GE AG_12 12, AG_08 8, AG_10 10, AG_07 7, 000 BTU models owner manual Storm Window Requirements

Page 10

Window Installation Instructions

Read completely, then follow step-by-step.

1

Window Requirements

These instructions are for a standard double-

hung window. You will need to modify them for

other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions below.

7,000 and 8,000 BTU models

14min.

22to 36

(With accordion panels)

1834min.

(Without accordion panels)

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

10,000 and 12,000 BTU models

16min.

27to 39

(With accordion panels)

2378min.

(Without accordion panels)

TroubleshootingTips Installation Instructions OperatingInstructions SafetyInstructions

CustomerService

2

Storm Window Requirements

A storm window frame will not allow the air

conditioner to tilt towards the outside and will keep

 

it from draining properly. To adjust for this, attach

 

a piece of wood to the stool.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2higher

 

 

 

 

 

 

 

 

 

 

 

 

 

 

than frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storm window

 

 

 

 

 

frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WOOD PIECES—

WIDTH: 2″

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

10

Image 10
Contents 3828A30036Q Pub. No -7390 JRGE & You, a Service Partnership Two easy ways to register your applianceSafety Precautions Read and follow this Safety Information carefully USE of Adapter Plugs -115-Volt models onlyControls Mode ControlsAbout the controls on the air conditioner Temp ControlsAir Direction Side-to-Side Vent ControlAir Direction Up and Down Outdoor Coils Care and cleaning of the air conditionerGrille and Case Air FilterElectrical Requirements Preparing to install the air conditionerBefore You Begin Tools You Will NeedWindow Installation Instructions Parts IncludedWindow Requirements Storm Window RequirementsPrepare the Window and the Case Remove the Air Conditioner From the CaseInstall the Case in the Window Mounting railInstall the Air Conditioner in the Case Before you call for service… Normal Operating SoundsSafety Instructions CustomerService We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration What GE Will Not Cover Air Conditioner WarrantyGE Will Replace For The PeriodService Telephone Numbers