Trane TUH2D120A9V5VA, TUH2C100A9V5VA, TUH2C100A9V4VA, TUH2B080A9V3VA Stage Medium OFF TEMP. Rise

Page 13

*UH2C100A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

1st Stage Capacity =

62,855

 

 

 

 

 

 

 

2nd Stage Capacity =

96,700

 

 

 

AIRFLOW

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

SW 7

SW 8

 

0.1

0.3

0.5

0.7

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

873

893

900

899

902

 

LOW

ON

ON

TEMP. RISE

64

63

62

62

62

 

 

 

 

WATTS

100

145

195

240

290

 

 

 

 

CFM

971

997

1006

1022

1029

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

58

56

56

55

54

 

 

 

WATTS

115

170

220

280

335

1ST

 

 

 

 

 

 

CFM

1136

1146

1165

1180

1184

STAGE

 

 

 

MEDIUM **

ON

OFF

TEMP. RISE

49

49

48

47

47

 

 

 

 

 

WATTS

160

230

295

365

425

 

 

 

 

CFM

1258

1298

1319

1328

1286

 

HIGH

OFF

OFF

TEMP. RISE

44

43

42

42

44

 

 

 

 

WATTS

225

300

390

450

490

 

 

 

 

CFM

1260

1304

1329

1334

1317

 

LOW

ON

ON

TEMP. RISE

68

66

65

65

65

 

 

 

 

WATTS

213

305

380

460

510

 

 

 

 

CFM

1464

1471

1478

1478

1350

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

59

59

58

58

64

 

 

 

WATTS

315

405

485

560

540

2ND

 

 

 

 

 

 

CFM

1631

1678

1690

1579

1419

STAGE

 

 

 

MEDIUM **

ON

OFF

TEMP. RISE

53

51

51

55

61

 

 

 

 

 

WATTS

450

570

670

645

585

 

 

 

 

CFM

1846

1867

1794

1644

1498

 

HIGH

OFF

OFF

TEMP. RISE

47

46

48

52

57

 

 

 

 

WATTS

640

760

770

700

650

NOTES:

*First letter may be "A" or "T" ** Factory setting

*UH2C100A9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

UNIT SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

(TONS)

SW 1

SW 2

SW 3

SW 4

 

0.1

 

0.3

0.5

0.7

 

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

ON

OFF

ON

CFM

1163

 

1201

1209

1200

 

1199

 

(350 CFM/TON)

 

WATTS

222

 

304

375

433

 

495

 

 

 

 

 

 

 

 

3.5

NORMAL

OFF

 

ON

OFF

OFF

CFM

1339

 

1365

1366

1377

 

1382

(400 CFM/TON)

 

WATTS

331

 

400

477

555

 

636

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

ON

ON

OFF

CFM

1515

 

1538

1549

1553

 

1547

 

(450 CFM/TON)

 

WATTS

440

 

535

620

708

 

796

 

 

 

 

 

 

 

 

 

LOW

 

 

 

 

 

CFM

1339

 

1365

1366

1377

 

1382

 

(350 CFM/TON)

ON

 

OFF

OFF

ON

 

 

 

 

WATTS

331

 

400

477

555

 

636

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.0

NORMAL

 

 

 

 

 

CFM

1550

 

1562

1574

1575

 

1564

(400 CFM/TON)

ON

 

OFF

OFF

OFF

 

 

 

 

WATTS

471

 

550

645

733

 

813

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

OFF

ON

OFF

CFM

1744

 

1758

1770

1772

 

1760

 

(450 CFM/TON)

 

WATTS

626

 

736

838

935

 

1018

 

 

 

 

 

 

 

 

 

LOW

OFF

 

OFF

OFF

ON

CFM

1695

 

1709

1721

1772

 

1711

 

(350 CFM/TON)

 

WATTS

578

 

728

820

930

 

1007

 

 

 

 

 

 

 

 

5.0

NORMAL

OFF

 

OFF

OFF

OFF

CFM

1919

 

1919

1905

1831

 

1709

(400 CFM/TON)

 

WATTS

862

 

958

1043

1043

 

982

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

OFF

ON

OFF

CFM

NA

 

NA

NA

NA

 

NA

 

(450 CFM/TON)

 

WATTS

NA

 

NA

NA

NA

 

NA

 

 

 

 

 

 

 

 

NOTES: *First letter may be "A" or "T"

1.At Continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.

2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;

HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.

3.NA = Not allowed.

13

Pub. No. 22-1814-08

Image 13
Contents PUB. no Natural GAS Models General FeaturesContents XV 95 Standard Equipment Features BenefitsXV 95 Optional Equipment General Data TUH2 Product SPECIFICATIONS1TUH2/TDH2 Product SPECIFICATIONS1 Product Specifications TDH2 Product SPECIFICATIONS1 Product Specifications Airflow DIP Switch Setting External Static Pressure CFM Medium LOW OFF TEMP. Rise Heating Heating LOW TEMP. Rise Airflow DIP Switch Setting External Static Pressure SW8 CFM Stage Medium OFF TEMP. Rise Heating Medium LOW OFF TEMP. Rise 1ST 1st Stage Capacity = 37,440 2nd Stage Capacity = 57,600 1st Stage Capacity = 49,920 2nd Stage Capacity = 76,800 1st Stage Capacity = 49,400 2nd Stage Capacity = 76,000 1st Stage Capacity = 62,400 2nd Stage Capacity = 96,000 Medium LOW CFM Maximum Vent Length Table Electrical Data UH2 Wiring DiagramUH2 Schematic Diagram DH2 Wiring Diagram DH2 Schematic Diagram Field WiringField Wiring UPFLOW / HORIZONTAL Outline Drawing DimensionsDH2 DOWNFLOW / HORIZONTAL Outline DrawingPub. No Trane

TDH2B060A9V3VA, TDH2B080A9V4VA, TDH2B080A9V3VA, TDH2D120A9V5VA, TDH2C100A9V4VA specifications

Trane is renowned for its commitment to energy efficiency, innovation, and reliability, exemplified in its range of TUH2 series air handlers. Among these models, the TUH2C100A9V5VA, TUH2C100A9V4VA, TUH2D120A9V5VA, TUH2B080A9V3VA, and TUH2B080A9V4VA stand out with their advanced features and technologies designed to enhance indoor comfort and operational efficiency.

The TUH2C100A9V5VA and TUH2C100A9V4VA are both equipped for versatile applications, making them suitable for residential and light commercial purposes. These models feature a durable construction that ensures longevity even in demanding environments. Their design incorporates a high-efficiency blower that allows for optimized airflow, ensuring a balanced temperature throughout the space.

The TUH2D120A9V5VA model is tailored specifically for larger applications, providing enhanced performance and increased capacity. Its dual-stage heating function guarantees consistent warmth during colder months, while the integrated energy recovery ventilator contributes to improved indoor air quality by allowing for better ventilation. This model is particularly beneficial in increasingly energy-conscious markets, demonstrating Trane's commitment to sustainability.

Both the TUH2B080A9V3VA and TUH2B080A9V4VA are designed for maximum efficiency in smaller applications. They utilize variable speed technology, allowing them to adjust the airflow according to fluctuating demand. This efficient operation not only reduces energy consumption but also minimizes noise levels, creating a more comfortable and peaceful indoor environment.

All models in the TUH2 series feature advanced diagnostics and communication capabilities, enabling remote monitoring and management of the systems. This technology helps property owners track performance and energy usage in real-time, facilitating proactive maintenance and improving overall system reliability.

Trane's TUH2 series is built with a focus on quality and innovation, utilizing high-grade materials to withstand various environmental factors. Each unit is engineered for easy installation and maintenance, ensuring that technicians can efficiently service these robust systems. In summary, the TUH2 series air handlers provide a blend of performance, efficiency, and user-friendly features, making them an excellent choice for any indoor climate control needs.