9 TEST INSTALLED FITTING
4
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
1
Operate both HANDLES (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate
1
3
Release
if necessary.
5
WASTE
OUTLET
| 2 |
| 2 |
|
| “P” TRAP | |
10 | INSTALLATION OF OPTIONAL METAL LEVER HANDLES |
| 7 |
(Supplied with Faucet) |
| 5 | |
Thread PORCELIAN LEVER HANDLE (2) | 2 | 4 | |
|
| ||
and remove INDEX BUTTON with MOUNTING ROD ASSEMBLY (1), |
| 3 | |
HANDLE COLLAR (4) and |
| ||
|
| ||
Insert MOUNTING ROD ASSEMBLY (1) into METAL HANDLE (3), | 1 |
| |
HANDLE COLLAR (4) and |
| ||
Thread HANDLE ASSEMBLY (6) into ball of HANDLE BASE (7). |
|
| |
Apply pressure to the MOUNTING ROD ASSEMBLY (1) |
|
| |
while turning the HANDLE COLLAR (4), in order to tighten |
| 6 | |
firmly. |
|
|
11 SERVICE | 90 |
|
STOP |
| |
| WASHER |
|
To change direction of handle rotation, |
| |
proceed as follows: |
|
|
Turn valve to OFF position. |
|
|
Pull out INDEX CAP and remove |
|
|
HANDLE SCREW. |
|
|
Remove SPRING CLIP. |
|
|
Lift STOP WASHER, turn 90˚ and replace. |
| |
Replace SPRING CLIP. |
| SPRING |
Replace ADAPTER, HANDLE, SCREW, and INDEX CAP. | CLIP |
AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and rinse clean.
If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.
ALIGN HANDLES
Pull out INDEX CAP (1) and remove HANDLE SCREW (2), HANDLE (3) and ADAPTER (4).
Push ADAPTER (4) on VALVE STEM (5). Find correct position of HANDLE (3) by adjusting male teeth on ADAPTER (4) to female teeth on HANDLE (3).
Replace HANDLE SCREW (2) and push in INDEX CAP (1).
1
2
3
4
5
12 CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
M968423 Rev . 1 . 2
4