3.2.1 Setting the Start Address

Each Pelco CM9760-IRC unit requires a six-bit start address. The start address is configured using the DIP switches on the communication card (see Figure 5: DIP switches). Each control card occupies one address space. An IRC unit occupies four address spaces (if there are only two control cards in the unit, it still occupies four address spaces).

The start address of an IRC unit is set with the DIP switches on the communication card per Table B.

 

 

 

Table B.

Start Addresses

 

 

 

 

 

 

 

 

 

 

DIP

DIP

DIP

DIP

DIP

DIP

Start Address

Start Address

Switch 8

Switch 7

Switch 6

Switch 5

Switch 4

Switch 3

(Binary)

(Decimal)

 

 

 

 

 

 

 

 

ON

ON

ON

ON

ON

ON

000000

0

 

 

 

 

 

 

 

 

ON

ON

ON

ON

ON

OFF

000001

1

 

 

 

 

 

 

 

 

ON

OFF

ON

ON

ON

ON

010000

16

 

 

 

 

 

 

 

 

ON

OFF

ON

ON

OFF

ON

010010

18

 

 

 

 

 

 

 

 

OFF

OFF

ON

ON

OFF

ON

110010

50

 

 

 

 

 

 

 

 

OFF

OFF

OFF

OFF

OFF

ON

111110

62

 

 

 

 

 

 

 

 

NOTE: It is necessary only to set the start address of the IRC as a whole. The start address of each control card in the unit is set by internal de- fault.

Unlike an IRC unit, a serial GPI occupies one address space. In the sample system outlined in Figure 3, the start addresses would set up according to Table C.

 

 

 

Table C.

Start Addresses

 

 

 

 

 

 

 

Device

 

Address

(Decimal)

Address (Binary)

 

 

 

 

 

 

 

Serial GPI

 

 

0

000000

Set via serial GPI communication

 

 

 

 

 

card DIP switches

 

 

 

 

 

 

IRC unit 1/control card 1

 

 

1

000001

Set via IRC unit 1 communication

 

 

 

 

 

card DIP switches

 

 

 

 

 

 

Control card 2

 

 

2

000010

Automatic internal default

 

 

 

 

 

 

Control card 3

 

 

3

000011

Automatic internal default

 

 

 

 

 

 

Control card 4

 

 

4

000100

Automatic internal default

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pelco Manual C544M (2/98)

9

Image 10
Contents D E N D U M CM9760-IRC Infrared VCR Controller Installation C544M 2/98 Contents General Important Safeguards and WarningsProduct and/or manual may bear the following marks Description CM9760-IRC Rear ViewGeneral Features VCR Hook-up ParametersSample System Pelco CM9760-IRCInstallation Communication CardSetting the Baud Control CardSetting the Start Address Table BConnecting the CM9760-IRC to the CM9760-CC1 Host VIA CableConnecting Additional IRCs in Sequence RS-422 DB9 Port Female OUT Connect VIA CableConnecting VCRs to the Video Matrix BAY CM9760-MXB Connecting VCRs to the CM9760-MXB Video Matrix BayVCR Control Signal Outputs Transmitting VCR CommandsSpecifications Electrical SpecificationsPelco Manual C544M 2/98 Warranty and Return Information Warranty