Trane XV 90, 080, 120R9V, 100 manual 1030

Page 9

Performance

Data

TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

OUTDOOR

AIRFLOW

 

DIP SWITCH SETTING

 

 

 

EXTERNAL STATIC PRESSURE

 

UNIT SIZE

SETTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW 1

 

SW 2

SW 3

 

SW 4

 

0.1

 

0.3

0.5

0.7

 

0.9

(TONS)

(See Notes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

ON

OFF

 

ON

CFM

1040

 

1040

1040

1030

 

1030

 

(350 CFM/TON)

 

 

WATTS

165

 

220

270

320

 

375

 

 

 

 

 

 

 

 

 

3.0

NORMAL

ON

 

ON

OFF

 

OFF

CFM

1210

 

1210

1230

1230

 

1230

(400 CFM/TON)

 

 

WATTS

235

 

285

360

415

 

475

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

ON

ON

 

OFF

CFM

1340

 

1370

1400

1390

 

1370

 

(450 CFM/TON)

 

 

WATTS

390

 

390

465

525

 

580

 

 

 

 

 

 

 

 

 

 

LOW

OFF

 

ON

OFF

 

ON

CFM

1200

 

1220

1230

1250

 

1230

 

(350 CFM/TON)

 

 

WATTS

225

 

280

365

425

 

485

 

 

 

 

 

 

 

 

 

3.5

NORMAL

OFF

 

ON

OFF

 

OFF

CFM

1390

 

1430

1430

1430

 

1400

(400 CFM/TON)

 

 

WATTS

335

 

425

495

560

 

590

 

 

 

 

 

 

 

 

 

 

HIGH

OFF

 

ON

ON

 

OFF

CFM

1590

 

1590

1590

1580

 

1420

 

(450 CFM/TON)

 

 

WATTS

490

 

575

625

685

 

615

 

 

 

 

 

 

 

 

 

 

LOW

ON

 

OFF

OFF

 

ON

CFM

1370

 

1420

1430

1340

 

1410

 

(350 CFM/TON)

 

 

WATTS

325

 

415

490

550

 

595

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.0

NORMAL

ON

 

OFF

OFF

 

OFF

CFM

1640

 

1640

1640

1590

 

1420

(400 CFM/TON)

 

 

WATTS

515

 

585

655

680

 

615

 

 

 

 

 

 

 

 

 

 

HIGH

ON

 

OFF

ON

 

OFF

CFM

1840

 

1840

1770

1630

 

1470

 

(450 CFM/TON)

 

 

WATTS

700

 

780

795

725

 

655

 

 

 

 

 

 

 

 

 

NOTES: Continuous Fan is with Thermostat Fan Switch on and Dip Switches 5 and 6 in the "ON" position.

1.At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.

2.LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;

NORMAL airflow (400 cfm/ton) is typical setting;

HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.

TUY100R9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER

 

 

 

 

 

1st Stage Capacity =

62,000

 

 

 

 

 

 

 

2nd Stage Capacity =

93,000

 

 

 

AIRFLOW

DIP SWITCH SETTING

 

 

EXTERNAL STATIC PRESSURE

 

 

SETTING

SW 7

SW 8

 

0.1

0.3

0.5

0.7

0.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

920

920

920

920

920

 

LOW

ON

ON

TEMP. RISE

60

60

60

60

60

 

 

 

 

WATTS

130

180

220

280

320

 

 

 

 

CFM

1020

1020

1020

1010

1000

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

54

54

54

55

56

 

 

 

WATTS

165

220

260

310

365

1ST

 

 

 

 

 

 

CFM

1160

1160

1160

1160

1150

STAGE

 

 

 

NORMAL **

ON

OFF

TEMP. RISE

48

48

48

48

48

 

 

 

 

 

WATTS

220

260

325

390

430

 

 

 

 

CFM

1350

1380

1400

1400

1390

 

HIGH

OFF

OFF

TEMP. RISE

41

40

40

40

40

 

 

 

 

WATTS

320

400

470

540

585

 

 

 

 

CFM

1290

1290

1330

1340

1320

 

LOW

ON

ON

TEMP. RISE

67

67

65

64

65

 

 

 

 

WATTS

275

355

430

490

545

 

 

 

 

CFM

1410

1460

1460

1460

1370

HEATING

MEDIUM LOW

OFF

ON

TEMP. RISE

61

59

59

59

63

 

 

 

WATTS

3561

455

520

590

590

2ND

 

 

 

 

 

 

CFM

1640

1640

1640

1600

1410

STAGE

 

 

 

NORMAL **

ON

OFF

TEMP. RISE

53

53

53

54

61

 

 

 

 

 

WATTS

530

590

660

695

620

 

 

 

 

CFM

1970

1920

1780

1660

1520

 

HIGH

OFF

OFF

TEMP. RISE

44

45

48

52

57

 

 

 

 

WATTS

855

895

820

760

695

NOTES:

** Factory setting

Pub. No. 22-1682-05-0802 (EN)

9

Image 9
Contents Upflow/Horizontal Two-stage Condensing Gas-Fired Furnace General Features Contents XV 90 Standard Equipment Features BenefitsTAYSTAT241 Optional EquipmentGeneral Data TUY-R9V Product SPECIFICATIONS1Performance Data Tons 1030 1450 Electrical Data Schematic Diagrams for GAS FurnacesField Wiring Field Wiring Diagram for Single Stage HeatingField Wiring Diagram for 2 Stage Heating Thermostat Field From Dwg B341128 Rev Pub. No -1682-05-0802 EN Dimensions Trane

100, 120R9V, XV 90, 080 specifications

The Trane XV 90, 100, 120R9V, and 080 are part of Trane's exceptional range of high-efficiency gas furnaces, designed to deliver optimal heating performance while minimizing energy consumption. These models are synonymous with reliability, comfort, and innovative technology, making them ideal for residential heating requirements.

One of the standout features of the Trane XV series is its variable-speed blower motor. This technology allows for precise adjustments to airflow, leading to more consistent temperatures throughout the home. The variable speed operation reduces noise levels, making for a quieter heating experience, and enhances energy efficiency by operating at lower settings for most of the heating cycle.

Another key characteristic of the Trane XV models is their impressive AFUE (Annual Fuel Utilization Efficiency) ratings. With efficiencies reaching up to 97%, these furnaces use significantly less fuel than traditional models, resulting in lower utility bills and reduced environmental impact. This high efficiency is achieved through a two-stage heating process, which allows the furnace to run at a lower stage for longer periods when less heating is needed.

The Trane XV series furnaces also feature integrated communicating technology. This allows the unit to seamlessly connect with other Trane smart home products and thermostats, providing users with greater control over their indoor climate. Homeowners can easily monitor and manage their heating system from anywhere, ensuring maximum comfort and efficiency.

Durability is another hallmark of Trane's engineering excellence. The XV models are designed with rugged components, including a fully insulated cabinet that minimizes heat loss and prevents cold drafts. The trapezoidal heat exchanger is engineered for longevity, while the corrosion-resistant materials used in construction ensure the furnace will withstand harsh environmental conditions for years.

Safety is paramount in the design of the Trane XV models. They come equipped with advanced safety features, including an electronic control board that monitors the system for any irregularities, ensuring reliable operation and peace of mind.

In summary, the Trane XV 90, 100, 120R9V, and 080 gas furnaces are a testament to advanced heating technology. With variable-speed blower motors, high AFUE ratings, smart connectivity, durability, and safety features, these models provide efficient and effective heating solutions tailored to modern living. Homeowners can invest in comfort with the assurance of quality and innovation that Trane is known for.