GE AGH06, AGW06 operating instructions Storm Window Requirements, Prepare the Window

Page 11

Installation Instructions

1WINDOW REQUIREMENTS

These instructions are for a standard double-hung window. You will need to modify them for other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

13″ min.

22″ to 36

(With accordion panels)

1834″ min.

(Without accordion panels)

2STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly.

To adjust for this, attach a piece of wood to the stool.

WOOD PIECES—

WIDTH: 2

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

Wood

1/2″ higher

 

than frame

Stool

 

Storm window frame

11

3PREPARE THE WINDOW

ACut the window sash seal to the window width and stick the adhesive side to the bottom of the sash.

Window sash seal

INSIDE

BMark the centerline of the sill. Measure

and mark the locations for the support brackets 8″ from both sides of the centerline.

CPlace 2 support brackets on the sill,

against the back edge of the stool with their holes centered on each 8″ mark.

Type B screw

Inside

Stool

Sill

Support bracket

Outside Support bracket

DAttach them to the sill with one Type B screw through each support bracket.

Image 11
Contents Air Conditioners Safety Precautions Operating Installation InstructionsRemote Control Support Troubleshooting Tips InstallationAir Direction Power Outage Recovery FeatureCool Mode FAN ModeConsumer Support SafetyInstructions Air Direction Front Grille and Case Care and cleaning of the air conditionerAir Filter Outdoor CoilsTools YOU will Need Before YOU BeginElectrical Requirements Parts Included Installation InstructionsPrepare the Window Window RequirementsStorm Window Requirements Install the AIR Conditioner in the Window Install the Side Accordion PanelsInstall a Support Bracket and the Foam TOP Window Gasket Install the Security BracketProblem Possible Causes What To Do Troubleshooting TipsNormal Operating Sounds Safety Instructions What Is Not Covered GE Air Conditioner Warranty-One Year Limited WarrantyTroubleshooting Tips Consumer Support Order to Make a Warranty ClaimContact Us Parts and AccessoriesAcondicionadores de Aire Operación Instalación ¡ADVERTENCIAUSO DE Cables DE EXTENSIÓN-Modelos de 115 voltios solamente OperaciónControl remoto SeguridadConsumidor Dirección del aire Función de recuperación de pérdida de energíaModo Cool Frio Modo de FAN VentiladorDescripciones de enfriamiento Solucionar problemasServicio al consumidor Controles de modoOperación Precaución no Opere el Instalación Servicio al consumidor Solucionar problemasCuidado y limpieza del acondicionador de aire Requistios Eléctricos Antes DE ComenzarPartes Incluidas Herramientas QUE NecesitaráDE Tormentas Requisitos Para LA VentanaRequisitos DE UNA Ventana Prepare LA VentanaInstale LOS Paneles Laterales DE Acordeon Instale EL Soporte DE Seguridad Problema Causas posibles Qué hacer Solucionar problemasLa función de Sonidos de operación normalesNotas Lo que no está cubierto Seguridad OperaciónNosotros reemplazaremos Para hacer un reclamo de garantíaPóngase en contacto con nosotros Ayuda al Cliente Página Web de GE AppliancesPiezas y accesorios