CLEANING INSTRUCTIONS

Failure to perform the necessary cleaning steps will damage unit.

1.Before cleaning, set CONTROLS to “OFF” position and unplug unit.

2.Remove water tank from humidifier base, and drain water from tank.

3.Allow at least 15 minutes for the hot water to cool after shutting unit “OFF” before moving base, or removing mineral absorption pad. Remove mineral absorption pad from hot water reservoir using tweezers or tongs to prevent burns from hot water. When the cleaning procedure is completed, replace mineral absorption pad. To drain water from humidifier base, grasp with both hands and tilt to the side, draining water into the sink. BE CAREFUL NOT TO HAVE DRAINING WATER FALL INTO CONTROLS OR VENT OPENINGS. DO NOT drain in any manner other than indicated. WARN- ING: DO NOT place directly under running faucet. Turn the base upside down and remove the cap by turning it counterclockwise. Clean out any for- eign matter that has accumulated inside the fitting from which the cap was removed. After cleaning, replace this cap tightly by hand. Pour a small amount of water into the hot water reservoir and check for leaks from this cap under the base.

4.Pour about 1 cup of white vinegar into either reservoir and allow it to soak for only 20 to 30 minutes.

5.Hold the base of the humidifier over the sink and tilt it on its side to empty the vinegar. Fill the cold and hot water reservoirs with clean, warm water to remove all traces of the vinegar. Remove any buildup of minerals in the hot water reservoir using a small brush, such as a toothbrush. NOTE: The buildup is due to water hardness. The harder your water, the more often this maintenance will be needed. Empty all of this water by turning the unit on its side.

DO NOT ALLOW WATER TO ENTER THE BOTTOM OF THE HUMIDIFIER BASE OR ANY OTHER OPENINGS, OR IMMERSE THE CORD AND PLUG.

6.Disinfect the water tank using a solution of one teaspoon of household chlo- rine bleach in 1 gallon of water. Let the solution sit for 20 minutes, swishing every few minutes to wet all surfaces. Empty the tank completely; rinse thoroughly until all of the bleach smell is gone. Fill the tank with fresh, cool water and replace it onto the humidifier base.

7.NEVER use any metal or hard objects to clean plastic parts which may cause scratching of the plastic parts. NEVER use gasoline, kerosene, glass cleaner, furniture polish, paint thinner or other household solvents to clean any part of the humidifier.

8.Each day the reservoir and tank should be drained, rinsed and refilled with fresh tap water.

7

Image 7
Contents Read and Save These Instructions Important Safeguards Place unit in an area where it is not accessible to children Power Control Panel POWER/MODEHumidity Operating Instructions Replace UV BulbFilling the Water Tank Cleaning and Maintenance Using the Medication CUP/MIST Outlet Grille OptionalMineral Absorption PAD Instructions Cleaning Instructions Changing the UV Bulb Troubleshooting ServiceStorage Tips Important Notice Limited Warranty

GF-211D specifications

The Slant/Fin GF-211D is a powerful and efficient gas-fired boiler designed for residential heating applications. This model exemplifies modern heating technology, offering both efficiency and reliability to homeowners. One of the standout features of the GF-211D is its exceptional heating output, making it suitable for various home sizes and heating demands. With a high BTU rating, it ensures that even larger homes can maintain a comfortable temperature during the coldest months of the year.

A central characteristic of the Slant/Fin GF-211D is its advanced design, which incorporates a cast-iron heat exchanger. This component is known for its durability and excellent heat retention capabilities, allowing the boiler to operate efficiently while providing consistent heat. The cast-iron construction also contributes to the longevity of the unit, minimizing the risk of wear and tear over time.

Another notable feature is the GF-211D’s utilization of a low-water cut-off. This technology enhances safety by preventing the boiler from operating when water levels are too low, protecting against potential damage. Additionally, the integrated venting system is designed for maximum efficiency, allowing for easy installation and reducing the risk of heat loss.

The Slant/Fin GF-211D boasts an Energy Star rating, highlighting its commitment to energy efficiency. Homeowners can expect lower energy bills and reduced environmental impact when utilizing this boiler. The unit is compatible with various heating systems, including hydronic and baseboard heating, providing versatility to meet diverse heating needs.

User-friendly controls are another hallmark of the GF-211D. The intuitive interface allows for easy adjustments to temperature settings and operation modes, empowering homeowners to optimize heating based on their specific requirements. The boiler also features multiple safety mechanisms, ensuring peace of mind during operation.

In summary, the Slant/Fin GF-211D gas-fired boiler stands out for its impressive heating capacity, durable construction, energy efficiency, and advanced safety features. Designed with modern technology in mind, it represents a dependable choice for those seeking an effective heating solution for their homes. With its combination of performance and reliability, the GF-211D is poised to deliver consistent comfort for years to come.