GE 49-7400, ASP08 Through the Wall Installation Instructions-Optional, Finish the Wall Opening

Page 15

Through the Wall Installation Instructions–Optional.

The case may be installed through the wall in both existing and new construction.

Read completely, then follow step-by-step.

Safety

1 IMPORTANT

Through the wall installation is not appropriate if any of the side louvers in the case will be obstructed by the wall.

All side louvers in the case must project on the outdoor side of the wall.

The room side of the case must project into the room at least 134from the finished wall.

The case must be installed level from side-to-side and with a slight tilt from front to rear. Use a level; about a 1/2 bubble will be the correct case slant to the outside.

ARemove the air conditioner from the case. For specific instruction, refer to the Window Installation Instructions.

BMake certain a wall receptacle is available close to the hole location or make arrangements to install a receptacle.

CPlace the case in the wall opening and secure with 12 1″ long #10 wood screws.

NOTE: Drill pilot holes, if necessary, for proper installation. If the frame is oversized, use shims to prevent case distortion.

Instructions Operating Instructions Installation

2

Finish the Wall Opening

Caulk all four sides on the outdoor side of the case to prevent moisture from getting through to the

interior wall. Use of flashing (drip rail) will further prevent water from dripping inside the wall and

down the outside of the building.

 

Instructions

Lintel angle (if required)

Caulking

OUTSIDE

Air louvers (must project on the outdoor side of the wall.)

Wood Filler and Caulking

(above & below the flashing)

Flashing (Drip rail)

Plaster line

Trim molding (if desired)

INSIDE

Bottom rail

4.5 cm (13/4) min.

Troubleshooting Tips Consumer Support

15

Image 15
Contents Write the model and serial numbers here 49-7400 10-00 JRInstructions Operating Instructions Safety PrecautionsOperating Installation InstructionsConsumer Support Troubleshooting TipsInstallation Instructions Remote ControlAir Direction Up and Down Cool ModeFAN Mode Vent ControlInstallation InstructionsConsumer Support Air Direction Side-to-Side SafetyInstructions Troubleshooting Tips Consumer SupportOutdoor Coils Care and cleaning of the air conditionerHow to Insert the Batteries Grille and CasePreparing to install the air conditioner Operating InstructionsRead these instructions completely and carefully Window Installation Instructions Safety Instructions Operating Window RequirementsStorm Window Requirements Operating Instructions Safety Instructions Remove the Air Conditioner From the CasePrepare the Case Troubleshooting Tips Consumer Support Install the Case in the WindowInstall the Security Bracket and the Foam Top Window Gasket Install the Air Conditioner in the Case Operating Instructions SafetyThrough the Wall Installation Instructions-Optional Instructions Operating Instructions InstallationFinish the Wall Opening Before you call for service… Consumer SupportNormal Operating Sounds We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration For The Period Air Conditioner WarrantyWhat Is Not Covered We Will ReplaceReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website

49-7400, AST08, ASP10, ASP08 specifications

The GE AST08, ASP08, 49-7400, and ASP10 are representative models in the portfolio of General Electric's advanced industrial hardware and software solutions. Each of these products is designed to enhance operational efficiency, optimize performance, and integrate seamlessly into existing systems.

The GE AST08, known for its robust performance in automation and control applications, features advanced processing capabilities and increased connectivity options. It supports multiple communication protocols, ensuring compatibility with a wide range of industrial systems. The AST08 is built to withstand harsh industrial environments, with a durable design that includes temperature and vibration resistance, making it an essential tool for reliability in manufacturing operations.

Similarly, the ASP08 model is equipped with enhanced data processing capabilities, making it efficient for real-time applications. With its powerful CPU and expanded memory options, the ASP08 is particularly suited for tasks that require quick data analysis and decision-making. This model also includes built-in cybersecurity features to safeguard sensitive information, addressing the growing concerns over data breaches in industrial settings.

The 49-7400, on the other hand, is designed for scalability and flexibility. It can adapt to rapidly changing industrial needs and is compatible with a variety of input and output configurations, allowing users to customize their setups according to specific project requirements. This flexibility makes the 49-7400 an ideal choice for enterprises looking to implement IoT solutions and smart manufacturing practices.

Finally, the ASP10 enhances user experience through its intuitive interface and sophisticated software capabilities. The ASP10 model is designed for seamless integration with cloud services, utilizing big data analytics to provide insights into operational efficiency and predictive maintenance. This empowers businesses to make data-driven decisions and significantly reduce downtime.

In conclusion, these models from GE offer a blend of advanced technologies, robust design, and enhanced connectivity options. With a focus on real-time processing, scalability, and cybersecurity, the AST08, ASP08, 49-7400, and ASP10 represent significant advancements in industrial hardware, helping organizations streamline operations and innovate within their sectors.