Slant/Fin BOILERS Installing Controls Accessories on Boiler Units, Cleaning Piping System

Page 6

6

LIBERTY II

INSTALLING CONTROLS AND

ACCESSORIES ON BOILER UNITS

Note: Jacket must be installed on boiler units prior to installation of trim.

I.STEAM BOILER TRIM, see page 2 for tapping locations, and figure 4 for illustration of steam boiler.

A.Steam pressure gauge and pressure cut-out, install in tapping no. 4, figure 4.

B.Gauge glass set — use tapping no. 12.

C.Pop safety valve — use tapping no. 3, piped full size to boiler; or pipe full size into a valveless steam header.

D.Combustion safety control — mounted on burner.

II.WATER BOILER TRIM, see page 2 for tapping locations, and fig- ures 1 and 2 for illustration of water boiler.

A.Pressure- temperature - altitude gauge — use tapping no. 6.

B.High temperature limit — use tapping no. 7.

C.Operating control (if used) — use tapping no. 7.

D.Water relief valve — use tapping no. 3, piped full size to boiler.

E.Automatic air vent or compression tank tappings — if used, install in tapping no. 2.

F.Combustion safety control — mounted on burner.

PIPING

IMPORTANT: Boilers are to be used with closed system. Any application that uses steam or water from system, causes the intro- duction of a frequent supply of fresh water into the boiler. This will cause damage to the boiler. Use of heat exchangers will prevent this damage.

PIPING FOR STEAM BOILERS

Provide Header and Hartford Loop as suggested. See figures 4 and 5. Local codes apply.

CLEANING PIPING SYSTEM

A.To clean piping system, open all valves at the heating elements. After getting up a good head of steam, shut the boiler down and allow the condensate to return to the boiler. The condensate will carry the oil film with it. Again blow-off the boiler. On extremely fouled systems, it may require several visits over a few days to clean

the system.

B.When steam only (no water) is released through the hand valve, the boiler will not surge or flood.

PIPING FOR WATER UNITS

NOTE: On knocked-down boiler only, jacket may be installed after sup- ply and return piping connection, but must be installed prior to adding trim.

I.CIRCULATING SYSTEM

A.FORCED CIRCULATION hot water heating system: Use the top tapping as supply tapping, and use the front or rear bottom tappings for the return.

B.A FLOW CONTROL VALVE (See figure 6) will prevent gravity

circulation and usually is required when tankless heater is installed.

II.AIR CONTROL SYSTEMS

A.DIAPHRAGM-TYPE COMPRESSION TANKS are used to con- trol system pressure in an AIR ELIMINATING SYSTEM:

an automatic air vent is used to REMOVE air from the system water.See figure 6. If system pressure needs further control, add an additional tank or install a larger capacity tank. The automatic air vent should be installed in the top of the boiler, as in figure 6.

B.CONVENTIONAL COMPRESSION TANKS (non-diaphragm type) are used to control system pressure in an AIR COLLECTING SYSTEM. Within the system, after initial start-up and venting, air is collected in the tank and acts in contact with the water to con- trol pressure. Air is not vented from this system.

If system pressure needs further control, add another tank in parallel with the original tank or install a large capacity tank. Locate the tank at the inlet end of the pump near the boiler.

(See figure 7)

Image 6
Contents Liberty Liberty Minimum Clearance Chimney CONNECTOR-18Boiler Location Chimney RequirementsRequires AIR from OUT Liberty Piping Installing Controls Accessories on Boiler UnitsCleaning Piping System Piping for Steam BoilersInstalling the Burner Wiring the BoilerOIL Supply Piping Cleaning and Filling a NEW Water Boiler Vent Piping and Draft RegulatorSTART-UPCOMBUSTION Test Instruments Must be Used Cleaning and Filling a NEW Steam Boiler Blowing OFF a LOW Pressure Steam BoilerLOW Water CUT-OFF CHECK-OUT Replacement of Steam Boilers Pressure Control CHECK-OUTLiberty Basic Module Wiring Detail a Liberty Burner Data Beckett CF-375 Burners for Packaged Boilers only DelevanLiberty Turbulator Settings Riello 40 Series Burner Data RielloLiberty Liberty IV. General Maintenance II. Providing Protection for FreezingIII. OIL Burner

BOILERS specifications

Slant/Fin is a recognized leader in the manufacturing of high-quality cast iron and stainless steel boilers, providing reliable heating solutions for residential and commercial applications. With a commitment to performance and efficiency, Slant/Fin has developed a diverse range of boiler products that cater to various heating needs and preferences.

One of the key features of Slant/Fin boilers is their exceptional fuel efficiency, which is largely achieved through advanced design and engineering. Many Slant/Fin models are designed with state-of-the-art technology to maximize heat transfer while minimizing fuel consumption. This focus on efficiency not only reduces energy costs for homeowners and businesses but also contributes to environmental sustainability by lowering carbon emissions.

Another notable characteristic is the robust construction of Slant/Fin boilers. Made from high-quality materials such as cast iron and stainless steel, these boilers are built to last with impressive durability and resilience against corrosion. This construction ensures that the boilers can withstand the rigors of heating duties for many years, providing peace of mind to users regarding long-term reliability.

Slant/Fin also stands out in terms of its range of options that cater to different heating requirements. For instance, their Mod-Con series offers high-efficiency condensing technology, which captures and reuses heat from exhaust gases. This results in maximum efficiency levels of up to 96%, making these units a top choice for energy-conscious consumers.

Furthermore, Slant/Fin boilers are designed with user-friendliness in mind. Many models come equipped with advanced control systems that allow for precise temperature management, system monitoring, and easy integration with smart home technology. This means users can maintain optimal comfort levels while also managing energy consumption more effectively.

The company also prioritizes safety features in its boiler designs. Many Slant/Fin models include built-in safety controls that protect against overheating and pressure build-up, ensuring that the unit operates safely in various conditions.

In summary, Slant/Fin boilers exemplify a combination of efficiency, durability, and user-friendliness. With a variety of models tailored to meet a wide range of heating demands and a strong emphasis on safety, Slant/Fin continues to be a trusted choice for both residential and commercial heating needs. The company's innovative approach and commitment to quality ensure that customers receive superior performance and lasting value in their heating systems.