Slant/Fin BOILERS dimensions Burner Data Riello, Turbulator Settings Riello 40 Series

Page 17

LIBERTY II

17

BURNER DATA – RIELLO (continued)

FIgure 9B

MODEL F-10

ELECTRODE SETTING

SETTING THE AIR ADJUSTMENT PLATE (See figure 11)

1.The hydraulic AIR SHUTTER (A) is operated by the HYDRAULIC JACK (F), assuring complete opening of the combustion air intake. Regulation of the combustion air flow is made by adjustment of the manual AIR ADJUSTMENT PLATE (D) after loosening the FIXING SCREWS (C and E). The initial setting of the air adjustment plate should be made according to page 16.

2.The proper number on the manual AIR ADJUSTMENT PLATE (D) should line up with the SETTING INDICATOR (B) on the fan housing cover. Once set, the air adjustment plate should be secured in place by tightening SCREWS C and E. Manually open and release the hydraulic air shutter to ensure it has free movement.

3.The final position of the air adjustment plate will vary on each instal- lation. Use instruments to establish the proper settings for maximum

CO2 and a smoke reading of zero.

NOTE: Variations in flue gas, smoke, CO2 and temperature readings may be experienced when the burner cover is put in place. Therefore, the burner cover must be in place when making the final combustion instrument readings, to ensure proper test results.

FIgure 11

NOTE: ELECTRODES ARE PRESET AT THE FACTORY.

REGULATION OF THE TURBULATOR AND AIR SHUTTER FOR

PROPER COMBUSTION

Turbulator Setting

1.Loosen nut, 1, then turn the screw, 2, until the index marker, 3, is aligned with the correct index number.

2.Retighten the retaining nut, 1.

TURBULATOR SETTINGS - RIELLO 40 SERIES

The numbers on the casting are there to denote the high and low end of the scale — in all cases the first mark if "Zero".

The air/oil ratio depends on accurate setting of the turbulator disc.

Be careful when making this adjustment as an incorrect setting will result in an unsatisfactory installation. See figures 10A and 10B.

FIgure 10A

FIgure 12

FOR PROPER INSERTION INTO COMBUSTION CHAMBER

FIgure 10B

Image 17
Contents Liberty Liberty Boiler Location Chimney CONNECTOR-18Minimum Clearance Chimney RequirementsRequires AIR from OUT Liberty Cleaning Piping System Installing Controls Accessories on Boiler UnitsPiping Piping for Steam BoilersOIL Supply Piping Installing the BurnerWiring the Boiler START-UPCOMBUSTION Test Instruments Must be Used Cleaning and Filling a NEW Water BoilerVent Piping and Draft Regulator LOW Water CUT-OFF CHECK-OUT Cleaning and Filling a NEW Steam BoilerBlowing OFF a LOW Pressure Steam Boiler Pressure Control CHECK-OUT Replacement of Steam BoilersLiberty Basic Module Wiring Detail a Liberty Delevan Burner Data Beckett CF-375 Burners for Packaged Boilers onlyLiberty Burner Data Riello Turbulator Settings Riello 40 SeriesLiberty Liberty III. OIL Burner IV. General MaintenanceII. Providing Protection for Freezing

BOILERS specifications

Slant/Fin is a recognized leader in the manufacturing of high-quality cast iron and stainless steel boilers, providing reliable heating solutions for residential and commercial applications. With a commitment to performance and efficiency, Slant/Fin has developed a diverse range of boiler products that cater to various heating needs and preferences.

One of the key features of Slant/Fin boilers is their exceptional fuel efficiency, which is largely achieved through advanced design and engineering. Many Slant/Fin models are designed with state-of-the-art technology to maximize heat transfer while minimizing fuel consumption. This focus on efficiency not only reduces energy costs for homeowners and businesses but also contributes to environmental sustainability by lowering carbon emissions.

Another notable characteristic is the robust construction of Slant/Fin boilers. Made from high-quality materials such as cast iron and stainless steel, these boilers are built to last with impressive durability and resilience against corrosion. This construction ensures that the boilers can withstand the rigors of heating duties for many years, providing peace of mind to users regarding long-term reliability.

Slant/Fin also stands out in terms of its range of options that cater to different heating requirements. For instance, their Mod-Con series offers high-efficiency condensing technology, which captures and reuses heat from exhaust gases. This results in maximum efficiency levels of up to 96%, making these units a top choice for energy-conscious consumers.

Furthermore, Slant/Fin boilers are designed with user-friendliness in mind. Many models come equipped with advanced control systems that allow for precise temperature management, system monitoring, and easy integration with smart home technology. This means users can maintain optimal comfort levels while also managing energy consumption more effectively.

The company also prioritizes safety features in its boiler designs. Many Slant/Fin models include built-in safety controls that protect against overheating and pressure build-up, ensuring that the unit operates safely in various conditions.

In summary, Slant/Fin boilers exemplify a combination of efficiency, durability, and user-friendliness. With a variety of models tailored to meet a wide range of heating demands and a strong emphasis on safety, Slant/Fin continues to be a trusted choice for both residential and commercial heating needs. The company's innovative approach and commitment to quality ensure that customers receive superior performance and lasting value in their heating systems.