GE 2900, 3900 Installing the Zoneline, Install the Wall Case Exterior Grille, Prepare the Unit

Page 17

Installation Instructions

INSTALLING THE ZONELINE

1INSTALL THE WALL CASE AND

EXTERIOR GRILLE

The RAB71 series or RAB77 wall case must be properly installed per instructions packed with the case.

Remove the corrugated stiffener and the outdoor protective panel. Use the slit in the outdoor panel as a handhold and push out.

Protective

 

 

 

Slit

 

 

panel

 

 

 

 

Stiffener

Install the exterior grille from the room side following instructions packed with the grille.

Insulated Wall Case

This unit is designed to be installed in a GE plastic or an insulated steel wall case. This minimizes condensation from forming on the room side of the case.

The RAB71 series wall cases are insulated. Insulation kit RAK901L is available for use with RAB77 or existing uninsulated wall cases when needed.

NOTE: For installation with a subbase or duct adapter, see the instructions packed with those kits.

2PREPARE THE UNIT

Carefully remove shipping tape and foam shipping blocks from the room cabinet, compressor and vent door. There may be multiple blocks and pieces of shipping tape that need to be removed.

Shipping tape (Locations may vary)

Remove the room cabinet by pulling it out at the bottom to release it (1), then lift it up to clear the rail along the unit top (2).

If vent door is to be operational, remove shipping screws from the front side of the vent door, if present.

Remove two shipping screws

17

Image 17
Contents Write the model and serial numbers here Model # Serial # Air ConditionersConsumer Support Care and CleaningReplacing an existing unit? Fan, Mode & Operation Control Safety InstructionsQuick Heat Recovery Care and Cleaning Troubleshooting TipsCare and Cleaning To Remove the Room Cabinet Other features of your ZonelineTroubleshooting Tips Consumer Support Air Direction Ventilation ControlAuxiliary Controls on your Zoneline Load Shedding Central Desk Control Temperature LimitingFreeze Sentinel Constant on FanGe.com Heat SentinelCentral Desk Control External Fan Obtained locallyCare and cleaning Instructions Safety Operating InstructionsTroubleshooting Tips Consumer Support Air Filters Zoneline Components Before YOU BeginTools YOU will Need Use the correct wall case Replacing AN Existing UNIT?Power Cord Connection 230/208 Volt Electrical Connection Options HOW to ConnectPower Direct Connection For Direct Connect Installation For Subbase Installation Branch Circuit Proper GE Power Branch Circuit PowerMake Electrical Connection to the Unit Power Cord Connections Power Connection ChartPrepare the Unit Installing the ZonelineInstall the Wall Case Exterior Grille Replace the Room Cabinet Install the Unit Into the Wall CaseExternal Drain OPTIONAL-DRAIN KIT InstallationZoneline does Before you call for service…Not start Or heat as it shouldAir is not always Temperature displayCool or hot during OperationNormal Operating Sounds Things that are normalCleaning Zoneline WarrantyGE Will Replace One YearParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio