GE ASD06* operating instructions Before you call for service…

Page 13

Before you call for service…

ge.com

Troubleshooting Tips

Save time and money! Review the chart below first and you may not need to call for service.

Problem

 

Possible Causes

What To Do

 

 

 

 

Air conditioner

 

The air conditioner

Make sure the air conditioner plug is pushed completely

does not start

 

is unplugged

into the outlet.

 

 

 

 

 

 

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

 

 

breaker is tripped

the fuse or reset the breaker.

 

 

 

 

 

 

Power failure

The unit will automatically re-start in the settings last

 

 

 

used after the power is restored.

 

 

 

There is a protective time delay (approximately

 

 

 

3 minutes) to prevent tripping of the compressor

 

 

 

overload. For this reason, the unit may not start

 

 

 

normal cooling or heating for 3 minutes after it

 

 

 

is turned back on.

 

 

 

 

 

 

The current interrupter

Press the RESET button located on the power cord plug.

 

 

device is tripped

If the RESET button will not stay engaged, discontinue

 

 

 

use of the air conditioner and contact a qualified service

 

 

 

technician.

 

 

 

 

Air conditioner

 

Ice blocks the air flow

Set the mode control at FAN or HIGH COOL with the

freezing up

 

and stops the air conditioner

temp control at a warmer setting.

 

 

from cooling the room

 

 

 

 

 

Air conditioner does not

 

Airflow is restricted

Make sure there are no curtains, blinds or furniture

cool as it should

 

 

blocking the front of the air conditioner.

 

 

 

 

 

 

The temp control may

Turn the temperature knob clockwise as far as possible.

 

 

not be set correctly

 

 

 

 

 

 

 

The air filter is dirty

Clean the filter at least every 30 days. See the Operating

 

 

 

Instructions section.

 

 

 

 

 

 

The room may have been hot

When the air conditioner is first turned on you need

 

 

 

to allow time for the room to cool down.

 

 

 

 

 

 

Cold air is escaping

Check for open furnace floor registers and

 

 

 

cold air returns.

 

 

 

Set the air conditioner’s vent to the closed position.

 

 

 

 

 

 

Cooling coils have iced up

See “Air conditioner freezing up” below.

 

 

 

 

Air conditioner does not

 

Airflow is restricted

Make sure there are no curtains, blinds or furniture

warm as it should

 

 

blocking the front of the air conditioner.

 

 

 

 

 

 

The temp control may

Turn the knob counterclockwise as far as possible.

 

 

not be set low enough

The lowest setting provides maximum warming.

 

 

 

 

 

 

The air filter is dirty

Clean the filter at least every 30 days. See the Operating

 

 

 

Instructions section.

 

 

 

 

 

 

The room may have been cold

When the air conditioner is first turned on, you need to

 

 

 

allow time for the room to warm up.

 

 

 

 

 

 

Warm air is escaping

Check for open furnace floor registers and

 

 

 

cold air returns.

 

 

 

 

13

Safety Instructions Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support

Image 13
Contents Write the model and serial numbers here Model # Serial # Ge.comSafety Precautions Ge.com USE of Extension CORDS-115-Volt models onlyAbout the controls on the air conditioner Mode ControlTemp Control Cooling DescriptionsAir Direction-Side-to-Side Vent ControlAir Direction-Up and Down Water Drain ValveGrille and Case Care and cleaning of the air conditionerOutdoor Coils Air FilterElectrical Requirements Before YOU BeginTools YOU will Need Parts Included Installation InstructionsStorm Window Requirements Window RequirementsPrepare the Window and the Case Remove the AIR Conditioner from the CasePrepare the Window Install the Case in the WindowInstall the AIR Conditioner in the Case Install a Support Bracket and the Foam TOP Window GasketBefore you call for service… Water drips indoors Water drips outsideWater collects Base panNormal Operating Sounds SafetyConsumer Support We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration What Is Not Covered GE Air Conditioner WarrantyGE Will Replace Parts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio

ASD06* specifications

The GE ASD06* is a highly regarded air-cooled, scroll compressor that exemplifies advanced engineering and efficiency in HVAC applications. Known for its compact design and reliability, this model finds extensive use in both commercial and residential settings.

One of the key features of the GE ASD06* is its innovative scroll technology. Unlike traditional reciprocating compressors, the scroll design offers smoother operation with fewer moving parts, leading to enhanced durability and reduced maintenance costs. This technology allows for quiet performance, making it an excellent choice for applications where noise reduction is a priority.

Efficiency is another hallmark of the GE ASD06*. The compressor is designed to meet or exceed energy efficiency standards, contributing to lower energy consumption and reduced operating costs for users. Its high SEER (Seasonal Energy Efficiency Ratio) rating positions it as an environmentally friendly choice, promoting sustainable cooling solutions without sacrificing performance.

The GE ASD06* also incorporates smart control capabilities. This feature allows for precise monitoring and modulation of the compressor’s operation, ensuring optimal performance under varying load conditions. Users can benefit from enhanced comfort levels, as the system can adapt to changes in outdoor temperatures and indoor demand seamlessly.

In terms of installation, the GE ASD06* is designed to be versatile and straightforward. Its compact design allows for easy integration into a variety of setups, and it can be installed in confined spaces where traditional models may not fit. The unit is also equipped with a robust refrigerant system, compatible with modern environmentally-friendly refrigerants, further emphasizing its commitment to sustainability.

Safety features are integrated into the design of the GE ASD06*, including built-in thermal overload protection, which prevents damage from excessive heat and ensures long-term reliability. Additionally, its corrosion-resistant construction extends the lifespan of the unit, providing users with peace of mind regarding their investment.

In summary, the GE ASD06* stands out for its advanced scroll technology, energy efficiency, smart control capabilities, and ease of installation. With its durable design and user-friendly features, it serves as an excellent choice for those seeking a reliable and efficient air conditioning solution. It represents GE’s commitment to innovation in the HVAC industry, delivering exceptional performance while prioritizing sustainability and environmental responsibility.