Performance

Data

TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

 

EXTERNAL STATIC PRESSURE

 

UNIT SIZE

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TONS)

(See Notes)

SW 1

 

SW 2

SW 3

 

SW 4

 

0.1

 

0.3

0.5

0.7

 

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

ON

OFF

 

ON

CFM

750

 

750

750

720

 

710

 

(350 CFM/TON)

 

 

WATTS

84

 

122

154

185

 

221

 

 

 

 

 

 

 

 

 

2.0

NORMAL

ON

 

ON

OFF

 

OFF

CFM

840

 

840

840

840

 

820

(400 CFM/TON)

 

 

WATTS

109

 

146

181

226

 

264

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

ON

ON

 

OFF

CFM

940

 

940

940

940

 

940

 

(450 CFM/TON)

 

 

WATTS

136

 

177

215

274

 

318

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

ON

OFF

 

ON

CFM

850

 

850

870

890

 

890

 

(350 CFM/TON)

 

 

WATTS

113

 

150

200

250

 

295

 

 

 

 

 

 

 

 

 

2.5

NORMAL

OFF

 

ON

OFF

 

OFF

CFM

960

 

990

1000

1020

 

1010

(400 CFM/TON)

 

 

WATTS

150

 

200

230

305

 

350

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

ON

ON

 

OFF

CFM

1080

 

1110

1120

1120

 

1080

 

(450 CFM/TON)

 

 

WATTS

195

 

255

315

365

 

390

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

OFF

OFF

 

ON

CFM

1020

 

1020

1040

1050

 

1050

 

(350 CFM/TON)

 

 

WATTS

175

 

225

280

330

 

375

 

 

 

 

 

 

 

 

 

3.0

NORMAL

ON

 

OFF

OFF

 

OFF

CFM

1170

 

1180

1200

1200

 

1130

(400 CFM/TON)

 

 

WATTS

240

 

300

365

415

 

420

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

OFF

ON

 

OFF

CFM

1290

 

1320

1350

1340

 

1150

 

(450 CFM/TON)

 

 

WATTS

310

 

410

470

520

 

440

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

OFF

OFF

 

ON

CFM

1170

 

1190

1210

1210

 

1100

 

(350 CFM/TON)

 

 

WATTS

250

 

315

370

435

 

405

 

 

 

 

 

 

 

 

 

3.5

NORMAL

OFF

 

OFF

OFF

 

OFF

CFM

1360

 

1390

1400

1360

 

1210

(400 CFM/TON)

 

 

WATTS

365

 

445

500

535

 

475

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

OFF

ON

 

OFF

CFM

1360

 

1390

1400

1350

 

1180

 

(450 CFM/TON)

 

 

WATTS

355

 

450

520

535

 

460

 

 

 

 

 

 

 

 

 

NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.

1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.

2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;

NORMAL airflow (400 cfm/ton) is typical setting;

HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.

TUY080R9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

1st Stage Capacity =

49,000

 

 

 

 

 

 

 

2nd Stage Capacity =

73,000

 

 

 

AIRFLOW

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

 

 

 

 

 

 

 

 

 

 

SETTING

SW 7

SW 8

 

0.1

0.3

0.5

0.7

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

800

800

800

800

800

 

LOW

ON

ON

TEMP. RISE

56

56

56

56

56

 

 

 

 

WATTS

105

140

180

220

265

 

 

 

 

CFM

860

880

890

920

910

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

52

51

50

48

49

 

 

 

WATTS

115

165

215

265

320

1ST

 

 

 

 

 

 

CFM

960

990

1000

1020

1010

STAGE

 

 

 

NORMAL **

ON

OFF

TEMP. RISE

46

45

44

44

44

 

 

 

 

 

WATTS

150

200

230

310

350

 

 

 

 

CFM

1080

1110

1120

1120

1080

 

HIGH

OFF

OFF

TEMP. RISE

41

40

40

40

41

 

 

 

 

WATTS

195

255

315

365

390

 

 

 

 

CFM

1100

1100

1120

1120

1090

 

LOW

ON

ON

TEMP. RISE

62

62

61

61

63

 

 

 

 

WATTS

205

260

320

370

400

 

 

 

 

CFM

1210

1240

1260

1260

1130

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

57

55

54

54

61

 

 

 

WATTS

265

340

410

470

430

2ND

 

 

 

 

 

 

CFM

1360

1390

1400

1360

1210

STAGE

 

 

 

NORMAL **

ON

OFF

TEMP. RISE

50

49

49

50

57

 

 

 

 

 

WATTS

365

445

500

535

475

 

 

 

 

CFM

1360

1390

1400

1350

1180

 

HIGH

OFF

OFF

TEMP. RISE

50

49

49

51

58

 

 

 

 

WATTS

355

450

520

535

465

NOTES:

** Factory setting

8

Pub. No. 22-1682-05-0802 (EN)

Image 8
Contents Upflow/Horizontal Two-stage Condensing Gas-Fired Furnace General Features Contents Features Benefits XV 90 Standard EquipmentOptional Equipment TAYSTAT241TUY-R9V Product SPECIFICATIONS1 General DataPerformance Data Tons 1030 1450 Schematic Diagrams for GAS Furnaces Electrical DataField Wiring Diagram for 2 Stage Heating Thermostat Field WiringField Wiring Diagram for Single Stage Heating Field From Dwg B341128 Rev Pub. No -1682-05-0802 EN Dimensions Trane

100, 120R9V, XV 90, 080 specifications

The Trane XV 90, 100, 120R9V, and 080 are part of Trane's exceptional range of high-efficiency gas furnaces, designed to deliver optimal heating performance while minimizing energy consumption. These models are synonymous with reliability, comfort, and innovative technology, making them ideal for residential heating requirements.

One of the standout features of the Trane XV series is its variable-speed blower motor. This technology allows for precise adjustments to airflow, leading to more consistent temperatures throughout the home. The variable speed operation reduces noise levels, making for a quieter heating experience, and enhances energy efficiency by operating at lower settings for most of the heating cycle.

Another key characteristic of the Trane XV models is their impressive AFUE (Annual Fuel Utilization Efficiency) ratings. With efficiencies reaching up to 97%, these furnaces use significantly less fuel than traditional models, resulting in lower utility bills and reduced environmental impact. This high efficiency is achieved through a two-stage heating process, which allows the furnace to run at a lower stage for longer periods when less heating is needed.

The Trane XV series furnaces also feature integrated communicating technology. This allows the unit to seamlessly connect with other Trane smart home products and thermostats, providing users with greater control over their indoor climate. Homeowners can easily monitor and manage their heating system from anywhere, ensuring maximum comfort and efficiency.

Durability is another hallmark of Trane's engineering excellence. The XV models are designed with rugged components, including a fully insulated cabinet that minimizes heat loss and prevents cold drafts. The trapezoidal heat exchanger is engineered for longevity, while the corrosion-resistant materials used in construction ensure the furnace will withstand harsh environmental conditions for years.

Safety is paramount in the design of the Trane XV models. They come equipped with advanced safety features, including an electronic control board that monitors the system for any irregularities, ensuring reliable operation and peace of mind.

In summary, the Trane XV 90, 100, 120R9V, and 080 gas furnaces are a testament to advanced heating technology. With variable-speed blower motors, high AFUE ratings, smart connectivity, durability, and safety features, these models provide efficient and effective heating solutions tailored to modern living. Homeowners can invest in comfort with the assurance of quality and innovation that Trane is known for.