Installer’s Guide

High Efficiency Single Stage Upflow/ Horizontal

and Downflow/ Horizontal Gas-Fired Furnaces,

“Fan Assisted Combustion System”

*UD1A040A9H21B *UD1B100A9H31B *DD1B060A9H31B *UD1B060A9H31B *UD1C100A9H51B *DD1B080A9H31B *UD1B080A9H31B *UD1D120A9H51B *DD1C100A9H51B *UD1C080A9H41B *UD1D140A9H51B *DD1D120A9H51B

*__First letter may be “A” or “T”

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

IMPORTANT — This Document is customer property and is to remain with this unit.

Please return to service information pack upon completion of work.

For VENT SIZING INFORMATION see:

 

USA

 

 

National Fuel Gas Code

ANSI Z223.1/NFPA 54 (latest version)

CANADA

 

 

Natural Gas Installation Code

CAN/CGA-B149.1

(latest version)

Propane Installation Code

CAN/CGA-B149.2

(latest version)

USA/CANADA ALTERNATE —

 

 

Category I Venting Guide .................................. Pub. No. 18-CH23D1-2

 

 

 

*UD1-H

*DD1-H

Upflow/ Horizontal*

Downflow/ Horizontal*

*Horizontal Conversion for these furnaces may be left or right side rotation.

A341789P07

Image 1
Contents USA/CANADA Alternate CanadaCarbon Monoxide Poisoning Hazard Safety SectionInstaller’s Guide Contents Location and Clearances General Installation InstructionsDrawing DD1-HF Outline Drawing Upflow Installation Downflow InstallationHorizontal Installation Required Floor Opening DownflowInput ALL Equip Ment Installed Input ALL EQUIP- Ment InstalledAIR for Combustion and Ventilation Less than 50 CU. FTMinimum Free Area in Square Inches Each Opening Furnace only Return AIR Duct Connection Duct ConnectionsBottom Filter Rack Installation Typical Upflow Return AIR Filter InstallationsReturn AIR Filters FilterAirf low Optional Filter Rack Installation for Bottom ReturnFilter Rack Retaining Screw/Pin Filter Bottom Panel Typical Downflow Furnace Return AIR Filter InstallationsCabinet Filter Filter Bracket Width Size Location General Venting InstructionsVenting Into a Masonry Chimney Vent PipingInternal Masonry Chimneys Carbon Monoxide Poisoning HazardGAS Vent Termination Electrical ConnectionsFurnace See Stage Heating only Thermostat TwinningSequence of Operation Thermostat Call for Heat GAS PipingPreliminary Inspections START-UP and AdjustmentCombustion and Input Check Orifice Sizes Part Numbers for Replacement OrificesHigh Altitude Derate To Shut OFF Lighting InstructionsGAS Flow in Cubic Feet PER Hour Cubic Foot Dial Operating Information Control and Safety Switch AdjustmentWhat to do if YOU Smell GAS Integrated Furnace Control Error Flash Codes