Trane TDH2D120A9V5VA, TUH2C100A9V5VA manual 1st Stage Capacity = 49,920 2nd Stage Capacity = 76,800

Page 16

*DH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

1st STAGE CAPACITY =

49,920

 

 

 

 

 

 

 

2nd STAGE CAPACITY = 76,800

 

 

 

AIRFLOW

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

SW 7

SW 8

 

0.1

0.3

0.5

0.7

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

800

800

800

790

 

 

LOW

ON

ON

TEMP. RISE

56

56

56

56

-

 

 

 

 

WATTS

130

170

210

245

 

 

 

 

 

CFM

900

900

900

900

 

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

49

49

49

49

-

 

 

 

WATTS

162

210

260

295

 

1ST

 

 

 

 

 

 

 

CFM

1000

1000

1000

1000

800

STAGE

 

 

 

NORMAL **

ON

OFF

TEMP. RISE

44

44

44

44

56

 

 

 

 

 

WATTS

205

265

310

345

295

 

 

 

 

CFM

1170

1170

1170

1020

830

 

HIGH

OFF

OFF

TEMP. RISE

38

38

38

44

54

 

 

 

 

WATTS

305

350

400

360

310

 

 

 

 

CFM

1150

1150

1150

1020

830

 

LOW

ON

ON

TEMP. RISE

60

60

60

67***

83***

 

 

 

 

WATTS

285

345

385

360

305

 

 

 

 

CFM

1275

1275

1200

1040

900

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

54

54

57

66***

76***

 

 

 

WATTS

380

445

425

380

350

2ND

 

 

 

 

 

 

CFM

1430

1340

1220

1090

930

STAGE

 

 

 

NORMAL **

ON

OFF

TEMP. RISE

48

51

56

63

74***

 

 

 

 

 

WATTS

515

490

455

410

380

 

 

 

 

CFM

1430

1340

1220

1090

930

 

HIGH

OFF

OFF

TEMP. RISE

48

51

56

63

74***

 

 

 

 

WATTS

515

490

455

410

380

NOTES: * - First letter may be "A" or "T"

**Factory setting

***Above MAX Temperature change value

*DH2B080A9V3V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

UNIT SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

SETTING

SW 1

SW 2

SW 3

SW 4

 

0.1

 

0.3

0.5

0.7

 

0.9

(TONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

ON

OFF

ON

CFM

700

 

700

700

680

 

670

 

(350 CFM/TON)

 

WATTS

95

 

105

115

200

 

235

 

 

 

 

 

 

 

 

2.0

NORMAL

ON

 

ON

OFF

OFF

CFM

800

 

800

800

790

 

740

(400 CFM/TON)

 

WATTS

130

 

160

205

245

 

265

 

 

 

 

 

 

 

 

 

HIGH

ON

 

ON

ON

OFF

CFM

900

 

900

900

900

 

750

 

(450 CFM/TON)

 

WATTS

160

 

215

255

300

 

270

 

 

 

 

 

 

 

 

 

LOW

OFF

 

ON

OFF

ON

CFM

875

 

875

875

875

 

760

 

(350 CFM/TON)

 

WATTS

145

 

185

240

280

 

270

 

 

 

 

 

 

 

 

2.5

NORMAL

OFF

 

ON

OFF

OFF

CFM

1000

 

1000

1000

1000

 

800

(400 CFM/TON)

 

WATTS

205

 

265

310

340

 

295

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

ON

ON

OFF

CFM

1150

 

1150

1150

1020

 

800

 

(450 CFM/TON)

 

WATTS

295

 

340

385

350

 

300

 

 

 

 

 

 

 

 

 

LOW

ON

 

OFF

OFF

ON

CFM

1050

 

1050

1050

1010

 

800

 

(350 CFM/TON)

 

WATTS

235

 

295

340

350

 

290

 

 

 

 

 

 

 

 

3.0

NORMAL

ON

 

OFF

OFF

OFF

CFM

1200

 

1200

1200

1040

 

840

(400 CFM/TON)

 

WATTS

335

 

385

410

365

 

310

 

 

 

 

 

 

 

 

 

HIGH

ON

 

OFF

ON

OFF

CFM

1350

 

1350

1210

1070

 

900

 

(450 CFM/TON)

 

WATTS

455

 

480

435

390

 

345

 

 

 

 

 

 

 

 

NOTES: * First letter may be "A" or "T"

1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.

2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting;

HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.

16

Pub. No. 22-1814-08

Image 16
Contents PUB. no General Features Natural GAS ModelsContents Features Benefits XV 95 Standard EquipmentXV 95 Optional Equipment TUH2 Product SPECIFICATIONS1 General DataTUH2/TDH2 Product SPECIFICATIONS1 Product Specifications TDH2 Product SPECIFICATIONS1 Product Specifications Airflow DIP Switch Setting External Static Pressure CFM Medium LOW OFF TEMP. Rise Heating Heating LOW TEMP. Rise Airflow DIP Switch Setting External Static Pressure SW8 CFM Stage Medium OFF TEMP. Rise Heating Medium LOW OFF TEMP. Rise 1ST 1st Stage Capacity = 37,440 2nd Stage Capacity = 57,600 1st Stage Capacity = 49,920 2nd Stage Capacity = 76,800 1st Stage Capacity = 49,400 2nd Stage Capacity = 76,000 1st Stage Capacity = 62,400 2nd Stage Capacity = 96,000 Medium LOW CFM Maximum Vent Length Table UH2 Wiring Diagram Electrical DataUH2 Schematic Diagram DH2 Wiring Diagram DH2 Schematic Diagram Wiring FieldField Wiring Dimensions UPFLOW / HORIZONTAL Outline DrawingDOWNFLOW / HORIZONTAL Outline Drawing DH2Pub. No Trane

TDH2B060A9V3VA, TDH2B080A9V4VA, TDH2B080A9V3VA, TDH2D120A9V5VA, TDH2C100A9V4VA specifications

Trane is renowned for its commitment to energy efficiency, innovation, and reliability, exemplified in its range of TUH2 series air handlers. Among these models, the TUH2C100A9V5VA, TUH2C100A9V4VA, TUH2D120A9V5VA, TUH2B080A9V3VA, and TUH2B080A9V4VA stand out with their advanced features and technologies designed to enhance indoor comfort and operational efficiency.

The TUH2C100A9V5VA and TUH2C100A9V4VA are both equipped for versatile applications, making them suitable for residential and light commercial purposes. These models feature a durable construction that ensures longevity even in demanding environments. Their design incorporates a high-efficiency blower that allows for optimized airflow, ensuring a balanced temperature throughout the space.

The TUH2D120A9V5VA model is tailored specifically for larger applications, providing enhanced performance and increased capacity. Its dual-stage heating function guarantees consistent warmth during colder months, while the integrated energy recovery ventilator contributes to improved indoor air quality by allowing for better ventilation. This model is particularly beneficial in increasingly energy-conscious markets, demonstrating Trane's commitment to sustainability.

Both the TUH2B080A9V3VA and TUH2B080A9V4VA are designed for maximum efficiency in smaller applications. They utilize variable speed technology, allowing them to adjust the airflow according to fluctuating demand. This efficient operation not only reduces energy consumption but also minimizes noise levels, creating a more comfortable and peaceful indoor environment.

All models in the TUH2 series feature advanced diagnostics and communication capabilities, enabling remote monitoring and management of the systems. This technology helps property owners track performance and energy usage in real-time, facilitating proactive maintenance and improving overall system reliability.

Trane's TUH2 series is built with a focus on quality and innovation, utilizing high-grade materials to withstand various environmental factors. Each unit is engineered for easy installation and maintenance, ensuring that technicians can efficiently service these robust systems. In summary, the TUH2 series air handlers provide a blend of performance, efficiency, and user-friendly features, making them an excellent choice for any indoor climate control needs.