Samsung ACC2800C, UCC2800C, UCC2400C, ACC2400C installation manual Drain Hose Installation, Unit

Page 42

Drain Hose Installation

Drain tube outlet

 

Insulation drain sub

Indoor

Band(Not supplied)

Unit

 

Adhesives

Insulation drain pipe

Insulation cover drain

CAUTION

Must fit tightly against body without any gap.

No gap

Care must be taken when installing the drain hose for the indoor unit to ensure that any condensate water is correctly drained outside.

1Insert the flexible hose to the drain tube outlet, if necessary.

Note Attach the drain hose to the drain tube outlet with the adhesives to prevent water leaks, then secure the hose with a band etc..(The band is not supplied with the air conditioner.)

2Install the drain hose so that its length can be as short as possible. Internal diameter of the drain hose should be the same or slightly bigger than the external diameter.

Inner diameter of the drain hose

Flexible hose is connected

Flexible hose is not connected

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

32mm/1

inch(Outer diameter)

 

 

27mm/1inch(Outer diameter)

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note Give a slightly slant to the drain hose for proper drainage of condensate.

Secure the drain hose with the band joint and the cable-tie not to be separated from the unit.

3Wrap the drain hose with the insulation drain as shown in figure and secure it.

Note When connecting the drain hose without the flexible hose, you should attach it to the drain tube outlet with adhesives and tapes to prevent water leaks.

CAUTION

Check that the indoor unit is level with the ceiling by using the leveler.

Do not install air bleeding tubes, as this may cause water to spray from the drain tube outlet.

If it is necessary to increase the height of the drain hose somewhat, the portion directly after 30cm/1ft. If it is raised higher than 50cm/1 85 ft , there can be water leaks.

Air bleeder

300mm(12")or less

1~1.5m (3~5ft)

 

 

 

 

 

 

Band joint

Flexible hose

Ceiling

Ceiling

55 200mm( 8 ft) 550mm(18 ft) or less

ft) or less

 

7

16

 

(2

 

 

750mm

 

 

 

 

 

 

 

 

 

Do not give the hose and upward gradient after the connection port.

This will cause water to flow backwards when the unit is stopped, resulting in water leaks.

Upward gradient

Do not apply force to the piping on the unit side when connecting the drain hose. The hose should not be allowed to hang loose from its connection to the unit. Fasten the hose to a wall, frame or other support as close to the unit as possible.

Support pieces

1~1.5m(3~5ft)

1/100 or more

Ceiling

Ceiling

E-42

Image 42
Contents Manuel D’UTILISATION & Manuel D’INSTALLATION Safety Precautions Contents View of the Unit Outdoor Unit Wired Remote Controller-Buttons and Display Wireless Remote Controller-Buttons and Display Wireless remote controller is an optional accessoryCentralized Controller Indicators on the Unit For Wireless Remote Controller Only Getting Start Inserting the Wireless Remote Controller Batteries Using Wired Remote Controller Selecting the Automatic Operating Mode Cooling Your Room Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Setting the On Timer To Cancel the On TimerSetting the Off Timer To Cancel the Off TimerUsing Wireless Remote Controller Selecting the Automatic Operation Mode Cooling Your Room Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Setting the On Timer Setting the Off Timer Using the Centralized Controller Temperature and Humidity Ranges Operating RecommendationsCleaning Your Air Conditioner Bio-Pure Filter Installation Optional Solving Common Problems Wired Remote ControllerSpecifications ModelInstallation Manual Indoor Unit DimensionsPurging the Unit Deciding on Where to Install the Air Conditioner Indoor UnitSpace requirement when installing the indoor unit Air Conditioner and Accessories Basic AccessoriesIndoor Unit Installation Connecting the Connection Cord Purging the UnitWiring Diagram SUB PCBDrain Hose Installation UnitTesting the drainage Connecting the Indoor Unit Assembly Piping There are two refrigerant pipes of differing diametersCutting/Flaring the Pipes Depth aConnecting the Cables to the Outdoor Unit Two electric cables must be connected to the outdoor unitChecking Correct Grounding Fixing the Unit in Position Connecting Up and Removing Air In the Circuit Adding RefrigerantPerforming Leak Tests Insulation Installing the Front Panel Setting Up Option Switches Main PCB in the Indoor UnitPCB in the Wired Remote Controller Sub PCB in the Indoor UnitCentralized Controller TransmitterOriginal Position of Option Switches Option Place Component No State Main PCBWired Remote Controller Installation Optional AccessoriesCentralized Controller Installation Optional Cable type Double-insulation 2GShield Cable Receiver & Display Unit Installation Optional Bio-Pure Filter Installation Optional With Wired Remote Controller Controlling a GroupWith Centralized Controller Checking and Testing Operations Wired Remote ControllerWireless Remote Controller Troubleshooting Meaning of Error CodeReceiver & Display Unit Explaining Operations to the Owner Memo Electronics

ACC2400C, ACC2800C, UCC2400C, UCC2800C specifications

Samsung has consistently been at the forefront of innovation in the electronics industry, and its ACC and UCC series of air conditioners—namely the ACC2800C, ACC2400C, UCC2400C, and UCC2800C—stand as a testament to this commitment. These models are designed to provide exceptional comfort and efficiency for both residential and commercial applications.

The ACC2800C and ACC2400C models are known for their powerful cooling capabilities. The ACC2800C features a robust performance with a cooling capacity of up to 28,000 BTUs, making it ideal for larger spaces. In contrast, the ACC2400C, with a cooling capacity of 24,000 BTUs, is tailored for medium-sized rooms, striking a balance between power and efficiency.

In terms of technology, both models incorporate advanced inverter technology which allows for more precise temperature control, optimizing energy consumption. This means that users can enjoy a cooler environment without worrying about soaring energy bills. Additionally, the units are equipped with an intelligent air flow system that ensures even distribution of cool air throughout the space, enhancing comfort levels across the board.

On the other hand, the UCC2400C and UCC2800C models are recognized for their unique features tailored towards enhancing user convenience. These units come with a state-of-the-art smart control system, which can be managed via smartphones—allowing users to adjust temperatures and settings remotely. This feature is particularly beneficial for those who want to prepare their spaces in advance before arriving home.

The UCC series also includes air purification technology, which helps eliminate allergens and pollutants, promoting a healthier indoor environment. Furthermore, the addition of a self-cleaning function in both models helps maintain optimal performance and efficiency.

Key characteristics of these air conditioner models include whisper-quiet operation, ensuring indoor comfort isn’t disrupted by loud machinery. This is particularly advantageous during night-time use. Moreover, the sleek and modern design of the units allows them to blend seamlessly into any decor, appearing as a stylish addition rather than an eyesore.

Overall, the Samsung ACC2800C, ACC2400C, UCC2400C, and UCC2800C represent a convergence of efficiency, technology, and comfort. With their powerful cooling capabilities, advanced features, and user-oriented designs, they cater to a wide range of needs, ensuring that consumers can enjoy a comfortable environment throughout the year.