IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

SAFETY PRECAUTIONS

Instructions Operating Instructions

Use this appliance only for its intended purpose as described in this Owner’s Manual.

This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.

Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.

Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

Turn the unit OFF and unplug your air conditioner before making any repairs or cleaning.

NOTE: We strongly recommend that any servicing be performed by a qualified individual.

For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

Installation

HOW TO CONNECT ELECTRICITY

Consumer Support Troubleshooting Tips

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified

service technician.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered,

it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

2

Image 2
Contents Ge.com Write the model and serial numbers here Model # Serial #Safety Precautions USE of Extension CORDS-115-Volt models only Ge.comTemp Control Mode ControlAbout the controls on the air conditioner Cooling DescriptionsAir Direction-Up and Down Vent ControlAir Direction-Side-to-Side Water Drain ValveOutdoor Coils Care and cleaning of the air conditionerGrille and Case Air FilterTools YOU will Need Before YOU BeginElectrical Requirements Installation Instructions Parts IncludedWindow Requirements Storm Window RequirementsRemove the AIR Conditioner from the Case Prepare the Window and the CaseInstall the Case in the Window Prepare the WindowInstall a Support Bracket and the Foam TOP Window Gasket Install the AIR Conditioner in the CaseBefore you call for service… Water collects Water drips outsideWater drips indoors Base panSafety Normal Operating SoundsConsumer Support We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration GE Will Replace GE Air Conditioner WarrantyWhat Is Not Covered Consumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio

ASD06* specifications

The GE ASD06* is a highly regarded air-cooled, scroll compressor that exemplifies advanced engineering and efficiency in HVAC applications. Known for its compact design and reliability, this model finds extensive use in both commercial and residential settings.

One of the key features of the GE ASD06* is its innovative scroll technology. Unlike traditional reciprocating compressors, the scroll design offers smoother operation with fewer moving parts, leading to enhanced durability and reduced maintenance costs. This technology allows for quiet performance, making it an excellent choice for applications where noise reduction is a priority.

Efficiency is another hallmark of the GE ASD06*. The compressor is designed to meet or exceed energy efficiency standards, contributing to lower energy consumption and reduced operating costs for users. Its high SEER (Seasonal Energy Efficiency Ratio) rating positions it as an environmentally friendly choice, promoting sustainable cooling solutions without sacrificing performance.

The GE ASD06* also incorporates smart control capabilities. This feature allows for precise monitoring and modulation of the compressor’s operation, ensuring optimal performance under varying load conditions. Users can benefit from enhanced comfort levels, as the system can adapt to changes in outdoor temperatures and indoor demand seamlessly.

In terms of installation, the GE ASD06* is designed to be versatile and straightforward. Its compact design allows for easy integration into a variety of setups, and it can be installed in confined spaces where traditional models may not fit. The unit is also equipped with a robust refrigerant system, compatible with modern environmentally-friendly refrigerants, further emphasizing its commitment to sustainability.

Safety features are integrated into the design of the GE ASD06*, including built-in thermal overload protection, which prevents damage from excessive heat and ensures long-term reliability. Additionally, its corrosion-resistant construction extends the lifespan of the unit, providing users with peace of mind regarding their investment.

In summary, the GE ASD06* stands out for its advanced scroll technology, energy efficiency, smart control capabilities, and ease of installation. With its durable design and user-friendly features, it serves as an excellent choice for those seeking a reliable and efficient air conditioning solution. It represents GE’s commitment to innovation in the HVAC industry, delivering exceptional performance while prioritizing sustainability and environmental responsibility.