Nordyne M1G, M1B, M1S, M1M owner manual Coil Cavity Damper Non-Platinum Series Only

Page 32

Figure 37. Coil Cavity Damper (Non-Platinum Series Only)

Figure 38. Damper without Coil Cavity (Non-Platinum Series Only)

Thermostat

 

M1* A/C Ready

 

Furnace

Rc

Red

Red

 

 

RH

 

 

W

White

White

 

 

GGreen Green

Thermostat

 

M1* A/C Ready

 

Furnace

Rc

Red

Red

 

 

RH

 

 

W

White

White

 

 

G

Green

Green

 

 

Y

Yellow Grey

Y

Yellow

Grey

 

 

**

Route Thermostat wire to intended Platinum Series AC/HP location. Coil and secure extra six feet of wire to home's undercarriage.

Platinum Ready Wiring

**

Standard Wiring

Figure 39. Thermostat Wiring A/C Ready Models

32

Image 32
Contents Leave These Instructions with the Homeowner Table of Contents B 056 a B WSpecifications MANUFACTURERWARRANTY, OWNER’S ResponsibilitiesOwner Information about Your Central Furnace System General DescriptionM1 Furnace Specifications NatInstallation Standards Field Installation Blower AssembliesCould cause unsafe operation, explo You feel that the furnace is not operUnit Location Minimum ClearancesReturn AIR Provisions Minimum ClearancesAll Weather Roof Jack Assemblies 27 45AIR Distribution Systems Roof Jack SelectionApplication Notes Slant Deck FlashingsDuct Connector Selection Platinum Series NON-PLATINUM SeriesCloset or Alcove Non-Platinum Series InstallationCUT OUT Floor Opening & Fuel Line Hole Alternate Attachment Methods Install Furnace Install Roof JackManufactured Home Site Installation of TRANSIT- Mode Venting SystemManufactured Home Factory Connect Thermostat Wires Electrical WiringConnect Power Supply Wires Fuel Piping Control Panel All ModelsThermostat Wire Gauge Typical Gas PipingTypical Oil Piping for Above Ground Single-Line Supply Fuel Oil Type Hook-Up Procedure See FigureHow to Eliminate Air Leaks Flue GAS Sampling Lighting and ShutdownGENERAL-ALL Models Lighting Instructions for STAND- ING Pilot ModelsSequence of Operation for STAND- ING Pilot Standing Pilot ValveGENERAL-DIRECT Ignition Models Furnace if YOU Smell GASOperating instructions for M1M Models with Direct IgnitionOperating Instructions for OIL and GAS GUN Furnace Oil Gun ModelSequence of Operation for OIL GUN Models Oil Furnace Honeywell R7184 ControlSequence of Operation for GAS GUN Models Furnace Controls and FUNC- TionsService Guide Burner AdjustmentsCombustion AIR Gas GunElectrode Setting Oil Gun Only Oil Gun OnlyGAS Conversion Atmospheric and Direct Ignition FurnacesTroubleshooting Standing Pilot Models Burner AdjustmentsControl Module Status Indicators M1M Series Troubleshooting Direct Ignition Furnaces Including GAS GUN Control Module Is Powered Ignitor Does Not Heat UpTroubleshooting OIL GUN Cad Cell Resistance when Sensing flameMaintenance Optional AccessoriesBy Serviceman Additional OIL Furnace MaintenanceCoil Cavity Damper Non-Platinum Series Only Damper without Coil Cavity Non-Platinum Series OnlyCooling Speed/ Evap Coil Wiring Diagrams M1GH 077, 090 Models 710150 08/00 710151 08/00 Blower WireTable Gas and Oil Furnaces, A/C Ready M1 B, S 066, 086 Models Equivalent Orifice Sizes AT High Altitudes High Altitude
Related manuals
Manual 40 pages 53.35 Kb

M1M, M1S, M1B, M1G specifications

Nordyne, a renowned player in the HVAC industry, has introduced a range of high-efficiency gas furnaces, including the M1S, M1G, M1B, and M1M models. Each of these furnaces is designed to provide efficient heating solutions tailored to the needs of homeowners.

The M1S series is well-known for its reliability and performance. It features a single-stage heating process that delivers consistent warmth to any space. With its multi-speed blower, the M1S ensures quiet and comfortable airflow, adapting seamlessly to varying temperature demands. Its robust construction coupled with an energy-efficient design makes it an ideal choice for those looking for dependable heating without sky-high utility bills.

The M1G model steps it up with a two-stage heating system that offers enhanced comfort and efficiency. By operating at a lower speed during milder conditions, the M1G can effectively reduce energy consumption while still maintaining a cozy environment. It is equipped with a variable-speed blower that not only enhances efficiency but also minimizes noise, making it perfect for residential areas. The M1G is designed with advanced safety features, including an integrated control board that monitors furnace functions to ensure optimal performance.

For those seeking a budget-friendly option without compromising on quality, the M1B model provides a solid performance with its straightforward, reliable single-stage heating. While it may lack some of the advanced features found in higher-end models, the M1B is built for ease of use with straightforward controls and maintenance, making it a great option for families.

The M1M model integrates cutting-edge technology with a focus on maximum efficiency. Featuring a modulating gas valve, this model can adjust its output based on real-time heating requirements. This adaptability ensures that the furnace operates at peak efficiency, significantly lowering energy bills and improving overall comfort. The M1M also boasts advanced diagnostic capabilities that allow for easy troubleshooting, thus reducing maintenance time and costs.

In summary, Nordyne's M1 series furnaces—M1S, M1G, M1B, and M1M—offer a range of options to meet diverse heating needs. With technologies designed for efficiency, reliability, and comfort, Nordyne continues to solidify its reputation as a leader in the HVAC market, providing homeowners with effective heating solutions tailored to their lifestyles and budgets.