Trane 120R9V, 080, XV 90, 100 manual 1450

Page 10

Performance

Data

TUY120R9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

 

EXTERNAL STATIC PRESSURE

 

UNIT SIZE

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW 1

 

SW 2

SW 3

 

SW 4

 

0.1

 

0.3

0.5

0.7

 

0.9

(TONS)

(See Notes)

 

 

 

 

 

 

LOW

OFF

 

ON

OFF

 

ON

CFM

1210

 

1210

1220

1230

 

1230

 

(350 CFM/TON)

 

 

WATTS

220

 

270

325

400

 

445

 

 

 

 

 

 

 

 

 

3.5

NORMAL

OFF

 

ON

OFF

 

OFF

CFM

1400

 

1440

1450

1450

 

1410

(400 CFM/TON)

 

 

WATTS

305

 

390

465

510

 

560

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

ON

ON

 

OFF

CFM

1590

 

1600

1610

1600

 

1380

 

(450 CFM/TON)

 

 

WATTS

425

 

520

600

645

 

575

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

OFF

OFF

 

ON

CFM

1390

 

1400

1430

1440

 

1420

 

(350 CFM/TON)

 

 

WATTS

305

 

375

445

515

 

565

 

 

 

 

 

 

 

 

 

4.0

NORMAL

ON

 

OFF

OFF

 

OFF

CFM

1620

 

1650

1670

1640

 

1480

(400 CFM/TON)

 

 

WATTS

420

 

530

595

660

 

600

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

OFF

ON

 

OFF

CFM

1840

 

1830

1820

1670

 

1490

 

(450 CFM/TON)

 

 

WATTS

600

 

690

765

700

 

620

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

OFF

OFF

 

ON

CFM

1800

 

1780

1780

1700

 

1530

 

(350 CFM/TON)

 

 

WATTS

570

 

630

705

695

 

615

 

 

 

 

 

 

 

 

 

5

NORMAL

OFF

 

OFF

OFF

 

OFF

CFM

2050

 

2010

1860

1710

 

1530

(400 CFM/TON)

 

 

WATTS

845

 

875

805

735

 

655

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

OFF

ON

 

OFF

CFM

2160

 

2040

1920

1780

 

1620

 

(450 CFM/TON)

 

 

WATTS

995

 

935

875

805

 

730

 

 

 

 

 

 

 

 

 

NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.

1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.

2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;

NORMAL airflow (400 cfm/ton) is typical setting;

HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.

TUY120R9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

1st Stage Capacity =

74,000

 

 

 

 

 

 

 

2nd Stage Capacity =

112,000

 

 

 

AIRFLOW

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

 

 

 

 

 

 

 

 

 

 

SETTING

SW 7

SW 8

 

0.1

0.3

0.5

0.7

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1090

1120

1080

1070

1010

 

LOW

ON

ON

TEMP. RISE

62

60

63

63

67

 

 

 

 

WATTS

165

225

270

310

380

 

 

 

 

CFM

1210

1200

1200

1180

1160

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

56

56

56

57

58

 

 

 

WATTS

220

280

330

395

455

1ST

 

 

 

 

 

 

CFM

1340

1360

1370

1380

1330

STAGE

 

 

 

NORMAL **

ON

OFF

TEMP. RISE

50

50

49

49

51

 

 

 

 

 

WATTS

295

350

425

495

535

 

 

 

 

CFM

1430

1570

1580

1570

1390

 

HIGH

OFF

OFF

TEMP. RISE

47

43

43

43

49

 

 

 

 

WATTS

390

490

565

625

565

 

 

 

 

CFM

1660

1690

1680

1640

1460

 

LOW

ON

ON

TEMP. RISE

63

62

62

64

72

 

 

 

 

WATTS

485

590

640

675

600

 

 

 

 

CFM

1870

1870

1810

1680

1490

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

56

56

58

62

70

 

 

 

WATTS

675

745

770

715

625

2ND

 

 

 

 

 

 

CFM

2060

1990

1850

1710

1530

STAGE

 

 

 

NORMAL **

ON

OFF

TEMP. RISE

51

53

57

61

68

 

 

 

 

 

WATTS

880

890

810

750

665

 

 

 

 

CFM

2200

2090

1940

1790

1640

 

HIGH

OFF

OFF

TEMP. RISE

48

50

54

58

64

 

 

 

 

WATTS

1030

965

895

830

750

NOTES:

** Factory setting

10

Pub. No. 22-1682-05-0802 (EN)

Image 10
Contents Upflow/Horizontal Two-stage Condensing Gas-Fired Furnace General Features Contents Features Benefits XV 90 Standard EquipmentOptional Equipment TAYSTAT241TUY-R9V Product SPECIFICATIONS1 General DataPerformance Data Tons 1030 1450 Schematic Diagrams for GAS Furnaces Electrical DataField Wiring Diagram for Single Stage Heating Field WiringField Wiring Diagram for 2 Stage Heating Thermostat Field From Dwg B341128 Rev Pub. No -1682-05-0802 EN Dimensions Trane

100, 120R9V, XV 90, 080 specifications

The Trane XV 90, 100, 120R9V, and 080 are part of Trane's exceptional range of high-efficiency gas furnaces, designed to deliver optimal heating performance while minimizing energy consumption. These models are synonymous with reliability, comfort, and innovative technology, making them ideal for residential heating requirements.

One of the standout features of the Trane XV series is its variable-speed blower motor. This technology allows for precise adjustments to airflow, leading to more consistent temperatures throughout the home. The variable speed operation reduces noise levels, making for a quieter heating experience, and enhances energy efficiency by operating at lower settings for most of the heating cycle.

Another key characteristic of the Trane XV models is their impressive AFUE (Annual Fuel Utilization Efficiency) ratings. With efficiencies reaching up to 97%, these furnaces use significantly less fuel than traditional models, resulting in lower utility bills and reduced environmental impact. This high efficiency is achieved through a two-stage heating process, which allows the furnace to run at a lower stage for longer periods when less heating is needed.

The Trane XV series furnaces also feature integrated communicating technology. This allows the unit to seamlessly connect with other Trane smart home products and thermostats, providing users with greater control over their indoor climate. Homeowners can easily monitor and manage their heating system from anywhere, ensuring maximum comfort and efficiency.

Durability is another hallmark of Trane's engineering excellence. The XV models are designed with rugged components, including a fully insulated cabinet that minimizes heat loss and prevents cold drafts. The trapezoidal heat exchanger is engineered for longevity, while the corrosion-resistant materials used in construction ensure the furnace will withstand harsh environmental conditions for years.

Safety is paramount in the design of the Trane XV models. They come equipped with advanced safety features, including an electronic control board that monitors the system for any irregularities, ensuring reliable operation and peace of mind.

In summary, the Trane XV 90, 100, 120R9V, and 080 gas furnaces are a testament to advanced heating technology. With variable-speed blower motors, high AFUE ratings, smart connectivity, durability, and safety features, these models provide efficient and effective heating solutions tailored to modern living. Homeowners can invest in comfort with the assurance of quality and innovation that Trane is known for.