSC AIRFurnace Conditioner Indications of Proper Operation CoolingJohnson Controls Unitary Products York Drive Norman, OK

13 SEER specifications

Johnson Controls has long been a leader in the HVAC industry, renowned for its commitment to energy efficiency and innovative technology. One of its prominent offerings is the 13 SEER air conditioning unit, which stands for Seasonal Energy Efficiency Ratio. This rating signifies a balance between initial cost and ongoing energy savings, making it an ideal choice for a range of residential and commercial applications.

The 13 SEER unit boasts several key features that set it apart from other air conditioning systems. Firstly, its robust design incorporates high-quality materials, ensuring durability and longevity. This unit is built to withstand various environmental conditions, making it a reliable option for any climate.

One of the standout technologies within the 13 SEER unit is its advanced scroll compressor. This component increases efficiency by minimizing energy consumption while maximizing cooling output. By operating quietly and smoothly, the scroll compressor contributes to a more comfortable indoor environment without the disruptive sounds often associated with traditional AC units.

Additionally, Johnson Controls has equipped the 13 SEER system with environmentally friendly refrigerants, aligning with modern standards for sustainability and reduced environmental impact. This eco-conscious approach ensures that the unit not only performs efficiently but also meets regulatory guidelines for emissions.

Ease of installation and maintenance is another significant advantage. The 13 SEER system is designed with user-friendliness in mind, allowing for straightforward setup, which can save on initial installation costs. Maintenance practices have also been simplified, with features such as easy access panels and diagnostic capabilities that help technicians identify and resolve issues quickly.

In terms of characteristics, the 13 SEER unit often comes equipped with a range of customizable options, including variable speed blower fans and smart connectivity features. These enhancements allow homeowners to optimize their cooling experience based on their individual preferences, promoting energy savings while ensuring comfort during the warmer months.

Overall, Johnson Controls' 13 SEER air conditioning unit provides an exceptional blend of efficiency, reliability, and innovative technology. With its eco-friendly refrigerants, advanced scroll compressor, and commitment to user-friendly design, this unit offers an optimal cooling solution for those seeking energy-efficient options in today’s environmentally conscious landscape. Whether for residential or commercial use, the 13 SEER air conditioning unit stands as a testament to Johnson Controls' dedication to excellence in the HVAC market.