Nordyne M1M, M1G, M1B, M1S owner manual Troubleshooting Standing Pilot Models, Burner Adjustments

Page 27

Robertshaw

Valve

Figure 34. Convertible Pressure

Regulator

d. To remove the gas valve assembly, remove screw(s) from gas valve bracket. Gas valve and spud may be removed. Orifice is located at the end of the spud (M1G*,M1M*),or re- move three (3) bolts from U-shaped manifold plate and orifice assembly (M1B*).

e. Replace the main orifice with the L.P. gas orifice supplied in the envelope located by the gas valve. Check to insure the orifice size matches the nameplate.

f.It is not necessary to convert the pilot orifice.

g.For Honeywell gas valves with the regulator converter (Figure 33), check for the letters NAT or LP on the pressure regulator cap. Unscrew the cap, invert it, replace, and tighten until snug.

h.For the Robertshaw gas valve with the regu- lator converter (Figure 34), remove the black cover and unscrew the converter located on top of the gas valve. Invert the converter. (For “LP” the red ring will be located at the bottom and the “LP” stamping on the con- verter will appear right side up.) Then screw converter back into the regulator, hand tight plus 1/8 turn, and replace the black cover onto the converter top to protect the threads.

i.Reassemble the burner assembly into the furnace.

j.Reconnect the gas piping and electrical wires to the gas valve.

k.Open the manual shut-off valve and follow the FURNACE START-UP procedure as outlined previously in this manual to put the furnace into operation.

NOTE: The pilot flame is adjustable by turning the adjustment screw located on the gas valve with a small screwdriver. (See Figure 29)

TROUBLESHOOTING - STANDING PILOT MODELS

Main Burner Does Not Come On

a. Check the electrical supply to the furnace. b. Be sure the furnace On-Off switch is in the

“ON” position.

c. Check for proper thermostat operation.

d. Check for broken or open thermostat wires.

e.Check to make sure the insulation located on the inside of the front panel is glued securely around the fan switch and the limit switch.

f.Shut off the electrical supply to the furnace and remove the electrical box cover.

g.Check for a defective transformer or blown fuse.

h.Check electrical circuit for proper grounding, polarity, and make sure the electrical con- nections are tight.

i.Check to see if limit switches may have failed to close.

j.Replace the electrical box cover and restore electrical power to the furnace. Turn the On- Off switch to “ON” and raise the thermostat setting above room temperature.

k.Check for 24 volts at the gas valve.

l.Replace the gas valve if the pilot is estab- lished and it does not open when powered with 24 volts.

Gas Valve Powered (24 volts)– No Main Flame

a. The manual shut-off valve must be on. b. The pilot flame must be established.

c. The gas valve control lever must be in the “ON” position.

d. Check gas pressure coming to the gas valve.

e.Replace the gas valve if the main burner does not come on under the above conditions.

Pilot Will Not Light or Goes Out a. Check the incoming gas pressure.

b. Check for the proper pilot orifice. See the nameplate SPECIFICATION.

c.Check for proper pilot flame adjustment. See

“BURNER ADJUSTMENTS.”

d.Check the thermocouple millivoltage.

Millivoltage should read between 18 and 30 mv.

If the closed millivolt reading is not between 18 and 30 mv., the gas valve electromagnet

27

Image 27
Contents Leave These Instructions with the Homeowner B 056 a B W Table of ContentsGeneral Description SpecificationsMANUFACTURERWARRANTY, OWNER’S Responsibilities Owner Information about Your Central Furnace SystemNat M1 Furnace SpecificationsYou feel that the furnace is not oper Installation StandardsField Installation Blower Assemblies Could cause unsafe operation, exploMinimum Clearances Unit LocationMinimum Clearances Return AIR Provisions27 45 All Weather Roof Jack AssembliesSlant Deck Flashings AIR Distribution SystemsRoof Jack Selection Application NotesNON-PLATINUM Series Duct Connector Selection Platinum SeriesCloset or Alcove Installation CUT OUT Floor Opening & Fuel Line HoleNon-Platinum Series Alternate Attachment Methods Install Roof Jack Install FurnaceInstallation of TRANSIT- Mode Venting System Manufactured Home FactoryManufactured Home Site Electrical Wiring Connect Power Supply WiresConnect Thermostat Wires Control Panel All Models Fuel PipingTypical Gas Piping Thermostat Wire GaugeTypical Oil Piping for Above Ground Single-Line Supply Hook-Up Procedure See Figure How to Eliminate Air LeaksFuel Oil Type Lighting Instructions for STAND- ING Pilot Models Flue GAS SamplingLighting and Shutdown GENERAL-ALL ModelsStanding Pilot Valve Sequence of Operation for STAND- ING PilotM1M Models with Direct Ignition GENERAL-DIRECT Ignition ModelsFurnace if YOU Smell GAS Operating instructions forOil Furnace Honeywell R7184 Control Operating Instructions for OIL and GAS GUN FurnaceOil Gun Model Sequence of Operation for OIL GUN ModelsFurnace Controls and FUNC- Tions Sequence of Operation for GAS GUN ModelsGas Gun Service GuideBurner Adjustments Combustion AIRAtmospheric and Direct Ignition Furnaces Electrode Setting Oil Gun OnlyOil Gun Only GAS ConversionBurner Adjustments Troubleshooting Standing Pilot ModelsControl Module Status Indicators M1M Series Control Module Is Powered Ignitor Does Not Heat Up Troubleshooting Direct Ignition Furnaces Including GAS GUNCad Cell Resistance when Sensing flame Troubleshooting OIL GUNAdditional OIL Furnace Maintenance MaintenanceOptional Accessories By ServicemanDamper without Coil Cavity Non-Platinum Series Only Coil Cavity Damper Non-Platinum Series OnlyCooling Speed/ Evap Coil Wiring Diagrams M1GH 077, 090 Models 710150 08/00 710151 08/00 Blower WireTable Gas and Oil Furnaces, A/C Ready M1 B, S 066, 086 Models High Altitude Equivalent Orifice Sizes AT High Altitudes
Related manuals
Manual 40 pages 53.35 Kb

M1M, M1S, M1B, M1G specifications

Nordyne, a renowned player in the HVAC industry, has introduced a range of high-efficiency gas furnaces, including the M1S, M1G, M1B, and M1M models. Each of these furnaces is designed to provide efficient heating solutions tailored to the needs of homeowners.

The M1S series is well-known for its reliability and performance. It features a single-stage heating process that delivers consistent warmth to any space. With its multi-speed blower, the M1S ensures quiet and comfortable airflow, adapting seamlessly to varying temperature demands. Its robust construction coupled with an energy-efficient design makes it an ideal choice for those looking for dependable heating without sky-high utility bills.

The M1G model steps it up with a two-stage heating system that offers enhanced comfort and efficiency. By operating at a lower speed during milder conditions, the M1G can effectively reduce energy consumption while still maintaining a cozy environment. It is equipped with a variable-speed blower that not only enhances efficiency but also minimizes noise, making it perfect for residential areas. The M1G is designed with advanced safety features, including an integrated control board that monitors furnace functions to ensure optimal performance.

For those seeking a budget-friendly option without compromising on quality, the M1B model provides a solid performance with its straightforward, reliable single-stage heating. While it may lack some of the advanced features found in higher-end models, the M1B is built for ease of use with straightforward controls and maintenance, making it a great option for families.

The M1M model integrates cutting-edge technology with a focus on maximum efficiency. Featuring a modulating gas valve, this model can adjust its output based on real-time heating requirements. This adaptability ensures that the furnace operates at peak efficiency, significantly lowering energy bills and improving overall comfort. The M1M also boasts advanced diagnostic capabilities that allow for easy troubleshooting, thus reducing maintenance time and costs.

In summary, Nordyne's M1 series furnaces—M1S, M1G, M1B, and M1M—offer a range of options to meet diverse heating needs. With technologies designed for efficiency, reliability, and comfort, Nordyne continues to solidify its reputation as a leader in the HVAC market, providing homeowners with effective heating solutions tailored to their lifestyles and budgets.