*UH2D120A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

1st Stage Capacity =

75,426

 

 

 

 

 

 

 

2nd Stage Capacity =

116,040

 

 

 

AIRFLOW

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

SW 7

SW 8

 

0.1

0.3

0.5

0.7

0.9

 

 

 

 

CFM

1090

1120

1080

1070

1010

 

LOW

ON

ON

TEMP. RISE

62

60

63

63

67

 

 

 

 

WATTS

165

225

270

310

380

 

 

 

 

CFM

1210

1200

1200

1180

1160

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

56

56

56

57

58

1ST

 

 

 

WATTS

220

280

330

395

455

STAGE

 

 

 

CFM

1340

1360

1370

1380

1330

 

NORMAL **

ON

OFF

TEMP. RISE

50

50

49

49

51

 

 

 

 

WATTS

295

350

425

495

535

 

 

 

 

CFM

1430

1570

1580

1570

1390

 

HIGH

OFF

OFF

TEMP. RISE

47

43

43

43

49

 

 

 

 

WATTS

390

490

565

625

565

 

 

 

 

CFM

1660

1690

1680

1640

1460

 

LOW

ON

ON

TEMP. RISE

63

62

62

64

72

 

 

 

 

WATTS

485

590

640

675

600

 

 

 

 

CFM

1870

1870

1810

1680

1490

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

56

56

58

62

70

 

 

 

WATTS

675

745

770

715

625

2ND

 

 

 

 

 

 

CFM

2060

1990

1850

1710

1530

STAGE

 

 

 

NORMAL **

ON

OFF

TEMP. RISE

51

53

57

61

68

 

 

 

 

 

WATTS

880

890

810

750

665

 

 

 

 

CFM

2200

2090

1940

1790

1640

 

HIGH

OFF

OFF

TEMP. RISE

48

50

54

58

64

 

 

 

 

WATTS

1030

965

895

830

750

NOTES:

*First letter may be "A" or "T" ** Factory setting

*UH2D120A9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

UNIT SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTING

SW 1

SW 2

SW 3

SW 4

 

0.1

 

0.3

0.5

0.7

 

0.9

(TONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

ON

OFF

ON

CFM

1210

 

1210

1220

1230

 

1230

 

(350 CFM/TON)

 

WATTS

220

 

270

325

400

 

445

 

 

 

 

 

 

 

 

3.5

NORMAL

OFF

 

ON

OFF

OFF

CFM

1400

 

1440

1450

1450

 

1410

(400 CFM/TON)

 

WATTS

305

 

390

465

510

 

560

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

ON

ON

OFF

CFM

1590

 

1600

1610

1600

 

1380

 

(450 CFM/TON)

 

WATTS

425

 

520

600

645

 

575

 

 

 

 

 

 

 

 

 

LOW

ON

 

OFF

OFF

ON

CFM

1390

 

1400

1430

1440

 

1420

 

(350 CFM/TON)

 

WATTS

305

 

375

445

515

 

565

 

 

 

 

 

 

 

 

4.0

NORMAL

ON

 

OFF

OFF

OFF

CFM

1620

 

1650

1670

1640

 

1480

(400 CFM/TON)

 

WATTS

420

 

530

595

660

 

600

 

 

 

 

 

 

 

 

 

HIGH

ON

 

OFF

ON

OFF

CFM

1840

 

1830

1820

1670

 

1490

 

(450 CFM/TON)

 

WATTS

600

 

690

765

700

 

620

 

 

 

 

 

 

 

 

 

LOW

OFF

 

OFF

OFF

ON

CFM

1800

 

1780

1780

1700

 

1530

 

(350 CFM/TON)

 

WATTS

570

 

630

705

695

 

615

 

 

 

 

 

 

 

 

5

NORMAL

OFF

 

OFF

OFF

OFF

CFM

2050

 

2010

1860

1710

 

1530

(400 CFM/TON)

 

WATTS

845

 

875

805

735

 

655

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

OFF

ON

OFF

CFM

2160

 

2040

1920

1780

 

1620

 

(450 CFM/TON)

 

WATTS

995

 

935

875

805

 

730

 

 

 

 

 

 

 

 

NOTES: * First letter may be "A" or "T"

1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.

2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;

HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.

14

Pub. No. 22-1814-08

Image 14
Contents PUB. no General Features Natural GAS ModelsContents Features Benefits XV 95 Standard EquipmentXV 95 Optional Equipment TUH2 Product SPECIFICATIONS1 General DataTUH2/TDH2 Product SPECIFICATIONS1 Product Specifications TDH2 Product SPECIFICATIONS1 Product Specifications Airflow DIP Switch Setting External Static Pressure CFM Medium LOW OFF TEMP. Rise Heating Heating LOW TEMP. Rise Airflow DIP Switch Setting External Static Pressure SW8 CFM Stage Medium OFF TEMP. Rise Heating Medium LOW OFF TEMP. Rise 1ST 1st Stage Capacity = 37,440 2nd Stage Capacity = 57,600 1st Stage Capacity = 49,920 2nd Stage Capacity = 76,800 1st Stage Capacity = 49,400 2nd Stage Capacity = 76,000 1st Stage Capacity = 62,400 2nd Stage Capacity = 96,000 Medium LOW CFM Maximum Vent Length Table UH2 Wiring Diagram Electrical DataUH2 Schematic Diagram DH2 Wiring Diagram DH2 Schematic Diagram Wiring FieldField Wiring Dimensions UPFLOW / HORIZONTAL Outline DrawingDOWNFLOW / HORIZONTAL Outline Drawing DH2Pub. No Trane

TDH2B060A9V3VA, TDH2B080A9V4VA, TDH2B080A9V3VA, TDH2D120A9V5VA, TDH2C100A9V4VA specifications

Trane is renowned for its commitment to energy efficiency, innovation, and reliability, exemplified in its range of TUH2 series air handlers. Among these models, the TUH2C100A9V5VA, TUH2C100A9V4VA, TUH2D120A9V5VA, TUH2B080A9V3VA, and TUH2B080A9V4VA stand out with their advanced features and technologies designed to enhance indoor comfort and operational efficiency.

The TUH2C100A9V5VA and TUH2C100A9V4VA are both equipped for versatile applications, making them suitable for residential and light commercial purposes. These models feature a durable construction that ensures longevity even in demanding environments. Their design incorporates a high-efficiency blower that allows for optimized airflow, ensuring a balanced temperature throughout the space.

The TUH2D120A9V5VA model is tailored specifically for larger applications, providing enhanced performance and increased capacity. Its dual-stage heating function guarantees consistent warmth during colder months, while the integrated energy recovery ventilator contributes to improved indoor air quality by allowing for better ventilation. This model is particularly beneficial in increasingly energy-conscious markets, demonstrating Trane's commitment to sustainability.

Both the TUH2B080A9V3VA and TUH2B080A9V4VA are designed for maximum efficiency in smaller applications. They utilize variable speed technology, allowing them to adjust the airflow according to fluctuating demand. This efficient operation not only reduces energy consumption but also minimizes noise levels, creating a more comfortable and peaceful indoor environment.

All models in the TUH2 series feature advanced diagnostics and communication capabilities, enabling remote monitoring and management of the systems. This technology helps property owners track performance and energy usage in real-time, facilitating proactive maintenance and improving overall system reliability.

Trane's TUH2 series is built with a focus on quality and innovation, utilizing high-grade materials to withstand various environmental factors. Each unit is engineered for easy installation and maintenance, ensuring that technicians can efficiently service these robust systems. In summary, the TUH2 series air handlers provide a blend of performance, efficiency, and user-friendly features, making them an excellent choice for any indoor climate control needs.