2 MAKE WATER SUPPLY CONNECTIONS
Turn off hot and cold water supplies before beginning.
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies. Connection on fitting supplies are 3/8" compression. Connect left supply (Marked with a Red Stripe) to Hot and right supply (Marked with Blue Stripe) to Cold wall supply. Use adjustable wrench to tighten connections. Do not over tighten.
Faucet supplies are
Note: If additional supply length is required, installer must purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are too long, loop as illustrated to avoid kinking.
B L U E
R E D S T R I P E S T R I P E
2
1 COLD
HOT
3 CONNECT HOSE SPRAY and INSTALL WEIGHT
Check that seal washers are installed in both ends of SPRAY HOSE ADAPTER (1).
Thread SPRAY HOSE ADAPTER (1) onto faucet SHANK (2). Tighten with adjustable wrench.Figure 1.
Thread HOSE END (3) into bottom of SPRAY HOSE ADAPTER (1). Tighten with adjustable wrench. Make sure all connections are tight. Figure 1.
Install RUBBER BUSHING (4) onto SPRAY HOSE (5). Install WEIGHTS (6) onto HOSE (5) using two screws (7). Locate WEIGHTS (6) 18" from underside of mounting surface on HOSE (5). Tighten SCREWS (5) firmly. Figure 2.
UNDER SIDE
OF MOUNTING
SURFACE
2 SEAL WASHER
1
18"
| 3 | SEAL |
Figure 1 | WASHER | |
|
|
6
4
5 7