2.2Maximum Developed Boost Pressure

SS

Series

Table 2.2

Maximum Developed

Boost Pressure

Maximum Developed

 

Number of Centrifugal

Pressure

 

 

Stages

psig (barg)

 

 

 

 

 

 

 

 

 

50 Hertz

60 Hertz

 

50 Hertz

60 Hertz

500

630 (43.4)

700 (48.3)

76

58

1000

300 (20.7)

340 (23.4)

N/A

28

1800

570 (39.3)

680 (46.9)

56

48

2.3Maximum Recommended Operating Temperature

The maximum recommended operating temperature range is 125°F (52°C). The max- imum operating temperature is dependent upon the operating pressure. For high temperature applications, consult the factory for special materials of construction.

The maximum recommended temperature is stated on the pump case. The temper- ature stated is for the design flow and pressure.

2.4Standard Materials of Construction

SS:Wetted castings and pump shaft are 316 stainless steel (SS). The pump casing is 316SS. Impellers and diffusers are Noryl. The mechanical seal has a carbon rotating face and a ceramic stationary face. The secondary sealing element of the mechanical seal is Buna-N. The O-rings and diffuser bearings are Buna-N.

2.5Special Materials of Construction

Optional ethylene propylene (EPDM), Viton*, and Teflon* elastomers are available. Contact the factory.

*Viton and Teflon are trademarks of E.I. DuPont de Nemours and Company, Inc.

3

Image 9
Contents Osmonics TONKAFLO Pumps SS Series Page Introduction Tonkaflo Specifications Cutaway Drawings List of Figures Page Introduction Tonkaflo Specifications Capacities 2900 rpm 3500 rpm Maximum500 Hertz D e l S S 1 8 4 8 X B 5 D e l S S 5 0 5Inlet and Discharge Piping and Connections Inlet Piping Pump InstallationInlet Piping Page Primed Before START-UP Installation Discharge ScreenSteps Motor Wiring Single-Phase MotorsChanging Motor Rotation Rolling the Leads to Balance Current Draw LOW Flow Motor Runs HOT or Stops General Troubleshooting for ALL PumpsSteps Page Page Force the Shaft Into the Impeller Bore Tonkaflo Pump Field Maintenance Motor Installation XB and XC Motor Adapter Pumps Steps Page Liquid END Tonkaflo Service Policy Tonkaflo Pump Return Goods Authorization RGA Procedure 500X Motor Adapter Pump Dimensional DrawingsXB Motor Adapter Pump 1000X Motor Adapter Pump 1800XB Motor Adapter Pump 1800XC Motor Adapter Pump Cutaway Drawings XB and XC Motor Adapter Pump Description Standard Model Parts ListPart Number Series Ordering Parts Warranty Tonkaflo Pump Warranty Page USA France Thailand
Related manuals
Manual 42 pages 10.61 Kb

SS500, SS1800, SS1000 specifications

The GE SS1000, SS1800, and SS500 are advanced gas turbine models developed by General Electric, renowned for their efficiency, reliability, and adaptability in various applications. These turbines are integral to numerous power generation systems across the globe, catering to both industrial and utility sectors.

The GE SS1000 is one of the earlier models in this series, notable for its compact design and robust performance. Engineered for effective operation in both simple cycle and combined cycle power plants, the SS1000 offers a remarkable power output that can be tailored to meet the specific needs of the user. It features advanced materials and a sophisticated cooling system, which enhance its efficiency and longevity. Additionally, the SS1000's design focuses on ease of maintenance, allowing for quick inspections and component replacements, which minimizes downtime and operational costs.

Moving up the scale, the GE SS1800 provides enhanced performance capabilities, making it suitable for larger power demands. One of its significant characteristics is its high thermal efficiency, which is achieved through improved combustion technology and aerodynamic design. The SS1800 also integrates advanced digital controls that optimize its operation, resulting in superior load flexibility. This adaptability is crucial for power plants that need to respond swiftly to fluctuations in demand. Furthermore, the turbine features a modular design, allowing for easier upgrades and maintenance.

The GE SS500 represents a further evolution in gas turbine technology, characterized by its high output and fuel efficiency. This model utilizes advanced ceramic matrix composites, which enable higher operating temperatures without compromising performance. The SS500 is engineered for both gas and dual-fuel configurations, providing operational flexibility that is essential in today's energy landscape. Its advanced diagnostics and predictive maintenance capabilities help operators monitor performance and identify potential issues before they escalate, ensuring continuous and reliable power generation.

In summary, the GE SS1000, SS1800, and SS500 turbines are milestones in gas turbine technology. Each model offers unique features that cater to various power generation needs, with a strong emphasis on efficiency, adaptability, and reliability. As the energy sector continues to evolve, these turbines represent a pivotal innovation that ensures a sustainable and efficient energy future.